2022-09-08 合同基本修改,焊接数据分析修改

This commit is contained in:
2022-09-08 20:14:51 +08:00
parent e0f256688a
commit 6881455e9d
22 changed files with 2744 additions and 259 deletions
@@ -59,16 +59,16 @@ namespace FineUIPro.Mobile.PHTGL.BiddingManagement
Session["ApproveManModels"] = value;
}
}
public string UserId
public string PersonId
{
get
{
UserId = Request.Params["UserId"];
return (string)ViewState["UserId"];
PersonId = Request.Params["PersonId"];
return (string)ViewState["PersonId"];
}
set
{
ViewState["UserId"] = value;
ViewState["PersonId"] = value;
}
}
#endregion
@@ -86,23 +86,23 @@ namespace FineUIPro.Mobile.PHTGL.BiddingManagement
ApproveManModels = PHTGL_ActionPlanReviewService.GetApproveManModels(_ActionPlanFormation.ProjectID, ActionPlanReviewId);
EndApproveType = ApproveManModels.Count;
//获取当前登录人审批信息
pHTGL_Approve = BLL.PHTGL_ApproveService.GetPHTGL_ApproveByUserId(ActionPlanReviewId, UserId);
pHTGL_Approve = BLL.PHTGL_ApproveService.GetPHTGL_ApproveByUserId(ActionPlanReviewId, PersonId);
this.txtProjectCode.Text = _ActionPlanFormation.EPCCode;
this.txtProjectName.Text = _ActionPlanFormation.ProjectShortName;
this.txtCreateUser.Text = BLL.Person_PersonsService.GetPersonsNameById(_ActionPlanFormation.CreatUser);
if (PHTGL_ApproveService.IsApproveMan(ActionPlanReviewId, UserId))
if (PHTGL_ApproveService.IsApproveMan(ActionPlanReviewId, PersonId))
{
BindGrid();
}
else if (UserId == Const.sysglyId || UserId == Const.hfnbdId)
else if (PersonId == Const.sysglyId || PersonId == Const.hfnbdId)
{
BindGrid();
}
else if (_ActionPlanFormation.CreatUser == UserId)
else if (_ActionPlanFormation.CreatUser == PersonId)
{
BindGrid();
}
@@ -125,7 +125,7 @@ namespace FineUIPro.Mobile.PHTGL.BiddingManagement
/// </summary>
private void BindGrid()
{
string strSql = @" select u.UserName as ApproveMan,
string strSql = @" select u.PersonName as ApproveMan,
App.ApproveDate,
(CASE App.IsAgree WHEN '1' THEN '不同意'
WHEN '2' THEN '同意' END) AS IsAgree,
@@ -133,7 +133,7 @@ namespace FineUIPro.Mobile.PHTGL.BiddingManagement
App.ApproveId,
App.ApproveType
from PHTGL_Approve as App"
+ @" left join Sys_User AS U ON U.UserId = App.ApproveMan WHERE 1=1 and App.IsAgree <>0 and app.ContractId= @ContractId order by convert(datetime ,App.ApproveDate) ";
+ @" left join SitePerson_Person AS U ON U.PersonId = App.ApproveMan WHERE 1=1 and App.IsAgree <>0 and app.ContractId= @ContractId order by convert(datetime ,App.ApproveDate) ";
List<SqlParameter> listStr = new List<SqlParameter>();
listStr.Add(new SqlParameter("@ContractId", ActionPlanReviewId));