249 lines
11 KiB
C#
249 lines
11 KiB
C#
using BLL;
|
|
using Model;
|
|
using System;
|
|
using System.Collections.Generic;
|
|
using System.Data;
|
|
using System.Data.SqlClient;
|
|
|
|
namespace FineUIPro.Web.PHTGL.BiddingManagement
|
|
{
|
|
public partial class ActionPlanReviewEdit : PageBase
|
|
{
|
|
#region 定义属性
|
|
/// <summary>
|
|
/// 审批人字典
|
|
/// </summary>
|
|
public Dictionary<int, string> Dic_ApproveMan
|
|
{
|
|
get
|
|
{
|
|
return (Dictionary<int, string>)ViewState["Dic_ApproveMan"];
|
|
}
|
|
set
|
|
{
|
|
ViewState["Dic_ApproveMan"] = value;
|
|
}
|
|
}
|
|
public List<ApproveManModel> ApproveManModels
|
|
{
|
|
get
|
|
{
|
|
return (List<ApproveManModel>)Session["ApproveManModels"];
|
|
}
|
|
set
|
|
{
|
|
Session["ApproveManModels"] = value;
|
|
}
|
|
}
|
|
public string ActionPlanReviewId
|
|
{
|
|
get
|
|
{
|
|
return (string)ViewState["ActionPlanReviewId"];
|
|
}
|
|
set
|
|
{
|
|
ViewState["ActionPlanReviewId"] = value;
|
|
}
|
|
}
|
|
#endregion
|
|
protected void Page_Load(object sender, EventArgs e)
|
|
{
|
|
if (!IsPostBack)
|
|
{
|
|
this.btnClose.OnClientClick = ActiveWindow.GetHideReference();
|
|
ActionPlanReviewId = Request.Params["ActionPlanReviewId"];
|
|
#region 绑定下拉列表
|
|
BLL.DepartService.InitDepartDropDownList(DropDepart, true);
|
|
/// 绑定施工管理部正副主任
|
|
BLL.Person_PersonsService.InitUserProjectIdUnitIdRoleIdDropDownList(Approval_Construction, null, CurrUser.UnitId, Const.ConstructionMinister + "," + Const.ConstructionViceMinister, false);
|
|
|
|
BLL.Person_PersonsService.InitUserProjectIdUnitIdRoleIdDropDownList(DropConstructionManager, null, Const.UnitId_SEDIN, null, true);
|
|
BLL.Person_PersonsService.InitUserProjectIdUnitIdRoleIdDropDownList(DropPreliminaryMan, null, Const.UnitId_SEDIN, null, true);
|
|
BLL.Person_PersonsService.InitUserProjectIdUnitIdRoleIdDropDownList(DropProjectManager, null, Const.UnitId_SEDIN, null, true);
|
|
BLL.Person_PersonsService.InitUserProjectIdUnitIdRoleIdDropDownList(DropDeputyGeneralManager, null, this.CurrUser.UnitId, Const.DeputyGeneralManager, false);
|
|
if (PHTGL_ActionPlanReviewService.IsSpecialProject(this.CurrUser.LoginProjectId))
|
|
{
|
|
BLL.Person_PersonsService.InitUserProjectIdUnitIdRoleIdDropDownList(Approval_Construction, null, CurrUser.UnitId, Const.ConstructionLabor, false);
|
|
|
|
DropConstructionManager.Label = "现场执行经理";
|
|
Approval_Construction.Label = "主办部门负责人";
|
|
DropProjectManager.Label = "项目经理";
|
|
}
|
|
#endregion
|
|
|
|
BindGrid();
|
|
BindForm();
|
|
var newmodel = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
|
|
if (newmodel != null)
|
|
{
|
|
if (newmodel.State > Const.ContractCreat_Complete)
|
|
{
|
|
this.btnSave.Hidden = true;
|
|
this.btnSubmit.Hidden = true;
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
private void BindForm()
|
|
{
|
|
var act = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
|
|
drpProjectId.Value = Convert.ToString(act.ActionPlanID);
|
|
Approval_Construction.SelectedValue = Convert.ToString(act.Approval_Construction);
|
|
DropConstructionManager.SelectedValue = Convert.ToString(act.ConstructionManager);
|
|
DropPreliminaryMan.SelectedValue = Convert.ToString(act.PreliminaryMan);
|
|
DropProjectManager.SelectedValue = Convert.ToString(act.ProjectManager);
|
|
DropDeputyGeneralManager.SelectedValue = Convert.ToString(act.DeputyGeneralManager);
|
|
DropDepart.SelectedValue = Convert.ToString(act.DepartId);
|
|
}
|
|
/// <summary>
|
|
/// 数据绑定
|
|
/// </summary>
|
|
private void BindGrid()
|
|
{
|
|
string strSql = @"SELECT Act.ActionPlanID
|
|
,Act.ActionPlanCode
|
|
,Pro.ProjectName as Name
|
|
,Pro.ProjectCode
|
|
,U.PersonName as CreatUser
|
|
,Act.CreateTime
|
|
,Act.ProjectID
|
|
,Act.ProjectName
|
|
,Act.Unit
|
|
,Act.ConstructionSite "
|
|
+ @" FROM PHTGL_ActionPlanFormation AS Act "
|
|
+ @" LEFT JOIN Person_Persons AS U ON U.PersonId = Act.CreatUser "
|
|
+ @" LEFT JOIN Base_Project AS Pro ON Pro.ProjectId = Act.ProjectID WHERE 1=1 and Act.State=@ContractCreat_Complete";
|
|
List<SqlParameter> listStr = new List<SqlParameter>();
|
|
listStr.Add(new SqlParameter("@ContractCreat_Complete", Const.ContractCreat_Complete));
|
|
|
|
if (!(this.CurrUser.PersonId == Const.sysglyId))
|
|
{
|
|
strSql += " and Act.ProjectID =@ProjectId";
|
|
|
|
listStr.Add(new SqlParameter("@ProjectId", this.CurrUser.LoginProjectId));
|
|
}
|
|
SqlParameter[] parameter = listStr.ToArray();
|
|
DataTable tb = SQLHelper.GetDataTableRunText(strSql, parameter);
|
|
Grid1.RecordCount = tb.Rows.Count;
|
|
// var table = this.GetPagedDataTable(Grid1, tb);
|
|
Grid1.DataSource = tb;
|
|
Grid1.DataBind();
|
|
}
|
|
|
|
private bool Save()
|
|
{
|
|
bool isOk = false;
|
|
|
|
if (string.IsNullOrEmpty(drpProjectId.Value))
|
|
{
|
|
ShowNotify("请选择合同", MessageBoxIcon.Warning);
|
|
return isOk;
|
|
}
|
|
if (DropDepart.SelectedValue == Const._Null)
|
|
{
|
|
ShowNotify("请选择部门!", MessageBoxIcon.Warning);
|
|
return false;
|
|
|
|
}
|
|
if (Approval_Construction.SelectedValue == Const._Null)
|
|
{
|
|
ShowNotify("请选择部门审批人员", MessageBoxIcon.Warning);
|
|
return isOk;
|
|
|
|
}
|
|
|
|
//0 是审批中 1是成功 2是失败
|
|
Model.PHTGL_ActionPlanReview newmodel = new Model.PHTGL_ActionPlanReview();
|
|
newmodel.ActionPlanReviewId = ActionPlanReviewId;
|
|
newmodel.ActionPlanID = drpProjectId.Value;
|
|
newmodel.Approval_Construction = Approval_Construction.SelectedValue;
|
|
newmodel.State = Const.ContractCreat_Complete;
|
|
newmodel.CreateUser = this.CurrUser.PersonId;
|
|
newmodel.ConstructionManager = DropConstructionManager.SelectedValue;
|
|
newmodel.PreliminaryMan = DropPreliminaryMan.SelectedValue;
|
|
newmodel.ProjectManager = DropProjectManager.SelectedValue;
|
|
newmodel.DeputyGeneralManager = DropDeputyGeneralManager.SelectedValue;
|
|
newmodel.DepartId = DropDepart.SelectedValue;
|
|
BLL.PHTGL_ActionPlanReviewService.UpdatePHTGL_ActionPlanReview(newmodel);
|
|
isOk = true;
|
|
return isOk;
|
|
|
|
}
|
|
private void CreateApprove()
|
|
{
|
|
var newmodel = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
|
|
var _Act = BLL.PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(newmodel.ActionPlanID);
|
|
Dic_ApproveMan = PHTGL_ActionPlanReviewService.Get_DicApproveman(_Act.ProjectID, newmodel.ActionPlanReviewId);
|
|
ApproveManModels = PHTGL_ActionPlanReviewService.GetApproveManModels(_Act.ProjectID, newmodel.ActionPlanReviewId);
|
|
//创建第一节点审批信息
|
|
Model.PHTGL_Approve _Approve = new Model.PHTGL_Approve();
|
|
_Approve.ApproveId = SQLHelper.GetNewID(typeof(Model.PHTGL_Approve));
|
|
_Approve.ContractId = newmodel.ActionPlanReviewId;
|
|
_Approve.ApproveMan = ApproveManModels.Find(e => e.Number == 1).userid;
|
|
_Approve.ApproveDate = "";
|
|
_Approve.State = 0;
|
|
_Approve.IsAgree = 0;
|
|
_Approve.ApproveIdea = "";
|
|
_Approve.ApproveType = ApproveManModels.Find(e => e.Number == 1).Rolename;
|
|
_Approve.IsPushOa = 0;
|
|
_Approve.ApproveForm = PHTGL_ApproveService.ActionPlanReview;
|
|
|
|
BLL.PHTGL_ApproveService.AddPHTGL_Approve(_Approve);
|
|
}
|
|
|
|
protected void btnSave_Click(object sender, EventArgs e)
|
|
{
|
|
if (Save())
|
|
{
|
|
ShowNotify("保存成功!", MessageBoxIcon.Success);
|
|
PageContext.RegisterStartupScript(ActiveWindow.GetHideRefreshReference());
|
|
}
|
|
|
|
}
|
|
|
|
protected void btnSubmit_Click(object sender, EventArgs e)
|
|
{
|
|
if (Save())
|
|
{
|
|
CreateApprove();
|
|
var model1 = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
|
|
model1.State = Const.ContractReviewing;
|
|
PHTGL_ActionPlanReviewService.UpdatePHTGL_ActionPlanReview(model1);
|
|
|
|
//model2.State= Const.ContractReviewing;
|
|
//PHTGL_ActionPlanFormationService.UpdatePHTGL_ActionPlanFormation(model2);
|
|
OAWebSevice.Pushoa();
|
|
PageContext.RegisterStartupScript(ActiveWindow.GetHideRefreshReference());
|
|
}
|
|
}
|
|
|
|
#region DropDownList下拉选择事件
|
|
/// <summary>
|
|
/// 选择项目Id获取会签评审人员信息
|
|
/// </summary>
|
|
/// <param name="sender"></param>
|
|
/// <param name="e"></param>
|
|
protected void DropDownBox1_TextChanged(object sender, EventArgs e)
|
|
{
|
|
if (this.drpProjectId.Value != BLL.Const._Null)
|
|
{
|
|
Model.PHTGL_ActionPlanFormation table = BLL.PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(this.drpProjectId.Value);
|
|
string UnitId = ProjectService.GetProjectByProjectId(table.ProjectID).UnitId;
|
|
|
|
//施工经理
|
|
this.DropConstructionManager.SelectedValue = BLL.SitePerson_PersonService.GetPersonIdByProjectIdRoleID(table.ProjectID, BLL.Const.ConstructionManager);
|
|
|
|
//项目经理
|
|
this.DropProjectManager.SelectedValue = BLL.SitePerson_PersonService.GetPersonIdByProjectIdRoleID(table.ProjectID, BLL.Const.ProjectManager);
|
|
|
|
//分管副总经理
|
|
this.DropDeputyGeneralManager.SelectedValue = BLL.SitePerson_PersonService.GetPersonIdByProjectIdRoleID(UnitId, BLL.Const.DeputyGeneralManager);
|
|
|
|
}
|
|
|
|
}
|
|
#endregion
|
|
}
|
|
} |