CNCEC_SUBQHSE_WUHUAN/DataBase/版本日志/已更新脚本/SGGLDB_V2021-02-08-001.sql

89 lines
3.7 KiB
Transact-SQL

CREATE TABLE [dbo].[ProcessControl_InspectionManagementDetail](
[InspectionDetailId] [nvarchar](50) NOT NULL,
[InspectionId] [nvarchar](50) NULL,
[UnitWorkId] [nvarchar](50) NULL,
[Branch] [nvarchar](50) NULL,
[ControlPointType] [nvarchar](50) NULL,
[CreateDate] [datetime] NULL,
CONSTRAINT [PK_ProcessControl_InspectionManagementDetail] PRIMARY KEY CLUSTERED
(
[InspectionDetailId] ASC
)WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY]
) ON [PRIMARY]
GO
ALTER TABLE [dbo].[ProcessControl_InspectionManagementDetail] WITH CHECK ADD CONSTRAINT [FK_ProcessControl_InspectionManagementDetail_ProcessControl_InspectionManagement] FOREIGN KEY([InspectionId])
REFERENCES [dbo].[ProcessControl_InspectionManagement] ([InspectionId])
GO
ALTER TABLE [dbo].[ProcessControl_InspectionManagementDetail] CHECK CONSTRAINT [FK_ProcessControl_InspectionManagementDetail_ProcessControl_InspectionManagement]
GO
ALTER TABLE [dbo].[ProcessControl_InspectionManagementDetail] WITH CHECK ADD CONSTRAINT [FK_ProcessControl_InspectionManagementDetail_WBS_UnitWork] FOREIGN KEY([UnitWorkId])
REFERENCES [dbo].[WBS_UnitWork] ([UnitWorkId])
GO
ALTER TABLE [dbo].[ProcessControl_InspectionManagementDetail] CHECK CONSTRAINT [FK_ProcessControl_InspectionManagementDetail_WBS_UnitWork]
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'Ö÷¼ü' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail', @level2type=N'COLUMN',@level2name=N'InspectionDetailId'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'Íâ¼ü' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail', @level2type=N'COLUMN',@level2name=N'InspectionId'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'µ¥Î»¹¤³ÌId' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail', @level2type=N'COLUMN',@level2name=N'UnitWorkId'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'·Ö²¿Id' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail', @level2type=N'COLUMN',@level2name=N'Branch'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'¿ØÖƵãId' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail', @level2type=N'COLUMN',@level2name=N'ControlPointType'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'´´½¨Ê±¼ä' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail', @level2type=N'COLUMN',@level2name=N'CreateDate'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'¹²¼ì֪ͨµ¥Ã÷ϸ±í' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail'
GO
CREATE VIEW [dbo].[View_CQMS_InspectionManagementDetail]
AS
/********¹²¼ì֪ͨµ¥********/
SELECT Detail.InspectionDetailId,
Detail.InspectionId,
Detail.UnitWorkId,
Detail.Branch,
Detail.ControlPointType,
Detail.CreateDate,
IM.ProjectId,
IM.UnitId,
IM.CNProfessionalId,
IM.InspectionCode,
IM.AcceptanceSite,
IM.IsOnceQualified,
IM.InspectionDate,
IM.AttachUrl,
IM.CheckDate,
IM.CheckMan,
IM.UnqualifiedReason,
IM.NoticeCode,
IM.AcceptanceCheckMan,
IM.ParentDivisionProjectId,
IM.CompileMan,
IM.CompileDate,
IM.FileType,
IM.AttachUrl2
FROM dbo.ProcessControl_InspectionManagementDetail AS Detail
LEFT JOIN ProcessControl_InspectionManagement AS IM ON IM.InspectionId=Detail.InspectionId
GO