namespace FineUIPro.Web.PHTGL.BiddingManagement { using BLL; using System; using System.Collections.Generic; using System.Data; using System.Data.SqlClient; using System.Linq; public partial class ActionPlanReview : PageBase { #region 加载 /// /// 加载页面 /// /// /// protected void Page_Load(object sender, EventArgs e) { if (!IsPostBack) { Funs.DropDownPageSize(this.ddlPageSize); this.DropState.DataValueField = "Value"; DropState.DataTextField = "Text"; DropState.DataSource = BLL.DropListService.GetState(); DropState.DataBind(); Funs.FineUIPleaseSelect(DropState); DropState.SelectedValueArray = new string[] { Const.ContractCreat_Complete.ToString (), Const.ContractReviewing.ToString (), Const.ContractReview_Refuse.ToString() }; GetButtonPower(); BindGrid(); } } #endregion #region 数据绑定 /// /// 数据绑定 /// private void BindGrid() { string strSql = @"SELECT APR.ActionPlanReviewId ,APR.ActionPlanID ,Act.ActionPlanCode ,Pro.ProjectName ,Pro.ProjectCode ,Act.ProjectShortName as Name ,Act.EPCCode , (CASE APR.State WHEN @ContractCreat_Complete THEN '编制完成' WHEN @ContractReviewing THEN '审批中' WHEN @ContractReview_Complete THEN '审批完成' WHEN @ContractReview_Refuse THEN '审批被拒'END) AS State ,ApproveType =stuff((select ','+ ApproveType from PHTGL_Approve app2 where app2.ContractId = APR.ActionPlanReviewId and app2 .state =0 for xml path('')), 1, 1, '') ,APR.Approval_Construction ,Act.CreateTime ,U.PersonName AS CreateUser " + @" FROM PHTGL_ActionPlanReview AS APR " + @" LEFT JOIN Person_Persons AS U ON U.PersonId = APR.CreateUser " + @" LEFT JOIN PHTGL_ActionPlanFormation AS Act ON Act.ActionPlanID=APR.ActionPlanID" + @" LEFT JOIN Base_Project AS Pro ON Pro.ProjectId = Act.ProjectID WHERE 1=1 "; List listStr = new List(); listStr.Add(new SqlParameter("@ContractCreat_Complete", Const.ContractCreat_Complete)); listStr.Add(new SqlParameter("@ContractReviewing", Const.ContractReviewing)); listStr.Add(new SqlParameter("@ContractReview_Complete", Const.ContractReview_Complete)); listStr.Add(new SqlParameter("@ContractReview_Refuse", Const.ContractReview_Refuse)); if (!(this.CurrUser.PersonId == Const.sysglyId)) { strSql += " and Act.ProjectID =@ProjectId"; listStr.Add(new SqlParameter("@ProjectId", this.CurrUser.LoginProjectId)); } if (!string.IsNullOrEmpty(txtActionPlanCode.Text)) { strSql += " and Act.ActionPlanCode like @ActionPlanCode "; listStr.Add(new SqlParameter("@ActionPlanCode", "%" + txtActionPlanCode.Text + "%")); } if (DropState.SelectedItemArray.Length > 0) { strSql += string.Format(" and APR.State in ({0}) ", string.Join(",", DropState.SelectedValueArray)); } SqlParameter[] parameter = listStr.ToArray(); DataTable tb = SQLHelper.GetDataTableRunText(strSql, parameter); Grid1.RecordCount = tb.Rows.Count; var table = this.GetPagedDataTable(Grid1, tb); Grid1.DataSource = table; Grid1.DataBind(); } #endregion #region 分页 排序 /// /// 改变索引事件 /// /// /// protected void Grid1_PageIndexChange(object sender, GridPageEventArgs e) { BindGrid(); } /// /// 分页下拉选择事件 /// /// /// protected void ddlPageSize_SelectedIndexChanged(object sender, EventArgs e) { Grid1.PageSize = Convert.ToInt32(ddlPageSize.SelectedValue); BindGrid(); } /// /// 排序 /// /// /// protected void Grid1_Sort(object sender, FineUIPro.GridSortEventArgs e) { BindGrid(); } protected void Grid1_RowCommand(object sender, GridCommandEventArgs e) { object[] keys = Grid1.DataKeys[e.RowIndex]; string fileId = string.Empty; if (keys == null) { return; } else { fileId = keys[0].ToString(); } if (e.CommandName == "LooK") { string id = fileId; var Act = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(id); PageContext.RegisterStartupScript(Window1.GetShowReference(String.Format("ActionPlanFormationEdit.aspx?ActionPlanID={0}", Act.ActionPlanID, "编辑 - "))); return; } } #endregion #region 关闭弹出窗体 /// /// 关闭弹出窗体 /// /// /// protected void Window1_Close(object sender, WindowCloseEventArgs e) { BindGrid(); } #endregion #region 查询 重置 /// /// 查询按钮 /// /// /// protected void btnSearch_Click(object sender, EventArgs e) { BindGrid(); OAWebSevice.Pushoa(); } protected void btnRset_Click(object sender, EventArgs e) { txtActionPlanCode.Text = ""; DropState.SelectedValueArray = new string[] { Const.ContractCreat_Complete.ToString (), Const.ContractReviewing.ToString (), Const.ContractReview_Refuse.ToString() }; BindGrid(); } protected void btnQueryApprove_Click(object sender, EventArgs e) { this.EditData(); } #endregion #region 编辑 /// /// 双击事件 /// /// /// protected void Grid1_RowDoubleClick(object sender, GridRowClickEventArgs e) { this.EditData(); } /// /// 单击事件EnableRowClickEvent="false"未启用 /// /// /// protected void Grid1_RowClick(object sender, GridRowClickEventArgs e) { string id = Grid1.SelectedRowID; var actReview = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(id); if (actReview.State == Const.ContractReview_Refuse) { btnEditActPlan.Hidden = false; } else { btnEditActPlan.Hidden = true; } } protected void btnEditActPlan_Click(object sender, EventArgs e) { if (Grid1.SelectedRowIndexArray.Length == 0) { Alert.ShowInTop("请至少选择一条记录!", MessageBoxIcon.Warning); return; } string id = Grid1.SelectedRowID; string actplanId = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(id).ActionPlanID; var model = PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(actplanId); model.State = Const.ContractCreating; PHTGL_ActionPlanFormationService.UpdatePHTGL_ActionPlanFormation(model); PageContext.RegisterStartupScript(Window1.GetShowReference(String.Format("ActionPlanFormationEdit.aspx?ActionPlanID={0}", actplanId, "编辑 - "))); } /// /// 重新提交 /// /// /// protected void btnMenuEdit_Click(object sender, EventArgs e) { if (Grid1.SelectedRowIndexArray.Length == 0) { Alert.ShowInTop("请至少选择一条记录!", MessageBoxIcon.Warning); return; } string id = Grid1.SelectedRowID; var actReview = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(id); if (actReview.State < Const.ContractReviewing) { Alert.ShowInTop("还未创建审批流无法重新提交!", MessageBoxIcon.Warning); return; } actReview.State = Const.ContractReviewing; if (actReview.CreateUser != this.CurrUser.PersonId) { string name = Person_PersonsService.GetPersonsNameById(actReview.CreateUser); Alert.ShowInTop("!此审批不是您创建,无法重新提交【创建者:" + name + "】", MessageBoxIcon.Warning); return; } BLL.PHTGL_ActionPlanReviewService.UpdatePHTGL_ActionPlanReview(actReview); /////改变实施计划表状态 //var model = PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(actReview.ActionPlanID); //model.State = Const.ContractReviewing; //PHTGL_ActionPlanFormationService.UpdatePHTGL_ActionPlanFormation(model); ///删除历史审批记录 // PHTGL_ApproveService.DeletePHTGL_ApproveBycontractId(id); var _ActFormation = BLL.PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(actReview.ActionPlanID); //创建第一节点审批信息 var ApproveManModels = PHTGL_ActionPlanReviewService.GetApproveManModels(_ActFormation.ProjectID, actReview.ActionPlanReviewId); Model.PHTGL_Approve _Approve = new Model.PHTGL_Approve(); _Approve.ApproveId = SQLHelper.GetNewID(typeof(Model.PHTGL_Approve)); _Approve.ContractId = actReview.ActionPlanReviewId; _Approve.ApproveMan = ApproveManModels.Find(x => x.Number == 1).userid; _Approve.ApproveDate = ""; _Approve.State = 0; _Approve.IsAgree = 0; _Approve.ApproveIdea = ""; _Approve.ApproveType = ApproveManModels.Find(x => x.Number == 1).Rolename; _Approve.IsPushOa = 0; _Approve.ApproveForm = PHTGL_ApproveService.ActionPlanReview; BLL.PHTGL_ApproveService.AddPHTGL_Approve(_Approve); OAWebSevice.Pushoa(); ShowNotify("重新提交成功!", MessageBoxIcon.Success); BindGrid(); } /// /// 编辑数据方法 /// private void EditData() { if (Grid1.SelectedRowIndexArray.Length == 0) { Alert.ShowInTop("请至少选择一条记录!", MessageBoxIcon.Warning); return; } string id = Grid1.SelectedRowID; PageContext.RegisterStartupScript(Window1.GetShowReference(String.Format("ActionPlanReviewDetail.aspx?ActionPlanReviewId={0}", id, "编辑 - "))); } #endregion #region 添加 protected void btnNew_Click(object sender, EventArgs e) { if (Grid1.SelectedRowIndexArray.Length == 0) { Alert.ShowInTop("请至少选择一条记录!", MessageBoxIcon.Warning); return; } string id = Grid1.SelectedRowID; PageContext.RegisterStartupScript(Window1.GetShowReference(String.Format("ActionPlanReviewEdit.aspx?ActionPlanReviewId={0}", id, "编辑 - "))); } #endregion #region 删除 /// /// 右键删除事件 /// /// /// protected void btnMenuDelete_Click(object sender, EventArgs e) { if (Grid1.SelectedRowIndexArray.Length > 0) { bool isShow = false; if (Grid1.SelectedRowIndexArray.Length == 1) { isShow = true; } foreach (int rowIndex in Grid1.SelectedRowIndexArray) { string rowID = Grid1.DataKeys[rowIndex][0].ToString(); if (this.judgementDelete(rowID, isShow)) { var p = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(rowID); if (p != null) { BLL.LogService.AddSys_Log(this.CurrUser, p.CreateUser, p.ActionPlanID, BLL.Const.ActionPlanReview, BLL.Const.BtnDelete); PHTGL_ApproveService.DeletePHTGL_ApproveBycontractId(rowID); BLL.PHTGL_ActionPlanReviewService.DeletePHTGL_ActionPlanReviewById(rowID); } } } BindGrid(); ShowNotify("删除数据成功!", MessageBoxIcon.Success); } } /// /// 判断是否可以删除 /// /// private bool judgementDelete(string id, bool isShow) { string content = string.Empty; if (string.IsNullOrEmpty(content)) { return true; } else { if (isShow) { Alert.ShowInTop(content); } return false; } } #endregion #region 获取按钮权限 /// /// 获取按钮权限 /// /// /// private void GetButtonPower() { if (Request.Params["value"] == "0") { return; } var buttonList = CommonService.GetAllButtonList(CurrUser.LoginProjectId, CurrUser.PersonId, Const.ActionPlanReview); if (buttonList.Count() > 0) { if (buttonList.Contains(Const.BtnAdd)) { btnNew.Hidden = false; } //if (buttonList.Contains(Const.BtnDelete)) //{ // btnDelete.Hidden = false; //} } } #endregion #region 打印 /// /// 打印 /// /// /// protected void btnPrinter_Click(object sender, EventArgs e) { if (Grid1.SelectedRowIndexArray.Length == 0) { Alert.ShowInTop("请至少选择一条记录!", MessageBoxIcon.Warning); return; } string Id = Grid1.SelectedRowID; var Act = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(Id); if (Act == null) { Alert.ShowInTop("还未创建审批流无法导出!", MessageBoxIcon.Warning); return; } string ActionPlanID = Act.ActionPlanID; //ActionPlanFormation actionPlanFormation = new ActionPlanFormation(); //actionPlanFormation.Print(ActionPlanID); BLL.PHTGL_ActionPlanFormationService.PrintFile( ActionPlanID); } #endregion } }