diff --git a/DataBase/版本日志/SUBQHSE_V2026-10-21-xiaj.sql b/DataBase/版本日志/SUBQHSE_V2026-10-21-xiaj.sql new file mode 100644 index 00000000..31456429 --- /dev/null +++ b/DataBase/版本日志/SUBQHSE_V2026-10-21-xiaj.sql @@ -0,0 +1,57 @@ + +--Î¥ÕÂ×÷Òµ£º²¹³äÎ¥Õ¼¶±ð +IF NOT EXISTS (SELECT 1 FROM INFORMATION_SCHEMA.COLUMNS WHERE TABLE_NAME = 'SANKU_VIOLATION' AND COLUMN_NAME = 'VIOLATION_LEVEL') +BEGIN + --Î¥Õ¼¶±ð + ALTER TABLE SANKU_VIOLATION ADD VIOLATION_LEVEL varchar(20); + EXEC sp_addextendedproperty 'MS_Description', N'Î¥Õ¼¶±ð','SCHEMA', N'dbo','TABLE', N'SANKU_VIOLATION','COLUMN', N'VIOLATION_LEVEL'; +END +GO +--Òþ»¼¼Ç¼£º²¹³äÕû¸ÄÍê³Éʱ¼ä +IF NOT EXISTS (SELECT 1 FROM INFORMATION_SCHEMA.COLUMNS WHERE TABLE_NAME = 'SANKU_HAZARD' AND COLUMN_NAME = 'ECTIFICATION_COMPLETIONDATE') +BEGIN + --Õû¸ÄÍê³Éʱ¼ä + ALTER TABLE SANKU_HAZARD ADD ECTIFICATION_COMPLETIONDATE datetime; + EXEC sp_addextendedproperty 'MS_Description', N'Õû¸ÄÍê³Éʱ¼ä','SCHEMA', N'dbo','TABLE', N'SANKU_HAZARD','COLUMN', N'ECTIFICATION_COMPLETIONDATE'; +END +GO +--Σ´ó¹¤³Ì£ºµÈ¼¶¡¢×´Ì¬ +IF NOT EXISTS (SELECT 1 FROM INFORMATION_SCHEMA.COLUMNS WHERE TABLE_NAME = 'SANKU_DANGEROUS_ENGINEERING' AND COLUMN_NAME = 'ENGINEERING_LEVEL') +BEGIN + --µÈ¼¶ + ALTER TABLE SANKU_DANGEROUS_ENGINEERING ADD ENGINEERING_LEVEL varchar(20); + EXEC sp_addextendedproperty 'MS_Description', N'µÈ¼¶','SCHEMA', N'dbo','TABLE', N'SANKU_DANGEROUS_ENGINEERING','COLUMN', N'ENGINEERING_LEVEL'; + --״̬ + ALTER TABLE SANKU_DANGEROUS_ENGINEERING ADD ENGINEERING_STATE varchar(20); + EXEC sp_addextendedproperty 'MS_Description', N'״̬','SCHEMA', N'dbo','TABLE', N'SANKU_DANGEROUS_ENGINEERING','COLUMN', N'ENGINEERING_STATE'; +END +GO +--Íø¸ñ»¯Ñ²²é£ºÑ²²é´ý°ìÊÂÏѲ²é´ý°ì½ÓÊÕÈÕÆÚ +IF NOT EXISTS (SELECT 1 FROM INFORMATION_SCHEMA.COLUMNS WHERE TABLE_NAME = 'SANKU_GRID_PATROL' AND COLUMN_NAME = 'PATROL_WORKITEMS') +BEGIN + --Ѳ²é´ý°ìÊÂÏî + ALTER TABLE SANKU_GRID_PATROL ADD PATROL_WORKITEMS varchar(200); + EXEC sp_addextendedproperty 'MS_Description', N'Ѳ²é´ý°ìÊÂÏî','SCHEMA', N'dbo','TABLE', N'SANKU_GRID_PATROL','COLUMN', N'PATROL_WORKITEMS'; + --Ѳ²é´ý°ì½ÓÊÕÈÕÆÚ + ALTER TABLE SANKU_GRID_PATROL ADD PATROL_RECEIVEDATE datetime; + EXEC sp_addextendedproperty 'MS_Description', N'Ѳ²é´ý°ì½ÓÊÕÈÕÆÚ','SCHEMA', N'dbo','TABLE', N'SANKU_GRID_PATROL','COLUMN', N'PATROL_RECEIVEDATE'; +END +GO + +--select* from Sys_Const where GroupId='ViolationPersonHandleStep' + +update Sys_Const set ConstValue=5,SortIndex=5 +where GroupId='ViolationPersonHandleStep' and ConstValue=3 and ConstText='·£¿î' + + +GO + + +--ÀúÊ·Êý¾Ý´¦Àí +TRUNCATE TABLE SANKU_VIOLATION; +TRUNCATE TABLE SANKU_DANGEROUS_ENGINEERING; +TRUNCATE TABLE SANKU_GRID_PATROL; +TRUNCATE TABLE SANKU_HAZARD; + + + diff --git a/DataBase/版本日志/SUBQHSE_V2026-10-21-xiaj(SP_SANKU_DATA_INIT).sql b/DataBase/版本日志/SUBQHSE_V2026-10-21-xiaj(SP_SANKU_DATA_INIT).sql new file mode 100644 index 00000000..ec6d6b0d --- /dev/null +++ b/DataBase/版本日志/SUBQHSE_V2026-10-21-xiaj(SP_SANKU_DATA_INIT).sql @@ -0,0 +1,280 @@ + + +ALTER PROCEDURE [dbo].[SP_SANKU_DATA_INIT] + @type VARCHAR(100) = NULL, + @op TINYINT +AS +BEGIN + SET NOCOUNT ON; + DECLARE @trimType VARCHAR(100) = LTRIM(RTRIM(ISNULL(@type, ''))); + + -- op=0 Çå¿ÕÂß¼­ + IF @op = 0 + BEGIN + IF @trimType = 'SANKU_ACCIDENT_RECORD' + BEGIN + TRUNCATE TABLE SANKU_ACCIDENT_RECORD; + END + ELSE IF @trimType = 'SANKU_VIOLATION' + BEGIN + TRUNCATE TABLE SANKU_VIOLATION; + END + ELSE IF @trimType = 'SANKU_HAZARD' + BEGIN + TRUNCATE TABLE SANKU_HAZARD; + END + ELSE IF @trimType = 'SANKU_SAFETY_REWARD' + BEGIN + TRUNCATE TABLE SANKU_SAFETY_REWARD; + END + ELSE IF @trimType = 'SANKU_ADMIN_PENALTY' + BEGIN + TRUNCATE TABLE SANKU_ADMIN_PENALTY; + END + ELSE IF @trimType = 'SANKU_TRAINING' + BEGIN + TRUNCATE TABLE SANKU_TRAINING; + END + ELSE IF @trimType = 'SANKU_EXAMINATION' + BEGIN + TRUNCATE TABLE SANKU_EXAMINATION; + END + ELSE IF @trimType = 'SANKU_DANGEROUS_ENGINEERING' + BEGIN + TRUNCATE TABLE SANKU_DANGEROUS_ENGINEERING; + END + ELSE IF @trimType = 'SANKU_GRID_PATROL' + BEGIN + TRUNCATE TABLE SANKU_GRID_PATROL; + END + ELSE IF @trimType = '' -- type null/¿Õ£¬È«²¿Çå¿Õ + BEGIN + TRUNCATE TABLE SANKU_ACCIDENT_RECORD; + TRUNCATE TABLE SANKU_VIOLATION; + TRUNCATE TABLE SANKU_HAZARD; + TRUNCATE TABLE SANKU_SAFETY_REWARD; + TRUNCATE TABLE SANKU_ADMIN_PENALTY; + TRUNCATE TABLE SANKU_TRAINING; + TRUNCATE TABLE SANKU_EXAMINATION; + TRUNCATE TABLE SANKU_DANGEROUS_ENGINEERING; + TRUNCATE TABLE SANKU_GRID_PATROL; + END + END + + -- op=1 ³õʼ»¯²åÈëÂß¼­ + IF @op = 1 + BEGIN + + -- typeΪNULL/¿Õ×Ö·û´®£ºËùÓгõʼ»¯½Å±¾¶¼Ö´ÐУ»·ñÔò°´type·ÖÖ§Ö´ÐÐ + IF @type = 'SANKU_ACCIDENT_RECORD' OR @trimType = '' + BEGIN + --ʹÊʼþÊý¾Ý³õʼ»¯ + INSERT INTO SANKU_ACCIDENT_RECORD(ACCIDENT_ID,PROJECT_CODE,PROJECT_NAME,ACCIDENT_NAME,ACCIDENT_TIME,ACCIDENT_LEVEL,ACCIDENT_TYPE,ACCIDENT_LOCATION,ACCIDENT_DESCRIPTION,DEATH_COUNT,SERIOUS_INJURY_COUNT,MINOR_INJURY_COUNT + ,DIRECT_ECONOMIC_LOSS,INDIRECT_ECONOMIC_LOSS,CONTRACTING_RESPONSIBILITY,SUBCONTRACTOR_ID,SUBCONTRACTOR_CODE,SUBCONTRACTOR_NAME,POSITION_NAME,RESPONSIBILITY_TYPE,RESPONSIBILITY_DESC,PERSONNEL_ID_NUMBER,PERSONNEL_NAME,SUBMITTER_ID_NUMBER,SUBMITTER_NAME,UPDATE_TIME,CREATE_TIME) + SELECT tba.AccidentHandleId,pms.pro_code,pms.pro_name,tba.AccidentHandleName,tba.AccidentDate,tba.AccidentLevel,tba.AccidentType,tba.AccidentLocation,tba.AccidentDef,tba.DeathPersonNum,tba.InjuriesPersonNum,tba.MinorInjuriesPersonNum + ,tba.MoneyLoss,tba.IndirectMoneyLoss,tba.ContractingResponsibility + ,bu.MasterAdOrgCode,bu.CollCropCode,CASE WHEN bu.MasterAdOrgCode IS NULL OR LTRIM(RTRIM(bu.MasterAdOrgCode)) = '' THEN bu.UnitName ELSE bu.MasterAdOrgName END AS UnitName + ,tba.PositionName,tba.ResponsibilityType,tba.ResponsibilityDesc,su.IdentityCard,tba.ResponsibleManName,suc.IdentityCard,suc.UserName,tba.CompileDate,tba.CompileDate + FROM Accident_AccidentHandle AS tba WITH(NOLOCK) + LEFT JOIN Base_Unit AS bu WITH(NOLOCK) ON bu.UnitId = tba.UnitId --AND LEN(bu.CollCropCode)=18 + LEFT JOIN Sys_User AS su WITH(NOLOCK) ON su.UserId = tba.ResponsibleMan + LEFT JOIN Sys_User AS suc WITH(NOLOCK) ON suc.UserId = tba.CompileMan + LEFT JOIN Base_Project AS bp WITH(NOLOCK) ON bp.ProjectId = tba.ProjectId + LEFT JOIN ads_pms_pro_info_build AS pms WITH(NOLOCK) ON pms.pro_id = bp.MasterSysId + WHERE bp.MasterSysId IS NOT NULL AND pms.pro_code IS NOT NULL AND tba.AccidentDate>='2026-01-01' + AND (bu.MasterAdOrgCode IS NOT NULL OR LEN(bu.CollCropCode)=18) AND LEN(suc.IdentityCard)=18 AND LEN(su.IdentityCard)=18 + AND tba.AccidentHandleId NOT IN (SELECT ACCIDENT_ID FROM SANKU_ACCIDENT_RECORD WITH(NOLOCK)); + END + + IF @type = 'SANKU_VIOLATION' OR @trimType = '' + BEGIN + --Î¥ÕÂ×÷ÒµÊý¾Ý³õʼ»¯ + INSERT INTO SANKU_VIOLATION(RECORD_ID,PROJECT_CODE,PROJECT_NAME,SUBCONTRACTOR_ID,SUBCONTRACTOR_CODE,SUBCONTRACTOR_NAME,PERSONNEL_ID_NUMBER,PERSONNEL_NAME,VIOLATION_DATE,VIOLATION_LEVEL,VIOLATION_TYPE,VIOLATION_CONTENT,PENALTY_RESULT,RECTIFICATION_STATUS,SUBMITTER_ID_NUMBER,SUBMITTER_NAME,UPDATE_TIME,CREATE_TIME) + SELECT tba.ViolationPersonId,pms.pro_code,pms.pro_name,bu.MasterAdOrgCode,bu.CollCropCode + ,CASE WHEN bu.MasterAdOrgCode IS NULL OR LTRIM(RTRIM(bu.MasterAdOrgCode)) = '' THEN bu.UnitName ELSE bu.MasterAdOrgName END AS UnitName + ,spp.IdentityCard,spp.PersonName,tba.ViolationDate,tba.ViolationLevel + ,CASE tba.ViolationName WHEN '1' THEN vpn.ConstText+'-'+vpty1.ConstText WHEN '2' THEN vpn.ConstText+'-'+vpty2.ConstText ELSE '' END AS ViolationType + ,tba.ViolationDef,vphs.ConstText,tba.RectificationStatus,suc.IdentityCard,suc.UserName,tba.CompileDate,tba.CompileDate + FROM Check_ViolationPerson AS tba WITH(NOLOCK) + LEFT JOIN Base_Unit AS bu WITH(NOLOCK) ON bu.UnitId = tba.UnitId --AND LEN(bu.CollCropCode)=18 + LEFT JOIN Sys_Const AS vpn WITH(NOLOCK) ON vpn.ConstValue = tba.ViolationName AND vpn.GroupId='ViolationName' + LEFT JOIN Sys_Const AS vpty1 WITH(NOLOCK) ON vpty1.ConstValue = tba.ViolationType AND tba.ViolationName='1' AND vpty1.GroupId='ViolationType' + LEFT JOIN Sys_Const AS vpty2 WITH(NOLOCK) ON vpty2.ConstValue = tba.ViolationType AND tba.ViolationName='2' AND vpty2.GroupId='ViolationTypeOther' + LEFT JOIN Sys_Const AS vphs WITH(NOLOCK) ON vphs.ConstValue = tba.HandleStep AND vphs.GroupId='ViolationPersonHandleStep' + LEFT JOIN SitePerson_Person AS spp WITH(NOLOCK) ON spp.PersonId = tba.PersonId AND LEN(spp.IdentityCard)=18 + LEFT JOIN Sys_User AS suc WITH(NOLOCK) ON suc.UserId = tba.CompileMan + LEFT JOIN Base_Project AS bp WITH(NOLOCK) ON bp.ProjectId = tba.ProjectId + LEFT JOIN ads_pms_pro_info_build AS pms WITH(NOLOCK) ON pms.pro_id = bp.MasterSysId + WHERE bp.MasterSysId IS NOT NULL AND pms.pro_code IS NOT NULL AND tba.ViolationDate>='2026-01-01' + AND (bu.MasterAdOrgCode IS NOT NULL OR LEN(bu.CollCropCode)=18) AND LEN(suc.IdentityCard)=18 AND LEN(spp.IdentityCard)=18 + AND tba.ViolationPersonId NOT IN (SELECT RECORD_ID FROM SANKU_VIOLATION WITH(NOLOCK)); + END + + IF @type = 'SANKU_SAFETY_REWARD' OR @trimType = '' + BEGIN + --°²È«½±³ÍÊý¾Ý³õʼ»¯ + INSERT INTO SANKU_SAFETY_REWARD(RECORD_ID,PROJECT_CODE,PROJECT_NAME,PERSONNEL_ID_NUMBER,PERSONNEL_NAME,REWARD_DATE,REWARD_UNIT_ID,REWARD_UNIT_CODE,REWARD_UNIT_NAME,REWARD_TYPE,REWARD_CONTENT,REWARD_AMOUNT,REWARD_LEVEL,SUBMITTER_ID_NUMBER,SUBMITTER_NAME) + SELECT tba.RewardAndPunishID,pms.pro_code,pms.pro_name,spp.IdentityCard,spp.PersonName,tba.Date + ,bu.MasterAdOrgCode,bu.CollCropCode,CASE WHEN bu.MasterAdOrgCode IS NULL OR LTRIM(RTRIM(bu.MasterAdOrgCode)) = '' THEN bu.UnitName ELSE bu.MasterAdOrgName END AS UnitName + ,(CASE tba.Type WHEN 1 THEN '½±Àø' WHEN 2 THEN '´¦·£' ELSE '´¦·£' END) AS TYPE,tba.Description + ,(CASE WHEN tba.Type = 1 THEN ABS(tba.Money) WHEN tba.Type = 2 THEN -ABS(tba.Money) ELSE tba.Money END) AS Money + ,(CASE tba.Type + WHEN 1 THEN (SELECT ConstText FROM Sys_Const WHERE GroupId='RewardType' AND ConstValue=tba.RewardAndPunishType) + WHEN 2 THEN (SELECT ConstText FROM Sys_Const WHERE GroupId='PunishType' AND ConstValue=tba.RewardAndPunishType) END) AS TYPE + ,suc.IdentityCard,suc.UserName + FROM Check_RewardAndPunish AS tba WITH(NOLOCK) + LEFT JOIN SitePerson_Person AS spp WITH(NOLOCK) ON spp.PersonId = tba.RewardAndPunishMan --AND LEN(spp.IdentityCard)=18 + LEFT JOIN Base_Unit AS bu WITH(NOLOCK) ON bu.UnitId = tba.ResponseUnit --AND LEN(bu.CollCropCode)=18 + LEFT JOIN Sys_User AS suc WITH(NOLOCK) ON suc.UserId = tba.CreateMan + LEFT JOIN Base_Project AS bp WITH(NOLOCK) ON bp.ProjectId = tba.ProjectId + LEFT JOIN ads_pms_pro_info_build AS pms WITH(NOLOCK) ON pms.pro_id = bp.MasterSysId + WHERE bp.MasterSysId IS NOT NULL AND pms.pro_code IS NOT NULL AND tba.Date>='2026-01-01' AND tba.Type IN (1,2) + AND (bu.MasterAdOrgCode IS NOT NULL OR LEN(bu.CollCropCode)=18) AND LEN(spp.IdentityCard)=18 AND LEN(suc.IdentityCard)=18 + AND tba.RewardAndPunishID NOT IN (SELECT RECORD_ID FROM SANKU_SAFETY_REWARD WITH(NOLOCK)); + END + + IF @type = 'SANKU_SAFETY_REWARD' OR @trimType = '' + BEGIN + --ÐÐÕþ´¦·£Êý¾Ý³õʼ»¯ + INSERT INTO SANKU_ADMIN_PENALTY(RECORD_ID,PROJECT_CODE,PROJECT_NAME,SUBCONTRACTOR_ID,SUBCONTRACTOR_CODE,SUBCONTRACTOR_NAME,PENALTY_DATE,PENALTY_TYPE,PENALTY_CONTENT,PENALTY_AMOUNT,PENALTY_AUTHORITY,PENALTY_STATUS,SUBMITTER_ID_NUMBER,SUBMITTER_NAME,UPDATE_TIME,CREATE_TIME) + SELECT tba.PenaltyId,pms.pro_code,pms.pro_name + ,bu.MasterAdOrgCode,bu.CollCropCode,CASE WHEN bu.MasterAdOrgCode IS NULL OR LTRIM(RTRIM(bu.MasterAdOrgCode)) = '' THEN bu.UnitName ELSE bu.MasterAdOrgName END AS UnitName + ,tba.PenaltyDate,tba.PenaltyType,tba.PenaltyContent,tba.PenaltyAmount,tba.PenaltyAuthority,tba.PenaltyStatus + ,suc.IdentityCard,suc.UserName,tba.PenaltyDate,tba.PenaltyDate + FROM Check_AdminPenalty AS tba WITH(NOLOCK) + LEFT JOIN Base_Unit AS bu WITH(NOLOCK) ON bu.UnitId = tba.UnitId --AND LEN(bu.CollCropCode)=18 + LEFT JOIN Sys_User AS suc WITH(NOLOCK) ON suc.UserId = tba.CompileMan + LEFT JOIN Base_Project AS bp WITH(NOLOCK) ON bp.ProjectId = tba.ProjectId + LEFT JOIN ads_pms_pro_info_build AS pms WITH(NOLOCK) ON pms.pro_id = bp.MasterSysId + WHERE bp.MasterSysId IS NOT NULL AND pms.pro_code IS NOT NULL AND tba.PenaltyDate>='2026-01-01' + AND (bu.MasterAdOrgCode IS NOT NULL OR LEN(bu.CollCropCode)=18) AND LEN(suc.IdentityCard)=18 + AND tba.PenaltyId NOT IN (SELECT RECORD_ID FROM SANKU_ADMIN_PENALTY WITH(NOLOCK)); + END + + IF @type = 'SANKU_HAZARD' OR @trimType = '' + BEGIN + --Òþ»¼¼Ç¼Êý¾Ý³õʼ»¯ + INSERT INTO SANKU_HAZARD(RECORD_ID,PROJECT_CODE,PROJECT_NAME,SUBCONTRACTOR_ID,SUBCONTRACTOR_CODE,SUBCONTRACTOR_NAME,RESPONSIBLE_PERSONNEL_ID_NUMBER,RESPONSIBLE_PERSONNEL_NAME,RECTIFIER_PERSONNEL_ID_NUMBER,RECTIFIER_PERSONNEL_NAME + ,DISCOVERY_DATE,HAZARD_TYPE,HAZARD_LEVEL,HAZARD_CONTENT,RECTIFICATION_STATUS,ECTIFICATION_COMPLETIONDATE,RECTIFICATION_DEADLINE_ID,SUBMITTER_ID_NUMBER,SUBMITTER_NAME,UPDATE_TIME,CREATE_TIME) + SELECT tba.RectifyNoticesItemId,pms.pro_code,pms.pro_name + ,bu.MasterAdOrgCode,bu.CollCropCode,CASE WHEN bu.MasterAdOrgCode IS NULL OR LTRIM(RTRIM(bu.MasterAdOrgCode)) = '' THEN bu.UnitName ELSE bu.MasterAdOrgName END AS UnitName + ,suzg.IdentityCard,suzg.UserName,suzg.IdentityCard,suzg.UserName,tbb.CheckedDate,rectify.RectifyName + ,(CASE tbb.HiddenHazardType WHEN 1 THEN 'Ò»°ãÒþ»¼' WHEN 2 THEN '½Ï´óÒþ»¼' WHEN 3 THEN 'ÖØ´óÒþ»¼' ELSE 'Ò»°ãÒþ»¼' END) AS TYPE,tba.WrongContent + ,(CASE WHEN tbb.States = 2 THEN 'δÕû¸Ä' WHEN tbb.States = 3 THEN 'Õû¸ÄÖÐ' WHEN States = 4 THEN 'ÒÑÕû¸Ä' WHEN States = 5 THEN 'ÒÑÑéÊÕ' ELSE 'δÕû¸Ä' END) AS StatesName + ,tbb.CompleteDate,tba.LimitTime,suc.IdentityCard,suc.UserName,tbb.CheckedDate,tbb.CheckedDate + FROM Check_RectifyNoticesItem AS tba WITH(NOLOCK) + LEFT JOIN Check_RectifyNotices AS tbb WITH(NOLOCK) ON tbb.RectifyNoticesId = tba.RectifyNoticesId + --LEFT JOIN Check_RectifyNoticesFlowOperate AS tbc WITH(NOLOCK) ON tbc.RectifyNoticesId = tba.RectifyNoticesId + LEFT JOIN Base_Unit AS bu WITH(NOLOCK) ON bu.UnitId = tbb.UnitId --AND LEN(bu.CollCropCode)=18 + LEFT JOIN Sys_User AS suzg WITH(NOLOCK) ON suzg.UserId = tbb.DutyPersonId + LEFT JOIN Sys_User AS suc WITH(NOLOCK) ON suc.UserId = tbb.CompleteManId + LEFT JOIN Base_Project AS bp WITH(NOLOCK) ON bp.ProjectId = tbb.ProjectId + LEFT JOIN ads_pms_pro_info_build AS pms WITH(NOLOCK) ON pms.pro_id = bp.MasterSysId + LEFT JOIN Technique_Rectify AS rectify WITH(NOLOCK) ON tba.RectifyId = rectify.RectifyId + WHERE bp.MasterSysId IS NOT NULL AND pms.pro_code IS NOT NULL AND tbb.CheckedDate>='2026-01-01' AND tbb.States > 1 + AND (bu.MasterAdOrgCode IS NOT NULL OR LEN(bu.CollCropCode)=18) AND LEN(suc.IdentityCard)=18 AND LEN(suzg.IdentityCard)=18 AND rectify.RectifyName IS NOT NULL + AND tba.RectifyNoticesItemId NOT IN (SELECT RECORD_ID FROM SANKU_HAZARD WITH(NOLOCK)); + END + + IF @type = 'SANKU_TRAINING' OR @trimType = '' + BEGIN + --½ÌÓýÅàѵÊý¾Ý³õʼ»¯ + INSERT INTO SANKU_TRAINING(RECORD_ID,PROJECT_CODE,PROJECT_NAME,SUBCONTRACTOR_ID,SUBCONTRACTOR_CODE,SUBCONTRACTOR_NAME,PERSONNEL_ID_NUMBER,PERSONNEL_NAME,TRAINING_DATE,TRAINING_NAME,TRAINING_TYPE,TRAINING_DURATION,TRAINING_ORGANIZER,TRAINING_CONTENT,TRAINING_RESULT,SUBMITTER_ID_NUMBER,SUBMITTER_NAME,UPDATE_TIME,CREATE_TIME) + SELECT tba.TrainDetailId,pms.pro_code,pms.pro_name + ,spu.MasterAdOrgCode,spu.CollCropCode,CASE WHEN spu.MasterAdOrgCode IS NULL OR LTRIM(RTRIM(spu.MasterAdOrgCode)) = '' THEN spu.UnitName ELSE spu.MasterAdOrgName END AS UnitName + ,spp.IdentityCard,spp.PersonName,tbb.TrainStartDate + ,(CASE WHEN ISNULL(tbb.TrainTitle,'')='' THEN bty.TrainTypeName ELSE tbb.TrainTitle END) AS TrainName + ,bty.TrainTypeName,tbb.TeachHour,bu.UnitName + ,(CASE WHEN ISNULL(tbb.TrainContent,'')='' THEN bty.TrainTypeName ELSE tbb.TrainContent END) AS TrainContent + ,(CASE WHEN tba.CheckResult = 1 THEN 'ͨ¹ý' WHEN tba.CheckResult = 0 THEN 'δͨ¹ý' ELSE 'ȱ¿¼' END) AS CheckResult + ,suc.IdentityCard,suc.UserName,tbb.TrainStartDate,tbb.TrainStartDate + FROM EduTrain_TrainRecordDetail AS tba WITH(NOLOCK) + LEFT JOIN EduTrain_TrainRecord AS tbb WITH(NOLOCK) ON tbb.TrainingId = tba.TrainingId + LEFT JOIN Base_Unit AS bu WITH(NOLOCK) ON bu.UnitId = tbb.UnitIds --AND LEN(bu.CollCropCode)=18 + LEFT JOIN SitePerson_Person AS spp WITH(NOLOCK) ON spp.PersonId = tba.PersonId + LEFT JOIN Base_Unit AS spu WITH(NOLOCK) ON spu.UnitId = spp.UnitId --AND LEN(spu.CollCropCode)=18 + LEFT JOIN Base_TrainType AS bty WITH(NOLOCK) ON bty.TrainTypeId = tbb.TrainTypeId + LEFT JOIN Sys_User AS suc WITH(NOLOCK) ON suc.UserId = tbb.CompileMan + LEFT JOIN Base_Project AS bp WITH(NOLOCK) ON bp.ProjectId = tbb.ProjectId + LEFT JOIN ads_pms_pro_info_build AS pms WITH(NOLOCK) ON pms.pro_id = bp.MasterSysId + WHERE tbb.TrainStartDate>='2026-01-01' AND LEN(suc.IdentityCard)=18 AND LEN(spp.IdentityCard)=18 + AND (spu.MasterAdOrgCode IS NOT NULL OR LEN(spu.CollCropCode)=18) AND bp.MasterSysId IS NOT NULL AND pms.pro_code IS NOT NULL + AND tba.TrainDetailId NOT IN (SELECT RECORD_ID FROM SANKU_TRAINING WITH(NOLOCK)); + END + + IF @type = 'SANKU_EXAMINATION' OR @trimType = '' + BEGIN + --¿¼ÊÔ¿¼ºËÊý¾Ý³õʼ»¯ + INSERT INTO SANKU_EXAMINATION(RECORD_ID,PROJECT_CODE,PROJECT_NAME,SUBCONTRACTOR_ID,SUBCONTRACTOR_CODE,SUBCONTRACTOR_NAME,PERSONNEL_ID_NUMBER,PERSONNEL_NAME,EXAM_DATE,EXAM_NAME,EXAM_TYPE,EXAM_SCORE,EXAM_RESULT,EXAM_ORGANIZER,SUBMITTER_ID_NUMBER,SUBMITTER_NAME,UPDATE_TIME,CREATE_TIME) + SELECT tba.TestRecordId,pms.pro_code,pms.pro_name + ,bu.MasterAdOrgCode,bu.CollCropCode,CASE WHEN bu.MasterAdOrgCode IS NULL OR LTRIM(RTRIM(bu.MasterAdOrgCode)) = '' THEN bu.UnitName ELSE bu.MasterAdOrgName END AS UnitName + ,spp.IdentityCard,spp.PersonName,tbb.TestEndTime,tbb.PlanName,'ÀíÂÛ¿¼ÊÔ',tba.TestScores + ,(CASE WHEN tba.TestScores = 0 THEN 'ȱ¿¼' WHEN tba.TestScores >=80 THEN 'ͨ¹ý' WHEN tba.TestScores < 80 THEN 'δͨ¹ý' ELSE 'ȱ¿¼' END) AS CheckResult,tbb.UnitNames + ,suc.IdentityCard,suc.UserName,tbb.TestEndTime,tbb.TestEndTime + FROM Training_TestRecord AS tba WITH(NOLOCK) + LEFT JOIN Training_TestPlan AS tbb WITH(NOLOCK) ON tbb.TestPlanId = tba.TestPlanId + LEFT JOIN SitePerson_Person AS spp WITH(NOLOCK) ON spp.PersonId = tba.TestManId + LEFT JOIN Base_Unit AS bu WITH(NOLOCK) ON bu.UnitId = spp.UnitId --AND LEN(bu.CollCropCode)=18 + LEFT JOIN Sys_User AS suc WITH(NOLOCK) ON suc.UserId = tbb.PlanManId + LEFT JOIN Base_Project AS bp WITH(NOLOCK) ON bp.ProjectId = tbb.ProjectId + LEFT JOIN ads_pms_pro_info_build AS pms WITH(NOLOCK) ON pms.pro_id = bp.MasterSysId + WHERE tbb.TestEndTime>='2026-01-01' AND LEN(suc.IdentityCard)=18 AND LEN(spp.IdentityCard)=18 + AND (bu.MasterAdOrgCode IS NOT NULL OR LEN(bu.CollCropCode)=18) AND bp.MasterSysId IS NOT NULL AND pms.pro_code IS NOT NULL + AND tba.TestRecordId NOT IN (SELECT RECORD_ID FROM SANKU_EXAMINATION WITH(NOLOCK)); + END + + IF @type = 'SANKU_DANGEROUS_ENGINEERING' OR @trimType = '' + BEGIN + --Σ´ó¹¤³ÌÊý¾Ý³õʼ»¯ + INSERT INTO SANKU_DANGEROUS_ENGINEERING(RECORD_ID,PROJECT_CODE,PROJECT_NAME,SUBCONTRACTOR_ID,SUBCONTRACTOR_CODE,SUBCONTRACTOR_NAME,ENGINEERING_DATE,ENGINEERING_NAME,ENGINEERING_TYPE,ENGINEERING_LEVEL,ENGINEERING_STATE,ENGINEERING_ADDRESS,ENGINEERING_DESC,STANDBY_PERSONNEL_ID_NUMBER,STANDBY_PERSONNEL_NAME,SUBMITTER_ID_NUMBER,SUBMITTER_NAME,UPDATE_TIME,CREATE_TIME) + SELECT tba.HazardId,pms.pro_code,pms.pro_name,bu.MasterAdOrgCode,bu.CollCropCode + ,CASE WHEN bu.MasterAdOrgCode IS NULL OR LTRIM(RTRIM(bu.MasterAdOrgCode)) = '' THEN bu.UnitName ELSE bu.MasterAdOrgName END AS UnitName + ,ISNULL(tba.ExpectedTime,GETDATE()) AS ExpectedTime,tba.HazardName,sc.ConstText + ,(CASE tba.IsSuperLargerHazard WHEN 1 THEN '³¬¹æÄ£Î£´ó' WHEN 0 THEN 'ÆÕͨΣ´ó' ELSE 'ÆÕͨΣ´ó' END) AS Level + ,(CASE tba.States WHEN 1 THEN 'Ê©¹¤×¼±¸' WHEN 2 THEN 'ÕýÔÚÊ©¹¤' WHEN 3 THEN 'ÑéÊÕÍê³É' ELSE 'ÕýÔÚÊ©¹¤' END) AS State + ,tba.Address,tba.Descriptions,spp.IdentityCard,spp.PersonName,suc.IdentityCard,suc.UserName,tba.RecordTime,tba.RecordTime + FROM Solution_LargerHazard AS tba WITH(NOLOCK) + LEFT JOIN Base_Unit AS bu WITH(NOLOCK) ON bu.UnitId = tba.UnitId --AND LEN(bu.CollCropCode)=18 + LEFT JOIN SitePerson_Person AS spp WITH(NOLOCK) ON spp.PersonId = tba.StandbyPersonnelId + LEFT JOIN Sys_Const AS sc WITH(NOLOCK) ON sc.GroupId='LargerHazardType' AND sc.ConstValue= tba.HazardType + LEFT JOIN Sys_User AS suc WITH(NOLOCK) ON suc.UserId = tba.RecardMan + LEFT JOIN Base_Project AS bp WITH(NOLOCK) ON bp.ProjectId = tba.ProjectId + LEFT JOIN ads_pms_pro_info_build AS pms WITH(NOLOCK) ON pms.pro_id = bp.MasterSysId + WHERE tba.RecordTime>='2026-01-01' AND LEN(suc.IdentityCard)=18 AND LEN(spp.IdentityCard)=18 + AND (bu.MasterAdOrgCode IS NOT NULL OR LEN(bu.CollCropCode)=18) AND bp.MasterSysId IS NOT NULL AND pms.pro_code IS NOT NULL + AND tba.HazardId NOT IN (SELECT RECORD_ID FROM SANKU_DANGEROUS_ENGINEERING WITH(NOLOCK)); + END + + IF @type = 'SANKU_GRID_PATROL' OR @trimType = '' + BEGIN + --Íø¸ñ»¯Ñ²²é¼Ç¼Êý¾Ý³õʼ»¯ + WITH temp_data AS ( + SELECT + tba.HazardRegisterId,pms.pro_code,pms.pro_name,bu.MasterAdOrgCode,bu.CollCropCode + ,CASE WHEN bu.MasterAdOrgCode IS NULL OR LTRIM(RTRIM(bu.MasterAdOrgCode)) = '' THEN bu.UnitName ELSE bu.MasterAdOrgName END AS UnitName + ,suzg.IdentityCard AS pNumber,suzg.UserName AS pUser,ISNULL(wbsu.UnitWorkName,'') AS ItemName,DATEADD(DAY,-1,tba.CheckTime) AS ReceiveDate,tba.CheckTime,'ÒÑÍê³É' AS StatusStr,suzg.IdentityCard,suzg.UserName,tba.CheckTime AS UpdateTime,tba.CheckTime AS CreateTime, + ROW_NUMBER() OVER ( + PARTITION BY tba.CheckManId, CAST(tba.CheckTime AS DATE) + ORDER BY tba.CheckTime ASC + ) AS rn + FROM HSSE_Hazard_HazardRegister AS tba WITH(NOLOCK) + LEFT JOIN Base_Project AS bp WITH(NOLOCK) ON bp.ProjectId = tba.ProjectId + LEFT JOIN ads_pms_pro_info_build AS pms WITH(NOLOCK) ON pms.pro_id = bp.MasterSysId + LEFT JOIN WBS_UnitWork AS wbsu WITH(NOLOCK) ON wbsu.UnitWorkId = tba.Place + LEFT JOIN Sys_User AS suzg WITH(NOLOCK) ON suzg.UserId = tba.CheckManId + LEFT JOIN Base_Unit AS bu WITH(NOLOCK) ON bu.UnitId = suzg.UnitId --AND LEN(bu.CollCropCode)=18 + WHERE bp.MasterSysId IS NOT NULL AND pms.pro_code IS NOT NULL AND tba.CheckTime>='2026-01-01' + AND (bu.MasterAdOrgCode IS NOT NULL OR LEN(bu.CollCropCode)=18) AND LEN(suzg.IdentityCard)=18 + ) + --Íø¸ñ»¯Ñ²²é¼Ç¼Êý¾Ý³õʼ»¯ + INSERT INTO SANKU_GRID_PATROL(RECORD_ID,PROJECT_CODE,PROJECT_NAME,SUBCONTRACTOR_ID,SUBCONTRACTOR_CODE,SUBCONTRACTOR_NAME,PERSONNEL_ID_NUMBER,PERSONNEL_NAME,PATROL_WORKITEMS,PATROL_RECEIVEDATE,PATROL_TIME,PATROL_STATUS,SUBMITTER_ID_NUMBER,SUBMITTER_NAME,UPDATE_TIME,CREATE_TIME) + SELECT HazardRegisterId,pro_code,pro_name,MasterAdOrgCode,CollCropCode,UnitName,pNumber,pUser,'Ѳ¼ìµ¥Î»¹¤³Ì£º'+ItemName,DATEADD(DAY,-1,CheckTime),CheckTime,StatusStr,IdentityCard,UserName,UpdateTime,CreateTime + FROM temp_data + WHERE rn = 1 AND HazardRegisterId NOT IN (SELECT RECORD_ID FROM SANKU_GRID_PATROL WITH(NOLOCK)); + END + + END +END +GO + + diff --git a/SGGL/BLL/SanKu/SanKuDataSummaryReportService.cs b/SGGL/BLL/SanKu/SanKuDataSummaryReportService.cs index a1de3503..e26d14f6 100644 --- a/SGGL/BLL/SanKu/SanKuDataSummaryReportService.cs +++ b/SGGL/BLL/SanKu/SanKuDataSummaryReportService.cs @@ -243,7 +243,8 @@ namespace BLL PERSONNEL_ID_NUMBER = spp.IdentityCard, PERSONNEL_NAME = spp.PersonName, VIOLATION_DATE = (DateTime)tba.ViolationDate, - VIOLATION_TYPE = tba.ViolationLevel, + VIOLATION_LEVEL = tba.ViolationLevel, + VIOLATION_TYPE = ViolatioType(tba.ViolationName, tba.ViolationType), VIOLATION_CONTENT = tba.ViolationDef, PENALTY_RESULT = tba.RectificationStatus, RECTIFICATION_STATUS = ViolatioResult(tba.HandleStep), @@ -295,6 +296,7 @@ namespace BLL exist.PERSONNEL_ID_NUMBER = model.PERSONNEL_ID_NUMBER; exist.PERSONNEL_NAME = model.PERSONNEL_NAME; exist.VIOLATION_DATE = model.VIOLATION_DATE; + exist.VIOLATION_LEVEL = model.VIOLATION_LEVEL; exist.VIOLATION_TYPE = model.VIOLATION_TYPE; exist.VIOLATION_CONTENT = model.VIOLATION_CONTENT; exist.PENALTY_RESULT = model.PENALTY_RESULT; @@ -319,6 +321,7 @@ namespace BLL newModel.PERSONNEL_ID_NUMBER = model.PERSONNEL_ID_NUMBER; newModel.PERSONNEL_NAME = model.PERSONNEL_NAME; newModel.VIOLATION_DATE = model.VIOLATION_DATE; + newModel.VIOLATION_LEVEL = model.VIOLATION_LEVEL; newModel.VIOLATION_TYPE = model.VIOLATION_TYPE; newModel.VIOLATION_CONTENT = model.VIOLATION_CONTENT; newModel.PENALTY_RESULT = model.PENALTY_RESULT; @@ -338,6 +341,29 @@ namespace BLL } } + /// + /// è¿�章作业类型 + /// + /// + public static string ViolatioType(string name, string type) + { + string result = string.Empty; + var constObj = new Sys_Const(); + if (name == "1") + { + constObj = BLL.ConstValue.GetConstByConstValueAndGroupId(type, BLL.ConstValue.Group_ViolationType); + } + else if (name == "2") + { + constObj = BLL.ConstValue.GetConstByConstValueAndGroupId(type, BLL.ConstValue.Group_ViolationTypeOther); + } + if (constObj != null) + { + result = constObj.ConstText; + } + return result; + } + /// /// è¿�章作业处ç�†ç»“æžœ /// @@ -706,6 +732,7 @@ namespace BLL HAZARD_LEVEL = HazardLevel(tbb.HiddenHazardType), HAZARD_CONTENT = tba.WrongContent, RECTIFICATION_STATUS = HazardState(tbb.States), + ECTIFICATION_COMPLETIONDATE = tbb.CompleteDate, RECTIFICATION_DEADLINE_ID = tba.LimitTime == null ? DateTime.Now.AddDays(7) : (DateTime)tba.LimitTime, SUBMITTER_ID_NUMBER = suc.IdentityCard, SUBMITTER_NAME = suc.UserName, @@ -759,6 +786,7 @@ namespace BLL exist.HAZARD_LEVEL = model.HAZARD_LEVEL; exist.HAZARD_CONTENT = model.HAZARD_CONTENT; exist.RECTIFICATION_STATUS = model.RECTIFICATION_STATUS; + exist.ECTIFICATION_COMPLETIONDATE = model.ECTIFICATION_COMPLETIONDATE; exist.RECTIFICATION_DEADLINE_ID = model.RECTIFICATION_DEADLINE_ID; exist.SUBMITTER_ID_NUMBER = model.SUBMITTER_ID_NUMBER; exist.SUBMITTER_NAME = model.SUBMITTER_NAME; @@ -787,6 +815,7 @@ namespace BLL newModel.HAZARD_LEVEL = model.HAZARD_LEVEL; newModel.HAZARD_CONTENT = model.HAZARD_CONTENT; newModel.RECTIFICATION_STATUS = model.RECTIFICATION_STATUS; + newModel.ECTIFICATION_COMPLETIONDATE = model.ECTIFICATION_COMPLETIONDATE; newModel.RECTIFICATION_DEADLINE_ID = model.RECTIFICATION_DEADLINE_ID; newModel.SUBMITTER_ID_NUMBER = model.SUBMITTER_ID_NUMBER; newModel.SUBMITTER_NAME = model.SUBMITTER_NAME; @@ -1459,6 +1488,8 @@ namespace BLL ENGINEERING_DATE = tba.ExpectedTime == null ? DateTime.Now : (DateTime)tba.ExpectedTime, ENGINEERING_NAME = tba.HazardName, ENGINEERING_TYPE = LargerHazardType(tba.HazardType), + ENGINEERING_LEVEL = tba.IsSuperLargerHazard != null && tba.IsSuperLargerHazard == true ? "超规模å�±å¤§" : "普通å�±å¤§", + ENGINEERING_STATE = LargerHazardState(tba.States), ENGINEERING_ADDRESS = tba.Address, ENGINEERING_DESC = tba.Descriptions, STANDBY_PERSONNEL_ID_NUMBER = spp.IdentityCard, @@ -1512,6 +1543,8 @@ namespace BLL exist.ENGINEERING_DATE = model.ENGINEERING_DATE; exist.ENGINEERING_NAME = model.ENGINEERING_NAME; exist.ENGINEERING_TYPE = model.ENGINEERING_TYPE; + exist.ENGINEERING_LEVEL = model.ENGINEERING_LEVEL; + exist.ENGINEERING_STATE = model.ENGINEERING_STATE; exist.ENGINEERING_ADDRESS = model.ENGINEERING_ADDRESS; exist.ENGINEERING_DESC = model.ENGINEERING_DESC; exist.STANDBY_PERSONNEL_ID_NUMBER = model.STANDBY_PERSONNEL_ID_NUMBER; @@ -1538,6 +1571,8 @@ namespace BLL newModel.ENGINEERING_DATE = model.ENGINEERING_DATE; newModel.ENGINEERING_NAME = model.ENGINEERING_NAME; newModel.ENGINEERING_TYPE = model.ENGINEERING_TYPE; + newModel.ENGINEERING_LEVEL = model.ENGINEERING_LEVEL; + newModel.ENGINEERING_STATE = model.ENGINEERING_STATE; newModel.ENGINEERING_ADDRESS = model.ENGINEERING_ADDRESS; newModel.ENGINEERING_DESC = model.ENGINEERING_DESC; newModel.STANDBY_PERSONNEL_ID_NUMBER = model.STANDBY_PERSONNEL_ID_NUMBER; @@ -1558,6 +1593,34 @@ namespace BLL } } + /// + /// å�±å¤§å·¥ç¨‹çжæ€� + /// + /// + /// + public static string LargerHazardState(string value) + { + string result = string.Empty; + if (!string.IsNullOrWhiteSpace(value)) + { + switch (value) + { + case "1": + result = "施工准备"; + break; + case "2": + result = "正在施工"; + break; + case "3": + result = "验收完æˆ�"; + break; + default: + result = "正在施工"; + break; + } + } + return result; + } /// /// å�±å¤§å·¥ç¨‹ç±»åž‹ @@ -1602,6 +1665,7 @@ namespace BLL var models = from tba in db.HSSE_Hazard_HazardRegister join bp in db.Base_Project on tba.ProjectId equals bp.ProjectId join pms in db.Ads_pms_pro_info_build on bp.MasterSysId equals pms.Pro_id + join wbsu in db.WBS_UnitWork on tba.Place equals wbsu.UnitWorkId join suzg in db.Sys_User on tba.CheckManId equals suzg.UserId join bu in db.Base_Unit on suzg.UnitId equals bu.UnitId where tba.HazardRegisterId == hazardId @@ -1615,6 +1679,8 @@ namespace BLL SUBCONTRACTOR_NAME = bu.UnitName, PERSONNEL_ID_NUMBER = suzg.IdentityCard, PERSONNEL_NAME = suzg.UserName, + PATROL_WORKITEMS = "巡检å�•ä½�工程:" + wbsu.UnitWorkName, + PATROL_RECEIVEDATE = tba.CheckTime == null ? DateTime.Now.AddDays(-1) : ((DateTime)tba.CheckTime).AddDays(-1), PATROL_TIME = tba.CheckTime == null ? DateTime.Now : (DateTime)tba.CheckTime, PATROL_STATUS = "已完æˆ�", SUBMITTER_ID_NUMBER = suzg.IdentityCard, @@ -1666,11 +1732,13 @@ namespace BLL newModel.RECORD_ID = model.RECORD_ID; newModel.PROJECT_CODE = model.PROJECT_CODE; newModel.PROJECT_NAME = model.PROJECT_NAME; - exist.SUBCONTRACTOR_ID = model.SUBCONTRACTOR_ID; + newModel.SUBCONTRACTOR_ID = model.SUBCONTRACTOR_ID; newModel.SUBCONTRACTOR_CODE = model.SUBCONTRACTOR_CODE; newModel.SUBCONTRACTOR_NAME = model.SUBCONTRACTOR_NAME; newModel.PERSONNEL_ID_NUMBER = model.PERSONNEL_ID_NUMBER; newModel.PERSONNEL_NAME = model.PERSONNEL_NAME; + newModel.PATROL_WORKITEMS = model.PATROL_WORKITEMS; + newModel.PATROL_RECEIVEDATE = model.PATROL_RECEIVEDATE; newModel.PATROL_TIME = model.PATROL_TIME; newModel.PATROL_STATUS = model.PATROL_STATUS; //newModel.SOURCE_SYSTEM_ID = model.SOURCE_SYSTEM_ID; diff --git a/SGGL/FineUIPro.Web/SanKu/DangerousEngineering.aspx b/SGGL/FineUIPro.Web/SanKu/DangerousEngineering.aspx index 1b82463b..35ae4619 100644 --- a/SGGL/FineUIPro.Web/SanKu/DangerousEngineering.aspx +++ b/SGGL/FineUIPro.Web/SanKu/DangerousEngineering.aspx @@ -80,6 +80,12 @@ + + + + diff --git a/SGGL/FineUIPro.Web/SanKu/DangerousEngineering.aspx.cs b/SGGL/FineUIPro.Web/SanKu/DangerousEngineering.aspx.cs index a93b5519..301bc3b8 100644 --- a/SGGL/FineUIPro.Web/SanKu/DangerousEngineering.aspx.cs +++ b/SGGL/FineUIPro.Web/SanKu/DangerousEngineering.aspx.cs @@ -38,7 +38,7 @@ namespace FineUIPro.Web.SanKu /// private void BindGrid() { - string strSql = @"SELECT tba.RECORD_ID,tba.DANGEROUS_ID,tba.PROJECT_CODE,tba.PROJECT_NAME,tba.SUBCONTRACTOR_ID,tba.SUBCONTRACTOR_NAME,tba.ENGINEERING_DATE,tba.ENGINEERING_NAME,tba.ENGINEERING_TYPE,tba.ENGINEERING_ADDRESS,tba.STANDBY_PERSONNEL_NAME,tba.ReportDate + string strSql = @"SELECT tba.RECORD_ID,tba.DANGEROUS_ID,tba.PROJECT_CODE,tba.PROJECT_NAME,tba.SUBCONTRACTOR_ID,tba.SUBCONTRACTOR_NAME,tba.ENGINEERING_DATE,tba.ENGINEERING_NAME,tba.ENGINEERING_TYPE,tba.ENGINEERING_LEVEL,tba.ENGINEERING_STATE,tba.ENGINEERING_ADDRESS,tba.STANDBY_PERSONNEL_NAME,tba.ReportDate FROM SANKU_DANGEROUS_ENGINEERING AS tba WITH(NOLOCK) WHERE 1=1 "; List listStr = new List(); diff --git a/SGGL/FineUIPro.Web/SanKu/GridPatrol.aspx b/SGGL/FineUIPro.Web/SanKu/GridPatrol.aspx index 00c92b6a..60aeea68 100644 --- a/SGGL/FineUIPro.Web/SanKu/GridPatrol.aspx +++ b/SGGL/FineUIPro.Web/SanKu/GridPatrol.aspx @@ -76,7 +76,7 @@ - - + + + + private void BindGrid() { - string strSql = @"SELECT tba.RECORD_ID,tba.PATROL_ID,tba.PROJECT_CODE,tba.PROJECT_NAME,tba.SUBCONTRACTOR_ID,tba.SUBCONTRACTOR_NAME,tba.PERSONNEL_ID_NUMBER,tba.PERSONNEL_NAME,tba.PATROL_TIME,tba.PATROL_STATUS,tba.ReportDate + string strSql = @"SELECT tba.RECORD_ID,tba.PATROL_ID,tba.PROJECT_CODE,tba.PROJECT_NAME,tba.SUBCONTRACTOR_ID,tba.SUBCONTRACTOR_NAME,tba.PERSONNEL_ID_NUMBER,tba.PERSONNEL_NAME,tba.PATROL_WORKITEMS,tba.PATROL_RECEIVEDATE,tba.PATROL_TIME,tba.PATROL_STATUS,tba.ReportDate FROM SANKU_GRID_PATROL AS tba WITH(NOLOCK) WHERE 1=1 "; List listStr = new List(); diff --git a/SGGL/FineUIPro.Web/SanKu/Hazard.aspx b/SGGL/FineUIPro.Web/SanKu/Hazard.aspx index dd7bf04b..0318a6c3 100644 --- a/SGGL/FineUIPro.Web/SanKu/Hazard.aspx +++ b/SGGL/FineUIPro.Web/SanKu/Hazard.aspx @@ -120,6 +120,9 @@ + + diff --git a/SGGL/FineUIPro.Web/SanKu/Hazard.aspx.cs b/SGGL/FineUIPro.Web/SanKu/Hazard.aspx.cs index 723c4735..95b91f00 100644 --- a/SGGL/FineUIPro.Web/SanKu/Hazard.aspx.cs +++ b/SGGL/FineUIPro.Web/SanKu/Hazard.aspx.cs @@ -39,7 +39,7 @@ namespace FineUIPro.Web.SanKu /// private void BindGrid() { - string strSql = @"SELECT tba.HAZARD_ID,tba.RECORD_ID,tba.PROJECT_CODE,tba.PROJECT_NAME,tba.SUBCONTRACTOR_ID,tba.SUBCONTRACTOR_NAME,tba.RESPONSIBLE_PERSONNEL_NAME,tba.RECTIFIER_PERSONNEL_NAME,tba.DISCOVERY_DATE,tba.HAZARD_TYPE,tba.HAZARD_CONTENT,tba.HAZARD_LEVEL,tba.RECTIFICATION_STATUS,tba.RECTIFICATION_DEADLINE_ID,tba.ReportDate + string strSql = @"SELECT tba.HAZARD_ID,tba.RECORD_ID,tba.PROJECT_CODE,tba.PROJECT_NAME,tba.SUBCONTRACTOR_ID,tba.SUBCONTRACTOR_NAME,tba.RESPONSIBLE_PERSONNEL_NAME,tba.RECTIFIER_PERSONNEL_NAME,tba.DISCOVERY_DATE,tba.HAZARD_TYPE,tba.HAZARD_CONTENT,tba.HAZARD_LEVEL,tba.RECTIFICATION_STATUS,tba.ECTIFICATION_COMPLETIONDATE,tba.RECTIFICATION_DEADLINE_ID,tba.ReportDate FROM SANKU_HAZARD AS tba WITH(NOLOCK) WHERE 1=1 "; List listStr = new List(); diff --git a/SGGL/FineUIPro.Web/SanKu/VioLation.aspx b/SGGL/FineUIPro.Web/SanKu/VioLation.aspx index 2f515d00..52f0a86d 100644 --- a/SGGL/FineUIPro.Web/SanKu/VioLation.aspx +++ b/SGGL/FineUIPro.Web/SanKu/VioLation.aspx @@ -99,7 +99,10 @@ - + + private void BindGrid() { - string strSql = @"SELECT tba.VIOLATION_ID,tba.RECORD_ID,tba.PROJECT_CODE,tba.PROJECT_NAME,tba.SUBCONTRACTOR_ID,tba.SUBCONTRACTOR_NAME,tba.PERSONNEL_NAME,tba.VIOLATION_DATE,tba.VIOLATION_TYPE,tba.VIOLATION_CONTENT,tba.PENALTY_RESULT,tba.RECTIFICATION_STATUS,tba.ReportDate + string strSql = @"SELECT tba.VIOLATION_ID,tba.RECORD_ID,tba.PROJECT_CODE,tba.PROJECT_NAME,tba.SUBCONTRACTOR_ID,tba.SUBCONTRACTOR_NAME,tba.PERSONNEL_NAME,tba.VIOLATION_DATE,tba.VIOLATION_LEVEL,tba.VIOLATION_TYPE,tba.VIOLATION_CONTENT,tba.PENALTY_RESULT,tba.RECTIFICATION_STATUS,tba.ReportDate FROM SANKU_VIOLATION AS tba WITH(NOLOCK) WHERE 1=1 "; List listStr = new List(); @@ -64,7 +64,7 @@ namespace FineUIPro.Web.SanKu string rectificationStatus = this.drpRectificationStatus.SelectedValue.Trim(); if (!string.IsNullOrWhiteSpace(violationLevel)) { - strSql += " AND tba.VIOLATION_TYPE = @ViolationLevel"; + strSql += " AND tba.VIOLATION_LEVEL = @ViolationLevel"; listStr.Add(new SqlParameter("@ViolationLevel", violationLevel)); } if (!string.IsNullOrWhiteSpace(rectificationStatus)) diff --git a/SGGL/Model/Model.cs b/SGGL/Model/Model.cs index bc670ad6..1c151b9a 100644 --- a/SGGL/Model/Model.cs +++ b/SGGL/Model/Model.cs @@ -232888,7 +232888,7 @@ namespace Model } } - [global::System.Data.Linq.Mapping.ColumnAttribute(Storage="_PlanName", DbType="NVarChar(50)")] + [global::System.Data.Linq.Mapping.ColumnAttribute(Storage="_PlanName", DbType="NVarChar(200)")] public string PlanName { get @@ -232968,7 +232968,7 @@ namespace Model } } - [global::System.Data.Linq.Mapping.ColumnAttribute(Storage="_Remarks", DbType="NVarChar(50)")] + [global::System.Data.Linq.Mapping.ColumnAttribute(Storage="_Remarks", DbType="NVarChar(200)")] public string Remarks { get @@ -354240,6 +354240,10 @@ namespace Model private System.Nullable _ReportDate; + private string _ENGINEERING_LEVEL; + + private string _ENGINEERING_STATE; + #region å�¯æ‰©å±•性方法定义 partial void OnLoaded(); partial void OnValidate(System.Data.Linq.ChangeAction action); @@ -354292,6 +354296,10 @@ namespace Model partial void OnUnitNameChanged(); partial void OnReportDateChanging(System.Nullable value); partial void OnReportDateChanged(); + partial void OnENGINEERING_LEVELChanging(string value); + partial void OnENGINEERING_LEVELChanged(); + partial void OnENGINEERING_STATEChanging(string value); + partial void OnENGINEERING_STATEChanged(); #endregion public SANKU_DANGEROUS_ENGINEERING() @@ -354779,6 +354787,46 @@ namespace Model } } + [global::System.Data.Linq.Mapping.ColumnAttribute(Storage="_ENGINEERING_LEVEL", DbType="VarChar(20)")] + public string ENGINEERING_LEVEL + { + get + { + return this._ENGINEERING_LEVEL; + } + set + { + if ((this._ENGINEERING_LEVEL != value)) + { + this.OnENGINEERING_LEVELChanging(value); + this.SendPropertyChanging(); + this._ENGINEERING_LEVEL = value; + this.SendPropertyChanged("ENGINEERING_LEVEL"); + this.OnENGINEERING_LEVELChanged(); + } + } + } + + [global::System.Data.Linq.Mapping.ColumnAttribute(Storage="_ENGINEERING_STATE", DbType="VarChar(20)")] + public string ENGINEERING_STATE + { + get + { + return this._ENGINEERING_STATE; + } + set + { + if ((this._ENGINEERING_STATE != value)) + { + this.OnENGINEERING_STATEChanging(value); + this.SendPropertyChanging(); + this._ENGINEERING_STATE = value; + this.SendPropertyChanged("ENGINEERING_STATE"); + this.OnENGINEERING_STATEChanged(); + } + } + } + public event PropertyChangingEventHandler PropertyChanging; public event PropertyChangedEventHandler PropertyChanged; @@ -355486,6 +355534,10 @@ namespace Model private System.Nullable _ReportDate; + private string _PATROL_WORKITEMS; + + private System.Nullable _PATROL_RECEIVEDATE; + #region å�¯æ‰©å±•性方法定义 partial void OnLoaded(); partial void OnValidate(System.Data.Linq.ChangeAction action); @@ -355532,6 +355584,10 @@ namespace Model partial void OnUnitNameChanged(); partial void OnReportDateChanging(System.Nullable value); partial void OnReportDateChanged(); + partial void OnPATROL_WORKITEMSChanging(string value); + partial void OnPATROL_WORKITEMSChanged(); + partial void OnPATROL_RECEIVEDATEChanging(System.Nullable value); + partial void OnPATROL_RECEIVEDATEChanged(); #endregion public SANKU_GRID_PATROL() @@ -355959,6 +356015,46 @@ namespace Model } } + [global::System.Data.Linq.Mapping.ColumnAttribute(Storage="_PATROL_WORKITEMS", DbType="VarChar(200)")] + public string PATROL_WORKITEMS + { + get + { + return this._PATROL_WORKITEMS; + } + set + { + if ((this._PATROL_WORKITEMS != value)) + { + this.OnPATROL_WORKITEMSChanging(value); + this.SendPropertyChanging(); + this._PATROL_WORKITEMS = value; + this.SendPropertyChanged("PATROL_WORKITEMS"); + this.OnPATROL_WORKITEMSChanged(); + } + } + } + + [global::System.Data.Linq.Mapping.ColumnAttribute(Storage="_PATROL_RECEIVEDATE", DbType="DateTime")] + public System.Nullable PATROL_RECEIVEDATE + { + get + { + return this._PATROL_RECEIVEDATE; + } + set + { + if ((this._PATROL_RECEIVEDATE != value)) + { + this.OnPATROL_RECEIVEDATEChanging(value); + this.SendPropertyChanging(); + this._PATROL_RECEIVEDATE = value; + this.SendPropertyChanged("PATROL_RECEIVEDATE"); + this.OnPATROL_RECEIVEDATEChanged(); + } + } + } + public event PropertyChangingEventHandler PropertyChanging; public event PropertyChangedEventHandler PropertyChanged; @@ -356040,6 +356136,8 @@ namespace Model private System.Nullable _ReportDate; + private System.Nullable _ECTIFICATION_COMPLETIONDATE; + #region å�¯æ‰©å±•性方法定义 partial void OnLoaded(); partial void OnValidate(System.Data.Linq.ChangeAction action); @@ -356098,6 +356196,8 @@ namespace Model partial void OnUnitNameChanged(); partial void OnReportDateChanging(System.Nullable value); partial void OnReportDateChanged(); + partial void OnECTIFICATION_COMPLETIONDATEChanging(System.Nullable value); + partial void OnECTIFICATION_COMPLETIONDATEChanged(); #endregion public SANKU_HAZARD() @@ -356645,6 +356745,26 @@ namespace Model } } + [global::System.Data.Linq.Mapping.ColumnAttribute(Storage="_ECTIFICATION_COMPLETIONDATE", DbType="DateTime")] + public System.Nullable ECTIFICATION_COMPLETIONDATE + { + get + { + return this._ECTIFICATION_COMPLETIONDATE; + } + set + { + if ((this._ECTIFICATION_COMPLETIONDATE != value)) + { + this.OnECTIFICATION_COMPLETIONDATEChanging(value); + this.SendPropertyChanging(); + this._ECTIFICATION_COMPLETIONDATE = value; + this.SendPropertyChanged("ECTIFICATION_COMPLETIONDATE"); + this.OnECTIFICATION_COMPLETIONDATEChanged(); + } + } + } + public event PropertyChangingEventHandler PropertyChanging; public event PropertyChangedEventHandler PropertyChanged; @@ -358202,6 +358322,8 @@ namespace Model private System.Nullable _ReportDate; + private string _VIOLATION_LEVEL; + #region å�¯æ‰©å±•性方法定义 partial void OnLoaded(); partial void OnValidate(System.Data.Linq.ChangeAction action); @@ -358254,6 +358376,8 @@ namespace Model partial void OnUnitNameChanged(); partial void OnReportDateChanging(System.Nullable value); partial void OnReportDateChanged(); + partial void OnVIOLATION_LEVELChanging(string value); + partial void OnVIOLATION_LEVELChanged(); #endregion public SANKU_VIOLATION() @@ -358741,6 +358865,26 @@ namespace Model } } + [global::System.Data.Linq.Mapping.ColumnAttribute(Storage="_VIOLATION_LEVEL", DbType="VarChar(20)")] + public string VIOLATION_LEVEL + { + get + { + return this._VIOLATION_LEVEL; + } + set + { + if ((this._VIOLATION_LEVEL != value)) + { + this.OnVIOLATION_LEVELChanging(value); + this.SendPropertyChanging(); + this._VIOLATION_LEVEL = value; + this.SendPropertyChanged("VIOLATION_LEVEL"); + this.OnVIOLATION_LEVELChanged(); + } + } + } + public event PropertyChangingEventHandler PropertyChanging; public event PropertyChangedEventHandler PropertyChanged; diff --git a/SGGL/Model/SanKu/SankuDangerousEngineering.cs b/SGGL/Model/SanKu/SankuDangerousEngineering.cs index 8eaf8c7d..4912a551 100644 --- a/SGGL/Model/SanKu/SankuDangerousEngineering.cs +++ b/SGGL/Model/SanKu/SankuDangerousEngineering.cs @@ -48,6 +48,8 @@ namespace Model public DateTime ENGINEERING_DATE { get; set; } public string ENGINEERING_NAME { get; set; } public string ENGINEERING_TYPE { get; set; } + public string ENGINEERING_LEVEL { get; set; } + public string ENGINEERING_STATE { get; set; } public string ENGINEERING_ADDRESS { get; set; } public string ENGINEERING_DESC { get; set; } public string STANDBY_PERSONNEL_ID_NUMBER { get; set; } diff --git a/SGGL/Model/SanKu/SankuGridPatrol.cs b/SGGL/Model/SanKu/SankuGridPatrol.cs index ac448f32..527078e5 100644 --- a/SGGL/Model/SanKu/SankuGridPatrol.cs +++ b/SGGL/Model/SanKu/SankuGridPatrol.cs @@ -47,6 +47,8 @@ namespace Model public string SUBCONTRACTOR_NAME { get; set; } public string PERSONNEL_ID_NUMBER { get; set; } public string PERSONNEL_NAME { get; set; } + public string PATROL_WORKITEMS { get; set; } + public DateTime PATROL_RECEIVEDATE { get; set; } public DateTime PATROL_TIME { get; set; } public string PATROL_STATUS { get; set; } //public string SOURCE_SYSTEM_ID { get; set; } diff --git a/SGGL/Model/SanKu/SankuHazard.cs b/SGGL/Model/SanKu/SankuHazard.cs index 8df08cc0..8b26b558 100644 --- a/SGGL/Model/SanKu/SankuHazard.cs +++ b/SGGL/Model/SanKu/SankuHazard.cs @@ -54,6 +54,7 @@ namespace Model public string HAZARD_LEVEL { get; set; } public string HAZARD_CONTENT { get; set; } public string RECTIFICATION_STATUS { get; set; } + public DateTime? ECTIFICATION_COMPLETIONDATE { get; set; } public DateTime RECTIFICATION_DEADLINE_ID { get; set; } //public string SOURCE_SYSTEM_ID { get; set; } //public string SOURCE_SYSTEM_NAME { get; set; } diff --git a/SGGL/Model/SanKu/SankuViolation.cs b/SGGL/Model/SanKu/SankuViolation.cs index 8cdde720..4d2e0c8b 100644 --- a/SGGL/Model/SanKu/SankuViolation.cs +++ b/SGGL/Model/SanKu/SankuViolation.cs @@ -48,6 +48,7 @@ namespace Model public string PERSONNEL_ID_NUMBER { get; set; } public string PERSONNEL_NAME { get; set; } public DateTime VIOLATION_DATE { get; set; } + public string VIOLATION_LEVEL { get; set; } public string VIOLATION_TYPE { get; set; } public string VIOLATION_CONTENT { get; set; } public string PENALTY_RESULT { get; set; }