2022-09-05 16:36:31 +08:00
namespace FineUIPro.Web.PHTGL.BiddingManagement
{
using BLL ;
using System ;
using System.Collections.Generic ;
using System.Data ;
using System.Data.SqlClient ;
using System.Linq ;
public partial class ActionPlanReview : PageBase
{
#region 加 载
/// <summary>
/// 加载页面
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Page_Load ( object sender , EventArgs e )
{
if ( ! IsPostBack )
{
Funs . DropDownPageSize ( this . ddlPageSize ) ;
this . DropState . DataValueField = "Value" ;
DropState . DataTextField = "Text" ;
DropState . DataSource = BLL . DropListService . GetState ( ) ;
DropState . DataBind ( ) ;
Funs . FineUIPleaseSelect ( DropState ) ;
DropState . SelectedValueArray = new string [ ]
{
Const . ContractCreat_Complete . ToString ( ) ,
Const . ContractReviewing . ToString ( ) ,
Const . ContractReview_Refuse . ToString ( )
} ;
GetButtonPower ( ) ;
BindGrid ( ) ;
}
}
#endregion
#region 数 据 绑 定
/// <summary>
/// 数据绑定
/// </summary>
private void BindGrid ( )
{
string strSql = @"SELECT APR.ActionPlanReviewId
,APR.ActionPlanID
,Act.ActionPlanCode
,Pro.ProjectName
,Pro.ProjectCode
,Act.ProjectShortName as Name
,Act.EPCCode
, (CASE APR.State
WHEN @ContractCreat_Complete THEN '编制完成'
WHEN @ContractReviewing THEN '审批中'
WHEN @ContractReview_Complete THEN '审批完成'
WHEN @ContractReview_Refuse THEN '审批被拒'END) AS State
,ApproveType =stuff((select ','+ ApproveType from PHTGL_Approve app2 where app2.ContractId = APR.ActionPlanReviewId and app2 .state =0 for xml path('')), 1, 1, '')
,APR.Approval_Construction
,Act.CreateTime
,U.PersonName AS CreateUser "
+ @" FROM PHTGL_ActionPlanReview AS APR "
+ @" LEFT JOIN Person_Persons AS U ON U.PersonId = APR.CreateUser "
+ @" LEFT JOIN PHTGL_ActionPlanFormation AS Act ON Act.ActionPlanID=APR.ActionPlanID"
+ @" LEFT JOIN Base_Project AS Pro ON Pro.ProjectId = Act.ProjectID WHERE 1=1 " ;
List < SqlParameter > listStr = new List < SqlParameter > ( ) ;
listStr . Add ( new SqlParameter ( "@ContractCreat_Complete" , Const . ContractCreat_Complete ) ) ;
listStr . Add ( new SqlParameter ( "@ContractReviewing" , Const . ContractReviewing ) ) ;
listStr . Add ( new SqlParameter ( "@ContractReview_Complete" , Const . ContractReview_Complete ) ) ;
listStr . Add ( new SqlParameter ( "@ContractReview_Refuse" , Const . ContractReview_Refuse ) ) ;
if ( ! ( this . CurrUser . PersonId = = Const . sysglyId ) )
{
strSql + = " and Act.ProjectID =@ProjectId" ;
listStr . Add ( new SqlParameter ( "@ProjectId" , this . CurrUser . LoginProjectId ) ) ;
}
if ( ! string . IsNullOrEmpty ( txtActionPlanCode . Text ) )
{
strSql + = " and Act.ActionPlanCode like @ActionPlanCode " ;
listStr . Add ( new SqlParameter ( "@ActionPlanCode" , "%" + txtActionPlanCode . Text + "%" ) ) ;
}
if ( DropState . SelectedItemArray . Length > 0 )
{
strSql + = string . Format ( " and APR.State in ({0}) " , string . Join ( "," , DropState . SelectedValueArray ) ) ;
}
SqlParameter [ ] parameter = listStr . ToArray ( ) ;
DataTable tb = SQLHelper . GetDataTableRunText ( strSql , parameter ) ;
Grid1 . RecordCount = tb . Rows . Count ;
var table = this . GetPagedDataTable ( Grid1 , tb ) ;
Grid1 . DataSource = table ;
Grid1 . DataBind ( ) ;
}
#endregion
#region 分 页 排 序
/// <summary>
/// 改变索引事件
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Grid1_PageIndexChange ( object sender , GridPageEventArgs e )
{
BindGrid ( ) ;
}
/// <summary>
/// 分页下拉选择事件
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void ddlPageSize_SelectedIndexChanged ( object sender , EventArgs e )
{
Grid1 . PageSize = Convert . ToInt32 ( ddlPageSize . SelectedValue ) ;
BindGrid ( ) ;
}
/// <summary>
/// 排序
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Grid1_Sort ( object sender , FineUIPro . GridSortEventArgs e )
{
BindGrid ( ) ;
}
protected void Grid1_RowCommand ( object sender , GridCommandEventArgs e )
{
object [ ] keys = Grid1 . DataKeys [ e . RowIndex ] ;
string fileId = string . Empty ;
if ( keys = = null )
{
return ;
}
else
{
fileId = keys [ 0 ] . ToString ( ) ;
}
if ( e . CommandName = = "LooK" )
{
string id = fileId ;
var Act = BLL . PHTGL_ActionPlanReviewService . GetPHTGL_ActionPlanReviewById ( id ) ;
PageContext . RegisterStartupScript ( Window1 . GetShowReference ( String . Format ( "ActionPlanFormationEdit.aspx?ActionPlanID={0}" , Act . ActionPlanID , "编辑 - " ) ) ) ;
return ;
}
}
#endregion
#region 关 闭 弹 出 窗 体
/// <summary>
/// 关闭弹出窗体
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Window1_Close ( object sender , WindowCloseEventArgs e )
{
BindGrid ( ) ;
}
#endregion
#region 查 询 重 置
/// <summary>
/// 查询按钮
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void btnSearch_Click ( object sender , EventArgs e )
{
BindGrid ( ) ;
OAWebSevice . Pushoa ( ) ;
}
protected void btnRset_Click ( object sender , EventArgs e )
{
txtActionPlanCode . Text = "" ;
DropState . SelectedValueArray = new string [ ] {
Const . ContractCreat_Complete . ToString ( ) ,
Const . ContractReviewing . ToString ( ) ,
Const . ContractReview_Refuse . ToString ( )
} ;
BindGrid ( ) ;
}
protected void btnQueryApprove_Click ( object sender , EventArgs e )
{
this . EditData ( ) ;
}
#endregion
#region 编 辑
/// <summary>
/// 双击事件
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Grid1_RowDoubleClick ( object sender , GridRowClickEventArgs e )
{
this . EditData ( ) ;
}
/// <summary>
/// 单击事件EnableRowClickEvent="false"未启用
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Grid1_RowClick ( object sender , GridRowClickEventArgs e )
{
string id = Grid1 . SelectedRowID ;
var actReview = PHTGL_ActionPlanReviewService . GetPHTGL_ActionPlanReviewById ( id ) ;
if ( actReview . State = = Const . ContractReview_Refuse )
{
btnEditActPlan . Hidden = false ;
}
else
{
btnEditActPlan . Hidden = true ;
}
}
protected void btnEditActPlan_Click ( object sender , EventArgs e )
{
if ( Grid1 . SelectedRowIndexArray . Length = = 0 )
{
Alert . ShowInTop ( "请至少选择一条记录!" , MessageBoxIcon . Warning ) ;
return ;
}
string id = Grid1 . SelectedRowID ;
string actplanId = PHTGL_ActionPlanReviewService . GetPHTGL_ActionPlanReviewById ( id ) . ActionPlanID ;
var model = PHTGL_ActionPlanFormationService . GetPHTGL_ActionPlanFormationById ( actplanId ) ;
model . State = Const . ContractCreating ;
PHTGL_ActionPlanFormationService . UpdatePHTGL_ActionPlanFormation ( model ) ;
PageContext . RegisterStartupScript ( Window1 . GetShowReference ( String . Format ( "ActionPlanFormationEdit.aspx?ActionPlanID={0}" , actplanId , "编辑 - " ) ) ) ;
}
/// <summary>
/// 重新提交
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void btnMenuEdit_Click ( object sender , EventArgs e )
{
if ( Grid1 . SelectedRowIndexArray . Length = = 0 )
{
Alert . ShowInTop ( "请至少选择一条记录!" , MessageBoxIcon . Warning ) ;
return ;
}
string id = Grid1 . SelectedRowID ;
var actReview = PHTGL_ActionPlanReviewService . GetPHTGL_ActionPlanReviewById ( id ) ;
if ( actReview . State < Const . ContractReviewing )
{
Alert . ShowInTop ( "还未创建审批流无法重新提交!" , MessageBoxIcon . Warning ) ;
return ;
}
actReview . State = Const . ContractReviewing ;
if ( actReview . CreateUser ! = this . CurrUser . PersonId )
{
string name = Person_PersonsService . GetPersonsNameById ( actReview . CreateUser ) ;
Alert . ShowInTop ( "!此审批不是您创建,无法重新提交【创建者:" + name + "】" , MessageBoxIcon . Warning ) ;
return ;
}
BLL . PHTGL_ActionPlanReviewService . UpdatePHTGL_ActionPlanReview ( actReview ) ;
/////改变实施计划表状态
//var model = PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(actReview.ActionPlanID);
//model.State = Const.ContractReviewing;
//PHTGL_ActionPlanFormationService.UpdatePHTGL_ActionPlanFormation(model);
///删除历史审批记录
// PHTGL_ApproveService.DeletePHTGL_ApproveBycontractId(id);
var _ActFormation = BLL . PHTGL_ActionPlanFormationService . GetPHTGL_ActionPlanFormationById ( actReview . ActionPlanID ) ;
//创建第一节点审批信息
var ApproveManModels = PHTGL_ActionPlanReviewService . GetApproveManModels ( _ActFormation . ProjectID , actReview . ActionPlanReviewId ) ;
Model . PHTGL_Approve _Approve = new Model . PHTGL_Approve ( ) ;
_Approve . ApproveId = SQLHelper . GetNewID ( typeof ( Model . PHTGL_Approve ) ) ;
_Approve . ContractId = actReview . ActionPlanReviewId ;
_Approve . ApproveMan = ApproveManModels . Find ( x = > x . Number = = 1 ) . userid ;
_Approve . ApproveDate = "" ;
_Approve . State = 0 ;
_Approve . IsAgree = 0 ;
_Approve . ApproveIdea = "" ;
_Approve . ApproveType = ApproveManModels . Find ( x = > x . Number = = 1 ) . Rolename ;
_Approve . IsPushOa = 0 ;
_Approve . ApproveForm = PHTGL_ApproveService . ActionPlanReview ;
BLL . PHTGL_ApproveService . AddPHTGL_Approve ( _Approve ) ;
OAWebSevice . Pushoa ( ) ;
ShowNotify ( "重新提交成功!" , MessageBoxIcon . Success ) ;
BindGrid ( ) ;
}
/// <summary>
/// 编辑数据方法
/// </summary>
private void EditData ( )
{
if ( Grid1 . SelectedRowIndexArray . Length = = 0 )
{
Alert . ShowInTop ( "请至少选择一条记录!" , MessageBoxIcon . Warning ) ;
return ;
}
string id = Grid1 . SelectedRowID ;
PageContext . RegisterStartupScript ( Window1 . GetShowReference ( String . Format ( "ActionPlanReviewDetail.aspx?ActionPlanReviewId={0}" , id , "编辑 - " ) ) ) ;
}
#endregion
#region 添 加
protected void btnNew_Click ( object sender , EventArgs e )
{
if ( Grid1 . SelectedRowIndexArray . Length = = 0 )
{
Alert . ShowInTop ( "请至少选择一条记录!" , MessageBoxIcon . Warning ) ;
return ;
}
string id = Grid1 . SelectedRowID ;
PageContext . RegisterStartupScript ( Window1 . GetShowReference ( String . Format ( "ActionPlanReviewEdit.aspx?ActionPlanReviewId={0}" , id , "编辑 - " ) ) ) ;
}
#endregion
#region 删 除
/// <summary>
/// 右键删除事件
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void btnMenuDelete_Click ( object sender , EventArgs e )
{
if ( Grid1 . SelectedRowIndexArray . Length > 0 )
{
bool isShow = false ;
if ( Grid1 . SelectedRowIndexArray . Length = = 1 )
{
isShow = true ;
}
foreach ( int rowIndex in Grid1 . SelectedRowIndexArray )
{
string rowID = Grid1 . DataKeys [ rowIndex ] [ 0 ] . ToString ( ) ;
if ( this . judgementDelete ( rowID , isShow ) )
{
var p = BLL . PHTGL_ActionPlanReviewService . GetPHTGL_ActionPlanReviewById ( rowID ) ;
if ( p ! = null )
{
BLL . LogService . AddSys_Log ( this . CurrUser , p . CreateUser , p . ActionPlanID , BLL . Const . ActionPlanReview , BLL . Const . BtnDelete ) ;
PHTGL_ApproveService . DeletePHTGL_ApproveBycontractId ( rowID ) ;
BLL . PHTGL_ActionPlanReviewService . DeletePHTGL_ActionPlanReviewById ( rowID ) ;
}
}
}
BindGrid ( ) ;
ShowNotify ( "删除数据成功!" , MessageBoxIcon . Success ) ;
}
}
/// <summary>
/// 判断是否可以删除
/// </summary>
/// <returns></returns>
private bool judgementDelete ( string id , bool isShow )
{
string content = string . Empty ;
if ( string . IsNullOrEmpty ( content ) )
{
return true ;
}
else
{
if ( isShow )
{
Alert . ShowInTop ( content ) ;
}
return false ;
}
}
#endregion
#region 获 取 按 钮 权 限
/// <summary>
/// 获取按钮权限
/// </summary>
/// <param name="button"></param>
/// <returns></returns>
private void GetButtonPower ( )
{
if ( Request . Params [ "value" ] = = "0" )
{
return ;
}
var buttonList = CommonService . GetAllButtonList ( CurrUser . LoginProjectId , CurrUser . PersonId , Const . ActionPlanReview ) ;
if ( buttonList . Count ( ) > 0 )
{
if ( buttonList . Contains ( Const . BtnAdd ) )
{
btnNew . Hidden = false ;
}
//if (buttonList.Contains(Const.BtnDelete))
//{
// btnDelete.Hidden = false;
//}
}
}
#endregion
#region 打 印
/// <summary>
/// 打印
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void btnPrinter_Click ( object sender , EventArgs e )
{
if ( Grid1 . SelectedRowIndexArray . Length = = 0 )
{
Alert . ShowInTop ( "请至少选择一条记录!" , MessageBoxIcon . Warning ) ;
return ;
}
string Id = Grid1 . SelectedRowID ;
var Act = PHTGL_ActionPlanReviewService . GetPHTGL_ActionPlanReviewById ( Id ) ;
if ( Act = = null )
{
Alert . ShowInTop ( "还未创建审批流无法导出!" , MessageBoxIcon . Warning ) ;
return ;
}
string ActionPlanID = Act . ActionPlanID ;
2023-03-03 10:46:14 +08:00
//ActionPlanFormation actionPlanFormation = new ActionPlanFormation();
//actionPlanFormation.Print(ActionPlanID);
BLL . PHTGL_ActionPlanFormationService . PrintFile ( ActionPlanID ) ;
2022-09-05 16:36:31 +08:00
}
#endregion
}
}