173 lines
9.9 KiB
Transact-SQL
173 lines
9.9 KiB
Transact-SQL
|
||
update Sys_Menu set Url='HJGL/MaterialManage/ElectrodeBakeRecordNew.aspx' where MenuId='B255A0C2-3D63-4A25-6666-FA8F37F22361'
|
||
go
|
||
update Sys_Menu set Url='HJGL/MaterialManage/EWeldRHRecordNew.aspx' where MenuId='5BADA90D-EB19-47DE-6666-CA22517AF415'
|
||
go
|
||
insert into Sys_Menu(MenuId,MenuName,Url,SortIndex,SuperMenu,MenuModule)
|
||
values('53923748-0DD6-4DF9-A307-866B64F1F36B','º¸¼Áºæ¿¾¼Ç¼','HJGL/MaterialManage/SolderBakingRecordProject.aspx',15,'4105B536-E0E9-4CD3-6666-27BB147603FA','3')
|
||
go
|
||
insert into ButtonToMenu(ButtonToMenuId,MenuId,ButtonName,SortIndex)
|
||
values('1981693C-FF64-4AA4-AAF9-C78C86B08796','53923748-0DD6-4DF9-A307-866B64F1F36B','±£´æ',1)
|
||
insert into ButtonToMenu(ButtonToMenuId,MenuId,ButtonName,SortIndex)
|
||
values('F8E5683A-9979-4909-BB20-23153996D7F9','53923748-0DD6-4DF9-A307-866B64F1F36B','ɾ³ý',2)
|
||
go
|
||
|
||
CREATE TABLE [dbo].[HJGL_BakeRecordsProject](
|
||
[BakeRecordsProjectId] [nvarchar](50) NOT NULL,
|
||
[ProjectId] [nvarchar](50) NOT NULL,
|
||
[BakeDate] [datetime] NULL,
|
||
[Brand] [nvarchar](50) NULL,
|
||
[BatchNum] [nvarchar](50) NULL,
|
||
[InboundSelfNum] [nvarchar](50) NULL,
|
||
[Specifications] [nvarchar](50) NULL,
|
||
[Quantity] [decimal](18, 2) NULL,
|
||
[PowerTime] [datetime] NULL,
|
||
[PowerTemperature] [decimal](18, 1) NULL,
|
||
[ConstantTemperature] [decimal](18, 1) NULL,
|
||
[ConstantStartTime] [datetime] NULL,
|
||
[ConstantEndTime] [datetime] NULL,
|
||
[MoveInsulationBoxTime] [datetime] NULL,
|
||
[MoveInsulationBoxTemperature] [decimal](18, 1) NULL,
|
||
[BakingFrequency] [int] NULL,
|
||
[Bakers] [nvarchar](50) NULL,
|
||
[UnitStoreId] [nvarchar](50) NULL,
|
||
[Type] [char](1) NULL,
|
||
[BakeRecordsId] [nvarchar](50) NULL,
|
||
CONSTRAINT [PK_HJGL_BakeRecordsProject] PRIMARY KEY CLUSTERED
|
||
(
|
||
[BakeRecordsProjectId] ASC
|
||
)WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY]
|
||
) ON [PRIMARY]
|
||
GO
|
||
|
||
ALTER TABLE [dbo].[HJGL_BakeRecordsProject] WITH CHECK ADD CONSTRAINT [FK_HJGL_BakeRecordsProject_Base_Project] FOREIGN KEY([ProjectId])
|
||
REFERENCES [dbo].[Base_Project] ([ProjectId])
|
||
GO
|
||
|
||
ALTER TABLE [dbo].[HJGL_BakeRecordsProject] CHECK CONSTRAINT [FK_HJGL_BakeRecordsProject_Base_Project]
|
||
GO
|
||
|
||
ALTER TABLE [dbo].[HJGL_BakeRecordsProject] WITH CHECK ADD CONSTRAINT [FK_HJGL_BakeRecordsProject_HJGL_BakeRecords] FOREIGN KEY([BakeRecordsId])
|
||
REFERENCES [dbo].[HJGL_BakeRecords] ([BakeRecordsId])
|
||
GO
|
||
|
||
ALTER TABLE [dbo].[HJGL_BakeRecordsProject] CHECK CONSTRAINT [FK_HJGL_BakeRecordsProject_HJGL_BakeRecords]
|
||
GO
|
||
|
||
ALTER TABLE [dbo].[HJGL_BakeRecordsProject] WITH CHECK ADD CONSTRAINT [FK_HJGL_BakeRecordsProject_Weld_UnitStore] FOREIGN KEY([UnitStoreId])
|
||
REFERENCES [dbo].[Weld_UnitStore] ([UnitStoreId])
|
||
GO
|
||
|
||
ALTER TABLE [dbo].[HJGL_BakeRecordsProject] CHECK CONSTRAINT [FK_HJGL_BakeRecordsProject_Weld_UnitStore]
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'Ö÷¼ü' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'BakeRecordsProjectId'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÏîÄ¿Id' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'ProjectId'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ºæ¿¾ÈÕÆÚ' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'BakeDate'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÅÆºÅ' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'Brand'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÅúºÅ' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'BatchNum'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'Èë¿â×Ô±àºÅ' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'InboundSelfNum'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'¹æ¸ñmm' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'Specifications'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÊýÁ¿kg' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'Quantity'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ºæÏäË͵çʱ¼ä' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'PowerTime'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ºæÏäË͵çζÈ' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'PowerTemperature'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ºãÎÂζÈ' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'ConstantTemperature'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ºãοªÊ¼Ê±¼ä' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'ConstantStartTime'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ºãνáÊøÊ±¼ä' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'ConstantEndTime'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÒÆÈë±£ÎÂÏäʱ¼ä' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'MoveInsulationBoxTime'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÒÆÈë±£ÎÂÏäζÈ' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'MoveInsulationBoxTemperature'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ºæ¿¾´ÎÊý' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'BakingFrequency'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ºæ¿¾ÈË' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'Bakers'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'µ¥Î»²Ö¿âId' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'UnitStoreId'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'1-º¸Ìõºæ¿¾¼Ç¼£¬2-º¸¼Áºæ¿¾¼Ç¼' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject', @level2type=N'COLUMN',@level2name=N'Type'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'º¸Ìõ¡¢º¸¼Áºæ¿¾¼Ç¼' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_BakeRecordsProject'
|
||
GO
|
||
|
||
|
||
|
||
CREATE TABLE [dbo].[HJGL_TemperatureAndHumidityProject](
|
||
[TemperatureAndHumidityProjectId] [nvarchar](50) NOT NULL,
|
||
[ProjectId] [nvarchar](50) NOT NULL,
|
||
[RecordDate] [datetime] NULL,
|
||
[Temperature] [decimal](18, 1) NULL,
|
||
[Humidity] [decimal](18, 1) NULL,
|
||
[RecordMan] [nvarchar](50) NULL,
|
||
[TemperatureAndHumidityId] [nvarchar](50) NULL,
|
||
CONSTRAINT [PK_HJGL_TemperatureAndHumidityProject] PRIMARY KEY CLUSTERED
|
||
(
|
||
[TemperatureAndHumidityProjectId] ASC
|
||
)WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY]
|
||
) ON [PRIMARY]
|
||
GO
|
||
|
||
ALTER TABLE [dbo].[HJGL_TemperatureAndHumidityProject] WITH CHECK ADD CONSTRAINT [FK_HJGL_TemperatureAndHumidityProject_Base_Project] FOREIGN KEY([ProjectId])
|
||
REFERENCES [dbo].[Base_Project] ([ProjectId])
|
||
GO
|
||
|
||
ALTER TABLE [dbo].[HJGL_TemperatureAndHumidityProject] CHECK CONSTRAINT [FK_HJGL_TemperatureAndHumidityProject_Base_Project]
|
||
GO
|
||
|
||
ALTER TABLE [dbo].[HJGL_TemperatureAndHumidityProject] WITH CHECK ADD CONSTRAINT [FK_HJGL_TemperatureAndHumidityProject_HJGL_TemperatureAndHumidity] FOREIGN KEY([TemperatureAndHumidityId])
|
||
REFERENCES [dbo].[HJGL_TemperatureAndHumidity] ([TemperatureAndHumidityId])
|
||
GO
|
||
|
||
ALTER TABLE [dbo].[HJGL_TemperatureAndHumidityProject] CHECK CONSTRAINT [FK_HJGL_TemperatureAndHumidityProject_HJGL_TemperatureAndHumidity]
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'Ö÷¼ü' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_TemperatureAndHumidityProject', @level2type=N'COLUMN',@level2name=N'TemperatureAndHumidityProjectId'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'¼Ç¼ʱ¼ä' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_TemperatureAndHumidityProject', @level2type=N'COLUMN',@level2name=N'RecordDate'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ζÈ' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_TemperatureAndHumidityProject', @level2type=N'COLUMN',@level2name=N'Temperature'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ʪ¶È' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_TemperatureAndHumidityProject', @level2type=N'COLUMN',@level2name=N'Humidity'
|
||
GO
|
||
|
||
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'º¸²Ä¿âÎÂʪ¶È¼Ç¼' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'HJGL_TemperatureAndHumidityProject'
|
||
GO
|
||
|
||
|
||
alter table HJGL_BakeRecordsProject add States char(1)
|
||