Files
SGGL_SHJ/SGGL/FineUIPro.Web/PHTGL/BiddingManagement/ActionPlanReviewEdit.aspx.cs
T

249 lines
11 KiB
C#
Raw Normal View History

2022-09-05 16:36:31 +08:00
using BLL;
using System;
using System.Collections.Generic;
using System.Data;
using System.Data.SqlClient;
2024-03-11 23:25:08 +08:00
using Model;
2022-09-05 16:36:31 +08:00
namespace FineUIPro.Web.PHTGL.BiddingManagement
{
public partial class ActionPlanReviewEdit : PageBase
{
#region 定义属性
/// <summary>
/// 审批人字典
/// </summary>
public Dictionary<int, string> Dic_ApproveMan
{
get
{
return (Dictionary<int, string>)ViewState["Dic_ApproveMan"];
}
set
{
ViewState["Dic_ApproveMan"] = value;
}
}
public List<ApproveManModel> ApproveManModels
{
get
{
return (List<ApproveManModel>)Session["ApproveManModels"];
}
set
{
Session["ApproveManModels"] = value;
}
}
public string ActionPlanReviewId
{
get
{
return (string)ViewState["ActionPlanReviewId"];
}
set
{
ViewState["ActionPlanReviewId"] = value;
}
}
#endregion
protected void Page_Load(object sender, EventArgs e)
{
if (!IsPostBack)
{
this.btnClose.OnClientClick = ActiveWindow.GetHideReference();
ActionPlanReviewId = Request.Params["ActionPlanReviewId"];
#region 绑定下拉列表
2023-03-01 13:57:09 +08:00
BLL.DepartService.InitDepartDropDownList(DropDepart, true);
2022-09-05 16:36:31 +08:00
/// 绑定施工管理部正副主任
BLL.Person_PersonsService.InitUserProjectIdUnitIdRoleIdDropDownList(Approval_Construction, null, CurrUser.UnitId, Const.ConstructionMinister + "," + Const.ConstructionViceMinister, false);
BLL.Person_PersonsService.InitUserProjectIdUnitIdRoleIdDropDownList(DropConstructionManager, null, Const.UnitId_SEDIN, null, true);
BLL.Person_PersonsService.InitUserProjectIdUnitIdRoleIdDropDownList(DropPreliminaryMan, null, Const.UnitId_SEDIN, null, true);
BLL.Person_PersonsService.InitUserProjectIdUnitIdRoleIdDropDownList(DropProjectManager, null, Const.UnitId_SEDIN, null, true);
BLL.Person_PersonsService.InitUserProjectIdUnitIdRoleIdDropDownList(DropDeputyGeneralManager, null, this.CurrUser.UnitId, Const.DeputyGeneralManager, false);
if (PHTGL_ActionPlanReviewService.IsSpecialProject(this.CurrUser.LoginProjectId))
{
2023-03-16 18:20:05 +08:00
BLL.Person_PersonsService.InitUserProjectIdUnitIdRoleIdDropDownList(Approval_Construction, null, CurrUser.UnitId, Const.ConstructionLabor, false);
2022-09-05 16:36:31 +08:00
DropConstructionManager.Label = "现场执行经理";
Approval_Construction.Label = "劳务管理组";
DropProjectManager.Label = "运营管理部";
}
#endregion
BindGrid();
BindForm();
var newmodel = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
if (newmodel != null)
{
if (newmodel.State > Const.ContractCreat_Complete)
{
this.btnSave.Hidden = true;
this.btnSubmit.Hidden = true;
}
}
}
}
private void BindForm()
{
var act = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
drpProjectId.Value = Convert.ToString(act.ActionPlanID);
Approval_Construction.SelectedValue = Convert.ToString(act.Approval_Construction);
DropConstructionManager.SelectedValue = Convert.ToString(act.ConstructionManager);
DropPreliminaryMan.SelectedValue = Convert.ToString(act.PreliminaryMan);
DropProjectManager.SelectedValue = Convert.ToString(act.ProjectManager);
DropDeputyGeneralManager.SelectedValue = Convert.ToString(act.DeputyGeneralManager);
2023-03-01 13:57:09 +08:00
DropDepart.SelectedValue = Convert.ToString(act.DepartId);
2022-09-05 16:36:31 +08:00
}
/// <summary>
/// 数据绑定
/// </summary>
private void BindGrid()
{
string strSql = @"SELECT Act.ActionPlanID
,Act.ActionPlanCode
,Pro.ProjectName as Name
,Pro.ProjectCode
,U.PersonName as CreatUser
,Act.CreateTime
,Act.ProjectID
,Act.ProjectName
,Act.Unit
,Act.ConstructionSite "
+ @" FROM PHTGL_ActionPlanFormation AS Act "
+ @" LEFT JOIN Person_Persons AS U ON U.PersonId = Act.CreatUser "
+ @" LEFT JOIN Base_Project AS Pro ON Pro.ProjectId = Act.ProjectID WHERE 1=1 and Act.State=@ContractCreat_Complete";
List<SqlParameter> listStr = new List<SqlParameter>();
listStr.Add(new SqlParameter("@ContractCreat_Complete", Const.ContractCreat_Complete));
if (!(this.CurrUser.PersonId == Const.sysglyId))
{
strSql += " and Act.ProjectID =@ProjectId";
listStr.Add(new SqlParameter("@ProjectId", this.CurrUser.LoginProjectId));
}
SqlParameter[] parameter = listStr.ToArray();
DataTable tb = SQLHelper.GetDataTableRunText(strSql, parameter);
Grid1.RecordCount = tb.Rows.Count;
var table = this.GetPagedDataTable(Grid1, tb);
Grid1.DataSource = table;
Grid1.DataBind();
}
private bool Save()
{
bool isOk = false;
if (string.IsNullOrEmpty(drpProjectId.Value))
{
ShowNotify("请选择合同", MessageBoxIcon.Warning);
return isOk;
}
2023-03-01 13:57:09 +08:00
if (DropDepart.SelectedValue == Const._Null)
{
ShowNotify("请选择部门!", MessageBoxIcon.Warning);
return false;
}
2022-09-05 16:36:31 +08:00
if (Approval_Construction.SelectedValue == Const._Null)
{
2023-03-01 13:57:09 +08:00
ShowNotify("请选择部门审批人员", MessageBoxIcon.Warning);
2022-09-05 16:36:31 +08:00
return isOk;
}
//0 是审批中 1是成功 2是失败
Model.PHTGL_ActionPlanReview newmodel = new Model.PHTGL_ActionPlanReview();
newmodel.ActionPlanReviewId = ActionPlanReviewId;
newmodel.ActionPlanID = drpProjectId.Value;
newmodel.Approval_Construction = Approval_Construction.SelectedValue;
newmodel.State = Const.ContractCreat_Complete;
newmodel.CreateUser = this.CurrUser.PersonId;
newmodel.ConstructionManager = DropConstructionManager.SelectedValue;
newmodel.PreliminaryMan = DropPreliminaryMan.SelectedValue;
newmodel.ProjectManager = DropProjectManager.SelectedValue;
newmodel.DeputyGeneralManager = DropDeputyGeneralManager.SelectedValue;
2023-03-01 13:57:09 +08:00
newmodel.DepartId = DropDepart.SelectedValue;
2022-09-05 16:36:31 +08:00
BLL.PHTGL_ActionPlanReviewService.UpdatePHTGL_ActionPlanReview(newmodel);
isOk = true;
return isOk;
}
private void CreateApprove()
{
var newmodel = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
var _Act = BLL.PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(newmodel.ActionPlanID);
Dic_ApproveMan = PHTGL_ActionPlanReviewService.Get_DicApproveman(_Act.ProjectID, newmodel.ActionPlanReviewId);
ApproveManModels = PHTGL_ActionPlanReviewService.GetApproveManModels(_Act.ProjectID, newmodel.ActionPlanReviewId);
//创建第一节点审批信息
Model.PHTGL_Approve _Approve = new Model.PHTGL_Approve();
_Approve.ApproveId = SQLHelper.GetNewID(typeof(Model.PHTGL_Approve));
_Approve.ContractId = newmodel.ActionPlanReviewId;
_Approve.ApproveMan = ApproveManModels.Find(e => e.Number == 1).userid;
_Approve.ApproveDate = "";
_Approve.State = 0;
_Approve.IsAgree = 0;
_Approve.ApproveIdea = "";
_Approve.ApproveType = ApproveManModels.Find(e => e.Number == 1).Rolename;
_Approve.IsPushOa = 0;
_Approve.ApproveForm = PHTGL_ApproveService.ActionPlanReview;
BLL.PHTGL_ApproveService.AddPHTGL_Approve(_Approve);
}
protected void btnSave_Click(object sender, EventArgs e)
{
if (Save())
{
ShowNotify("保存成功!", MessageBoxIcon.Success);
PageContext.RegisterStartupScript(ActiveWindow.GetHideRefreshReference());
}
}
protected void btnSubmit_Click(object sender, EventArgs e)
{
if (Save())
{
CreateApprove();
var model1 = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
model1.State = Const.ContractReviewing;
PHTGL_ActionPlanReviewService.UpdatePHTGL_ActionPlanReview(model1);
//model2.State= Const.ContractReviewing;
//PHTGL_ActionPlanFormationService.UpdatePHTGL_ActionPlanFormation(model2);
OAWebSevice.Pushoa();
PageContext.RegisterStartupScript(ActiveWindow.GetHideRefreshReference());
}
}
#region DropDownList下拉选择事件
/// <summary>
/// 选择项目Id获取会签评审人员信息
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void DropDownBox1_TextChanged(object sender, EventArgs e)
{
if (this.drpProjectId.Value != BLL.Const._Null)
{
Model.PHTGL_ActionPlanFormation table = BLL.PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(this.drpProjectId.Value);
string UnitId = ProjectService.GetProjectByProjectId(table.ProjectID).UnitId;
//施工经理
this.DropConstructionManager.SelectedValue = BLL.SitePerson_PersonService.GetPersonIdByProjectIdRoleID(table.ProjectID, BLL.Const.ConstructionManager);
//项目经理
this.DropProjectManager.SelectedValue = BLL.SitePerson_PersonService.GetPersonIdByProjectIdRoleID(table.ProjectID, BLL.Const.ProjectManager);
//分管副总经理
this.DropDeputyGeneralManager.SelectedValue = BLL.SitePerson_PersonService.GetPersonIdByProjectIdRoleID(UnitId, BLL.Const.DeputyGeneralManager);
}
}
#endregion
}
}