CREATE TABLE [dbo].[ProcessControl_InspectionManagementDetail](
 | 
						|
	[InspectionDetailId] [nvarchar](50) NOT NULL,
 | 
						|
	[InspectionId] [nvarchar](50) NULL,
 | 
						|
	[UnitWorkId] [nvarchar](50) NULL,
 | 
						|
	[Branch] [nvarchar](50) NULL,
 | 
						|
	[ControlPointType] [nvarchar](50) NULL,
 | 
						|
	[CreateDate] [datetime] NULL,
 | 
						|
 CONSTRAINT [PK_ProcessControl_InspectionManagementDetail] PRIMARY KEY CLUSTERED 
 | 
						|
(
 | 
						|
	[InspectionDetailId] ASC
 | 
						|
)WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY]
 | 
						|
) ON [PRIMARY]
 | 
						|
 | 
						|
GO
 | 
						|
 | 
						|
ALTER TABLE [dbo].[ProcessControl_InspectionManagementDetail]  WITH CHECK ADD  CONSTRAINT [FK_ProcessControl_InspectionManagementDetail_ProcessControl_InspectionManagement] FOREIGN KEY([InspectionId])
 | 
						|
REFERENCES [dbo].[ProcessControl_InspectionManagement] ([InspectionId])
 | 
						|
GO
 | 
						|
 | 
						|
ALTER TABLE [dbo].[ProcessControl_InspectionManagementDetail] CHECK CONSTRAINT [FK_ProcessControl_InspectionManagementDetail_ProcessControl_InspectionManagement]
 | 
						|
GO
 | 
						|
 | 
						|
ALTER TABLE [dbo].[ProcessControl_InspectionManagementDetail]  WITH CHECK ADD  CONSTRAINT [FK_ProcessControl_InspectionManagementDetail_WBS_UnitWork] FOREIGN KEY([UnitWorkId])
 | 
						|
REFERENCES [dbo].[WBS_UnitWork] ([UnitWorkId])
 | 
						|
GO
 | 
						|
 | 
						|
ALTER TABLE [dbo].[ProcessControl_InspectionManagementDetail] CHECK CONSTRAINT [FK_ProcessControl_InspectionManagementDetail_WBS_UnitWork]
 | 
						|
GO
 | 
						|
 | 
						|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'Ö÷¼ü' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail', @level2type=N'COLUMN',@level2name=N'InspectionDetailId'
 | 
						|
GO
 | 
						|
 | 
						|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'Íâ¼ü' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail', @level2type=N'COLUMN',@level2name=N'InspectionId'
 | 
						|
GO
 | 
						|
 | 
						|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'µ¥Î»¹¤³ÌId' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail', @level2type=N'COLUMN',@level2name=N'UnitWorkId'
 | 
						|
GO
 | 
						|
 | 
						|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'·Ö²¿Id' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail', @level2type=N'COLUMN',@level2name=N'Branch'
 | 
						|
GO
 | 
						|
 | 
						|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'¿ØÖƵãId' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail', @level2type=N'COLUMN',@level2name=N'ControlPointType'
 | 
						|
GO
 | 
						|
 | 
						|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'´´½¨Ê±¼ä' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail', @level2type=N'COLUMN',@level2name=N'CreateDate'
 | 
						|
GO
 | 
						|
 | 
						|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'¹²¼ì֪ͨµ¥Ã÷ϸ±í' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ProcessControl_InspectionManagementDetail'
 | 
						|
GO
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
CREATE VIEW [dbo].[View_CQMS_InspectionManagementDetail]
 | 
						|
AS
 | 
						|
/********¹²¼ì֪ͨµ¥********/
 | 
						|
SELECT Detail.InspectionDetailId, 
 | 
						|
Detail.InspectionId, 
 | 
						|
Detail.UnitWorkId, 
 | 
						|
Detail.Branch, 
 | 
						|
Detail.ControlPointType,
 | 
						|
Detail.CreateDate, 
 | 
						|
IM.ProjectId,
 | 
						|
IM.UnitId,
 | 
						|
IM.CNProfessionalId,
 | 
						|
IM.InspectionCode,
 | 
						|
IM.AcceptanceSite,
 | 
						|
IM.IsOnceQualified, 
 | 
						|
IM.InspectionDate, 
 | 
						|
IM.AttachUrl,
 | 
						|
IM.CheckDate,   
 | 
						|
IM.CheckMan,   
 | 
						|
IM.UnqualifiedReason, 
 | 
						|
IM.NoticeCode, 
 | 
						|
IM.AcceptanceCheckMan, 
 | 
						|
IM.ParentDivisionProjectId, 
 | 
						|
IM.CompileMan,  
 | 
						|
IM.CompileDate,   
 | 
						|
IM.FileType, 
 | 
						|
IM.AttachUrl2
 | 
						|
FROM dbo.ProcessControl_InspectionManagementDetail AS Detail
 | 
						|
LEFT JOIN ProcessControl_InspectionManagement AS IM ON IM.InspectionId=Detail.InspectionId
 | 
						|
 | 
						|
 | 
						|
GO
 | 
						|
 | 
						|
 |