SGGL_SHJ/DataBase/版本日志/SGGLDB_V2023-10-20.sql

125 lines
7.4 KiB
Transact-SQL

CREATE TABLE [dbo].[ZHGL_ConstructionLogWorkEfficiencyMonth](
[ConstructionLogWorkEfficiencyMonthId] [nvarchar](50) NOT NULL,
[ProjectId] [nvarchar](50) NULL,
[Month] [datetime] NULL,
[ContractTrackId] [varchar](50) NULL,
[PhysicalCompletionQuantity] [decimal](18, 2) NULL,
[MaterialConsumption] [decimal](18, 2) NULL,
[UnitOfMeasurement] [nvarchar](50) NULL,
[Type] [nvarchar](20) NULL,
[TypeId] [nvarchar](50) NULL,
[ConsumeHours] [decimal](18, 2) NULL,
[WorkEfficiency] [decimal](18, 2) NULL,
CONSTRAINT [PK_ZHGL_ConstructionLogWorkEfficiencyMonth] PRIMARY KEY CLUSTERED
(
[ConstructionLogWorkEfficiencyMonthId] ASC
)WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY]
) ON [PRIMARY]
GO
SET ANSI_PADDING OFF
GO
ALTER TABLE [dbo].[ZHGL_ConstructionLogWorkEfficiencyMonth] WITH CHECK ADD CONSTRAINT [FK_ZHGL_ConstructionLogWorkEfficiencyMonth_Base_Project] FOREIGN KEY([ProjectId])
REFERENCES [dbo].[Base_Project] ([ProjectId])
GO
ALTER TABLE [dbo].[ZHGL_ConstructionLogWorkEfficiencyMonth] CHECK CONSTRAINT [FK_ZHGL_ConstructionLogWorkEfficiencyMonth_Base_Project]
GO
ALTER TABLE [dbo].[ZHGL_ConstructionLogWorkEfficiencyMonth] WITH CHECK ADD CONSTRAINT [FK_ZHGL_ConstructionLogWorkEfficiencyMonth_PHTGL_ContractTrack] FOREIGN KEY([ContractTrackId])
REFERENCES [dbo].[PHTGL_ContractTrack] ([Id])
GO
ALTER TABLE [dbo].[ZHGL_ConstructionLogWorkEfficiencyMonth] CHECK CONSTRAINT [FK_ZHGL_ConstructionLogWorkEfficiencyMonth_PHTGL_ContractTrack]
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'Ö÷¼ü' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyMonth', @level2type=N'COLUMN',@level2name=N'ConstructionLogWorkEfficiencyMonthId'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÏîÄ¿Id' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyMonth', @level2type=N'COLUMN',@level2name=N'ProjectId'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'Ô·Ý' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyMonth', @level2type=N'COLUMN',@level2name=N'Month'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ºÏͬId' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyMonth', @level2type=N'COLUMN',@level2name=N'ContractTrackId'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ʵÎïÍê³ÉÁ¿' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyMonth', @level2type=N'COLUMN',@level2name=N'PhysicalCompletionQuantity'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'²ÄÁÏÏûºÄÁ¿' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyMonth', @level2type=N'COLUMN',@level2name=N'MaterialConsumption'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'µ¥Î»' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyMonth', @level2type=N'COLUMN',@level2name=N'UnitOfMeasurement'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÀàÐÍ£¨È˹¤/»úе£©' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyMonth', @level2type=N'COLUMN',@level2name=N'Type'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÀàÐÍId' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyMonth', @level2type=N'COLUMN',@level2name=N'TypeId'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÏûºÄ¹¤/̨ʱ' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyMonth', @level2type=N'COLUMN',@level2name=N'ConsumeHours'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'¹¤Ð§' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyMonth', @level2type=N'COLUMN',@level2name=N'WorkEfficiency'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'¹¤Ð§ÔÂͳ¼ÆÊý¾Ý' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyMonth'
GO
CREATE TABLE [dbo].[ZHGL_ConstructionLogWorkEfficiencyProject](
[ConstructionLogWorkEfficiencyProjectId] [nvarchar](50) NOT NULL,
[ProjectId] [nvarchar](50) NULL,
[Type] [nvarchar](20) NULL,
[TypeId] [nvarchar](50) NULL,
[UnitOfMeasurement] [nvarchar](50) NULL,
[BaseWorkEfficiency] [decimal](18, 2) NULL,
[AvgWorkEfficiency] [decimal](18, 2) NULL,
CONSTRAINT [PK_ZHGL_ConstructionLogWorkEfficiencyProject] PRIMARY KEY CLUSTERED
(
[ConstructionLogWorkEfficiencyProjectId] ASC
)WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF, ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) ON [PRIMARY]
) ON [PRIMARY]
GO
ALTER TABLE [dbo].[ZHGL_ConstructionLogWorkEfficiencyProject] WITH CHECK ADD CONSTRAINT [FK_ZHGL_ConstructionLogWorkEfficiencyProject_Base_Project] FOREIGN KEY([ProjectId])
REFERENCES [dbo].[Base_Project] ([ProjectId])
GO
ALTER TABLE [dbo].[ZHGL_ConstructionLogWorkEfficiencyProject] CHECK CONSTRAINT [FK_ZHGL_ConstructionLogWorkEfficiencyProject_Base_Project]
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'Ö÷¼ü' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyProject', @level2type=N'COLUMN',@level2name=N'ConstructionLogWorkEfficiencyProjectId'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÏîÄ¿Id' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyProject', @level2type=N'COLUMN',@level2name=N'ProjectId'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÀàÐÍ£¨È˹¤/»úе£©' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyProject', @level2type=N'COLUMN',@level2name=N'Type'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÀàÐÍId' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyProject', @level2type=N'COLUMN',@level2name=N'TypeId'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'µ¥Î»' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyProject', @level2type=N'COLUMN',@level2name=N'UnitOfMeasurement'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'¹¤Ð§»ù×¼' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyProject', @level2type=N'COLUMN',@level2name=N'BaseWorkEfficiency'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÏîÄ¿µ±Ç°Æ½¾ù¹¤Ð§' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyProject', @level2type=N'COLUMN',@level2name=N'AvgWorkEfficiency'
GO
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'ÏîÄ¿¹¤Ð§±í' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'ZHGL_ConstructionLogWorkEfficiencyProject'
GO