insert into Sys_Menu(MenuId,MenuName,Url,SortIndex,SuperMenu,MenuModule) values('12033BD1-4326-4841-8A2C-B173F4D963F8','试压包检查尾项清单','SYBData/FinalitemList.aspx',220,'3EAFF140-E5CA-4978-B83D-D2C9F36E0D52','3') go insert into ButtonToMenu(ButtonToMenuId,MenuId,ButtonName,SortIndex) values('EB9543A2-D9D5-4935-95D3-B607F35D1849','12033BD1-4326-4841-8A2C-B173F4D963F8','增加',1) insert into ButtonToMenu(ButtonToMenuId,MenuId,ButtonName,SortIndex) values('32C41FC2-715E-404B-8C16-73930EC7DB88','12033BD1-4326-4841-8A2C-B173F4D963F8','修改',2) insert into ButtonToMenu(ButtonToMenuId,MenuId,ButtonName,SortIndex) values('BC8F3EFE-C09F-4756-B010-3C0A1AD3B258','12033BD1-4326-4841-8A2C-B173F4D963F8','删除',3) insert into ButtonToMenu(ButtonToMenuId,MenuId,ButtonName,SortIndex) values('C0EC20CC-B84C-419E-9BA0-F7BCD58845B1','12033BD1-4326-4841-8A2C-B173F4D963F8','保存',4) go CREATE TABLE [dbo].[SYBData_FinalitemList]( [FinalitemListId] [nvarchar](50) NOT NULL, [ProjectId] [nvarchar](50) NULL, [IndividualProject] [nvarchar](50) NULL, [PipeSectionCode] [nvarchar](50) NULL, [FinalItemContent] [nvarchar](200) NULL, [SD_ConUnit] [nvarchar](50) NULL, [SD_SupervisionUnit] [nvarchar](50) NULL, [SD_OwnerUnit] [nvarchar](50) NULL, CONSTRAINT [PK_SYBData_FinalitemList] PRIMARY KEY CLUSTERED ( [FinalitemListId] ASC )WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON, OPTIMIZE_FOR_SEQUENTIAL_KEY = OFF) ON [PRIMARY] ) ON [PRIMARY] GO ALTER TABLE [dbo].[SYBData_FinalitemList] WITH CHECK ADD CONSTRAINT [FK_SYBData_FinalitemList_Base_Project] FOREIGN KEY([ProjectId]) REFERENCES [dbo].[Base_Project] ([ProjectId]) GO ALTER TABLE [dbo].[SYBData_FinalitemList] CHECK CONSTRAINT [FK_SYBData_FinalitemList_Base_Project] GO EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'主键' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SYBData_FinalitemList', @level2type=N'COLUMN',@level2name=N'FinalitemListId' GO EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'项目Id' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SYBData_FinalitemList', @level2type=N'COLUMN',@level2name=N'ProjectId' GO EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'单项工程名称' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SYBData_FinalitemList', @level2type=N'COLUMN',@level2name=N'IndividualProject' GO EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'试压包管段号' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SYBData_FinalitemList', @level2type=N'COLUMN',@level2name=N'PipeSectionCode' GO EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'尾项内容' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SYBData_FinalitemList', @level2type=N'COLUMN',@level2name=N'FinalItemContent' GO EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'销项确认-施工单位' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SYBData_FinalitemList', @level2type=N'COLUMN',@level2name=N'SD_ConUnit' GO EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'销项确认-监理单位' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SYBData_FinalitemList', @level2type=N'COLUMN',@level2name=N'SD_SupervisionUnit' GO EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'销项确认-业主单位' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SYBData_FinalitemList', @level2type=N'COLUMN',@level2name=N'SD_OwnerUnit' GO EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'管道系统试压尾项清单' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'SYBData_FinalitemList' GO