CNCEC_SUBQHSE_WUHUAN/DataBase/版本日志/SUBQHSE_V2026-02-13-xiaj.sql

130 lines
6.8 KiB
Transact-SQL

--班前会补充字段
IF NOT EXISTS (SELECT 1 FROM INFORMATION_SCHEMA.COLUMNS WHERE TABLE_NAME = 'Meeting_ClassMeeting' AND COLUMN_NAME = 'Remark')
BEGIN
ALTER TABLE Meeting_ClassMeeting ADD Remark nvarchar(500);
END
GO
--项目表补充字段:总包单位、总包单位项目
IF NOT EXISTS (SELECT 1 FROM INFORMATION_SCHEMA.COLUMNS WHERE TABLE_NAME = 'Base_Project' AND COLUMN_NAME = 'SubjectUnit')
BEGIN
-- 总包单位
ALTER TABLE Base_Project ADD SubjectUnit nvarchar(50) COLLATE Chinese_PRC_CI_AS NULL;
-- 总包单位下项目id
ALTER TABLE Base_Project ADD SubjectProject nvarchar(50) COLLATE Chinese_PRC_CI_AS NULL;
END
GO
--数据来源
alter table HSSE_Hazard_HazardRegister add DataSource char(1) COLLATE Chinese_PRC_CI_AS NULL;
EXEC sp_addextendedproperty
'MS_Description', N'数据来源(1总包,0本单位)',
'SCHEMA', N'dbo',
'TABLE', N'HSSE_Hazard_HazardRegister',
'COLUMN', N'DataSource'
GO
--定制版需要根据具体的菜单名称进行修改为"安全健康检查"
update [dbo].[Sys_Menu] set MenuName = '安全健康检查' WHERE MenuName = '安全健康日常巡检' and IsUsed = '1'
--菜单安全技术-临时用电方案表
--注意:菜单父级位置根据定制单位结构放置【五环放在施工方案(Menu_HSSE)下面】
IF NOT EXISTS (SELECT * FROM Sys_Menu WHERE MenuId = '09B2A0A6-A693-4F1D-A4F5-D5DEA803D771')
BEGIN
INSERT INTO dbo.Sys_Menu (MenuId, MenuName,Url, SortIndex, SuperMenu, MenuType, IsOffice, IsEnd, IsUsed)
VALUES (N'09B2A0A6-A693-4F1D-A4F5-D5DEA803D771', N'临时用电方案', N'HSSE/Solution/TemporaryElectricity.aspx', 40, '5FF7BBD8-3E0A-4C90-8976-AFF5CE7E17A5', 'Menu_HSSE', 0,1, 1);
END
--安全技术-临时用电方案表
IF NOT EXISTS (SELECT * FROM sys.objects WHERE object_id = OBJECT_ID(N'Solution_TemporaryElectricity') AND type = N'U')
BEGIN
CREATE TABLE [dbo].[Solution_TemporaryElectricity](
[TemporaryElectricityId] [nvarchar](50) NOT NULL,
[ProjectId] [nvarchar](50) NULL,
[Code] [nvarchar](100) NULL,
[Name] [nvarchar](200) NULL,
[Content] [nvarchar](2000) NULL,
[Remark] [nvarchar](500) NULL,
[CompileMan] [nvarchar](50) NULL,
[CompileDate] [datetime] NULL,
CONSTRAINT [PK_Solution_TemporaryElectricity] PRIMARY KEY CLUSTERED
(
[TemporaryElectricityId] ASC
)WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY]
) ON [PRIMARY]
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'主键' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Solution_TemporaryElectricity', @level2type=N'COLUMN',@level2name=N'TemporaryElectricityId'
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'项目id' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Solution_TemporaryElectricity', @level2type=N'COLUMN',@level2name=N'ProjectId'
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'编号' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Solution_TemporaryElectricity', @level2type=N'COLUMN',@level2name=N'Code'
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'方案名称' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Solution_TemporaryElectricity', @level2type=N'COLUMN',@level2name=N'Name'
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'内容' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Solution_TemporaryElectricity', @level2type=N'COLUMN',@level2name=N'Content'
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'备注' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Solution_TemporaryElectricity', @level2type=N'COLUMN',@level2name=N'Remark'
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'编制人' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Solution_TemporaryElectricity', @level2type=N'COLUMN',@level2name=N'CompileMan'
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'编制日期' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Solution_TemporaryElectricity', @level2type=N'COLUMN',@level2name=N'CompileDate'
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'临时用电方案' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Solution_TemporaryElectricity'
END
GO
update Sys_Menu set MenuName='临时用电方案'
WHERE MenuId = '09B2A0A6-A693-4F1D-A4F5-D5DEA803D771'
update Sys_Menu set MenuName='临时用电方案'
WHERE MenuId = 'B04483D5-4421-4046-8B1A-E97589952150'
GO
--临时用电方案补充字段
IF NOT EXISTS (SELECT 1 FROM INFORMATION_SCHEMA.COLUMNS WHERE TABLE_NAME = 'Solution_TemporaryElectricity' AND COLUMN_NAME = 'Remark')
BEGIN
ALTER TABLE Solution_TemporaryElectricity ADD Content nvarchar(2000);
ALTER TABLE Solution_TemporaryElectricity ADD Remark nvarchar(500);
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'内容' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Solution_TemporaryElectricity', @level2type=N'COLUMN',@level2name=N'Content'
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'备注' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Solution_TemporaryElectricity', @level2type=N'COLUMN',@level2name=N'Remark'
END
GO
--安全技术-临时用电表操作按钮
IF NOT EXISTS (SELECT * FROM Sys_ButtonToMenu WHERE MenuId = '09B2A0A6-A693-4F1D-A4F5-D5DEA803D771')
BEGIN
INSERT INTO [dbo].[Sys_ButtonToMenu] ([ButtonToMenuId], [MenuId], [ButtonName], [SortIndex])
VALUES (N'A633C879-BE46-4D2B-BAC3-9A656396AD53', N'09B2A0A6-A693-4F1D-A4F5-D5DEA803D771', N'增加', 1);
INSERT INTO [dbo].[Sys_ButtonToMenu] ([ButtonToMenuId], [MenuId], [ButtonName], [SortIndex])
VALUES (N'3C001F6B-428B-4BDC-8913-FD00CAC63C64', N'09B2A0A6-A693-4F1D-A4F5-D5DEA803D771', N'修改', 2);
INSERT INTO [dbo].[Sys_ButtonToMenu] ([ButtonToMenuId], [MenuId], [ButtonName], [SortIndex])
VALUES (N'E510ABD6-50B2-4685-8DB8-E362B88E8F9E', N'09B2A0A6-A693-4F1D-A4F5-D5DEA803D771', N'删除', 3);
INSERT INTO [dbo].[Sys_ButtonToMenu] ([ButtonToMenuId], [MenuId], [ButtonName], [SortIndex])
VALUES (N'9552542D-879F-49A7-BB33-7F1B54D9658F', N'09B2A0A6-A693-4F1D-A4F5-D5DEA803D771', N'保存', 4);
END
GO
----菜单设置报错脚本补充处理
--IF NOT EXISTS (SELECT * FROM Sys_Const WHERE ID = '28BF7713-44E7-43C1-B24A-7342CDD561A7')
--BEGIN
-- INSERT INTO dbo.Sys_Const (ID, ConstValue, ConstText, SortIndex, GroupId, Remark)
-- VALUES (N'28BF7713-44E7-43C1-B24A-7342CDD561A7', N'System_Qwms', N'质量与焊接管理系统', 2, N'SystemClassification', null);
--END
--GO
--IF NOT EXISTS (SELECT * FROM Sys_Const WHERE ID = '5823ADE9-302E-4402-BA6E-80F440BF184E')
--BEGIN
-- INSERT INTO dbo.Sys_Const (ID, ConstValue, ConstText, SortIndex, GroupId, Remark)
-- VALUES (N'5823ADE9-302E-4402-BA6E-80F440BF184E', N'System_Hsse', N'安全与职业健康管理系统', 1, N'SystemClassification', null);
--END
--GO