Files
SGGL_SHJ/SGGL/FineUIPro.Web/PHTGL/BiddingManagement/ActionPlanReview.aspx.cs
T

445 lines
17 KiB
C#

namespace FineUIPro.Web.PHTGL.BiddingManagement
{
using BLL;
using System;
using System.Collections.Generic;
using System.Data;
using System.Data.SqlClient;
using System.Linq;
public partial class ActionPlanReview : PageBase
{
#region
/// <summary>
/// 加载页面
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Page_Load(object sender, EventArgs e)
{
if (!IsPostBack)
{
Funs.DropDownPageSize(this.ddlPageSize);
this.DropState.DataValueField = "Value";
DropState.DataTextField = "Text";
DropState.DataSource = BLL.DropListService.GetState();
DropState.DataBind();
Funs.FineUIPleaseSelect(DropState);
DropState.SelectedValueArray = new string[]
{
Const.ContractCreat_Complete.ToString (),
Const.ContractReviewing.ToString (),
Const.ContractReview_Refuse.ToString()
};
GetButtonPower();
BindGrid();
}
}
#endregion
#region
/// <summary>
/// 数据绑定
/// </summary>
private void BindGrid()
{
string strSql = @"SELECT APR.ActionPlanReviewId
,APR.ActionPlanID
,Act.ActionPlanCode
,Pro.ProjectName
,Pro.ProjectCode
,Act.ProjectShortName as Name
,Act.EPCCode
, (CASE APR.State
WHEN @ContractCreat_Complete THEN '编制完成'
WHEN @ContractReviewing THEN '审批中'
WHEN @ContractReview_Complete THEN '审批完成'
WHEN @ContractReview_Refuse THEN '审批被拒'END) AS State
,ApproveType =stuff((select ','+ ApproveType from PHTGL_Approve app2 where app2.ContractId = APR.ActionPlanReviewId and app2 .state =0 for xml path('')), 1, 1, '')
,APR.Approval_Construction
,Act.CreateTime
,U.PersonName AS CreateUser "
+ @" FROM PHTGL_ActionPlanReview AS APR "
+ @" LEFT JOIN Person_Persons AS U ON U.PersonId = APR.CreateUser "
+ @" LEFT JOIN PHTGL_ActionPlanFormation AS Act ON Act.ActionPlanID=APR.ActionPlanID"
+ @" LEFT JOIN Base_Project AS Pro ON Pro.ProjectId = Act.ProjectID WHERE 1=1 ";
List<SqlParameter> listStr = new List<SqlParameter>();
listStr.Add(new SqlParameter("@ContractCreat_Complete", Const.ContractCreat_Complete));
listStr.Add(new SqlParameter("@ContractReviewing", Const.ContractReviewing));
listStr.Add(new SqlParameter("@ContractReview_Complete", Const.ContractReview_Complete));
listStr.Add(new SqlParameter("@ContractReview_Refuse", Const.ContractReview_Refuse));
if (!(this.CurrUser.PersonId == Const.sysglyId))
{
strSql += " and Act.ProjectID =@ProjectId";
listStr.Add(new SqlParameter("@ProjectId", this.CurrUser.LoginProjectId));
}
if (!string.IsNullOrEmpty(txtActionPlanCode.Text))
{
strSql += " and Act.ActionPlanCode like @ActionPlanCode ";
listStr.Add(new SqlParameter("@ActionPlanCode", "%" + txtActionPlanCode.Text + "%"));
}
if (DropState.SelectedItemArray.Length > 0)
{
strSql += string.Format(" and APR.State in ({0}) ", string.Join(",", DropState.SelectedValueArray));
}
SqlParameter[] parameter = listStr.ToArray();
DataTable tb = SQLHelper.GetDataTableRunText(strSql, parameter);
Grid1.RecordCount = tb.Rows.Count;
var table = this.GetPagedDataTable(Grid1, tb);
Grid1.DataSource = table;
Grid1.DataBind();
}
#endregion
#region
/// <summary>
/// 改变索引事件
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Grid1_PageIndexChange(object sender, GridPageEventArgs e)
{
BindGrid();
}
/// <summary>
/// 分页下拉选择事件
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void ddlPageSize_SelectedIndexChanged(object sender, EventArgs e)
{
Grid1.PageSize = Convert.ToInt32(ddlPageSize.SelectedValue);
BindGrid();
}
/// <summary>
/// 排序
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Grid1_Sort(object sender, FineUIPro.GridSortEventArgs e)
{
BindGrid();
}
protected void Grid1_RowCommand(object sender, GridCommandEventArgs e)
{
object[] keys = Grid1.DataKeys[e.RowIndex];
string fileId = string.Empty;
if (keys == null)
{
return;
}
else
{
fileId = keys[0].ToString();
}
if (e.CommandName == "LooK")
{
string id = fileId;
var Act = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(id);
PageContext.RegisterStartupScript(Window1.GetShowReference(String.Format("ActionPlanFormationEdit.aspx?ActionPlanID={0}", Act.ActionPlanID, "编辑 - ")));
return;
}
}
#endregion
#region
/// <summary>
/// 关闭弹出窗体
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Window1_Close(object sender, WindowCloseEventArgs e)
{
BindGrid();
}
#endregion
#region
/// <summary>
/// 查询按钮
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void btnSearch_Click(object sender, EventArgs e)
{
BindGrid();
OAWebSevice.Pushoa();
}
protected void btnRset_Click(object sender, EventArgs e)
{
txtActionPlanCode.Text = "";
DropState.SelectedValueArray = new string[] {
Const.ContractCreat_Complete.ToString (),
Const.ContractReviewing.ToString (),
Const.ContractReview_Refuse.ToString()
};
BindGrid();
}
protected void btnQueryApprove_Click(object sender, EventArgs e)
{
this.EditData();
}
#endregion
#region
/// <summary>
/// 双击事件
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Grid1_RowDoubleClick(object sender, GridRowClickEventArgs e)
{
this.EditData();
}
/// <summary>
/// 单击事件EnableRowClickEvent="false"未启用
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Grid1_RowClick(object sender, GridRowClickEventArgs e)
{
string id = Grid1.SelectedRowID;
var actReview = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(id);
if (actReview.State == Const.ContractReview_Refuse)
{
btnEditActPlan.Hidden = false;
}
else
{
btnEditActPlan.Hidden = true;
}
}
protected void btnEditActPlan_Click(object sender, EventArgs e)
{
if (Grid1.SelectedRowIndexArray.Length == 0)
{
Alert.ShowInTop("请至少选择一条记录!", MessageBoxIcon.Warning);
return;
}
string id = Grid1.SelectedRowID;
string actplanId = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(id).ActionPlanID;
var model = PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(actplanId);
model.State = Const.ContractCreating;
PHTGL_ActionPlanFormationService.UpdatePHTGL_ActionPlanFormation(model);
PageContext.RegisterStartupScript(Window1.GetShowReference(String.Format("ActionPlanFormationEdit.aspx?ActionPlanID={0}", actplanId, "编辑 - ")));
}
/// <summary>
/// 重新提交
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void btnMenuEdit_Click(object sender, EventArgs e)
{
if (Grid1.SelectedRowIndexArray.Length == 0)
{
Alert.ShowInTop("请至少选择一条记录!", MessageBoxIcon.Warning);
return;
}
string id = Grid1.SelectedRowID;
var actReview = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(id);
if (actReview.State < Const.ContractReviewing)
{
Alert.ShowInTop("还未创建审批流无法重新提交!", MessageBoxIcon.Warning);
return;
}
actReview.State = Const.ContractReviewing;
if (actReview.CreateUser != this.CurrUser.PersonId)
{
string name = Person_PersonsService.GetPersonsNameById(actReview.CreateUser);
Alert.ShowInTop("!此审批不是您创建,无法重新提交【创建者:" + name + "】", MessageBoxIcon.Warning);
return;
}
BLL.PHTGL_ActionPlanReviewService.UpdatePHTGL_ActionPlanReview(actReview);
/////改变实施计划表状态
//var model = PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(actReview.ActionPlanID);
//model.State = Const.ContractReviewing;
//PHTGL_ActionPlanFormationService.UpdatePHTGL_ActionPlanFormation(model);
///删除历史审批记录
// PHTGL_ApproveService.DeletePHTGL_ApproveBycontractId(id);
var _ActFormation = BLL.PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(actReview.ActionPlanID);
//创建第一节点审批信息
var ApproveManModels = PHTGL_ActionPlanReviewService.GetApproveManModels(_ActFormation.ProjectID, actReview.ActionPlanReviewId);
Model.PHTGL_Approve _Approve = new Model.PHTGL_Approve();
_Approve.ApproveId = SQLHelper.GetNewID(typeof(Model.PHTGL_Approve));
_Approve.ContractId = actReview.ActionPlanReviewId;
_Approve.ApproveMan = ApproveManModels.Find(x => x.Number == 1).userid;
_Approve.ApproveDate = "";
_Approve.State = 0;
_Approve.IsAgree = 0;
_Approve.ApproveIdea = "";
_Approve.ApproveType = ApproveManModels.Find(x => x.Number == 1).Rolename;
_Approve.IsPushOa = 0;
_Approve.ApproveForm = PHTGL_ApproveService.ActionPlanReview;
BLL.PHTGL_ApproveService.AddPHTGL_Approve(_Approve);
OAWebSevice.Pushoa();
ShowNotify("重新提交成功!", MessageBoxIcon.Success);
BindGrid();
}
/// <summary>
/// 编辑数据方法
/// </summary>
private void EditData()
{
if (Grid1.SelectedRowIndexArray.Length == 0)
{
Alert.ShowInTop("请至少选择一条记录!", MessageBoxIcon.Warning);
return;
}
string id = Grid1.SelectedRowID;
PageContext.RegisterStartupScript(Window1.GetShowReference(String.Format("ActionPlanReviewDetail.aspx?ActionPlanReviewId={0}", id, "编辑 - ")));
}
#endregion
#region
protected void btnNew_Click(object sender, EventArgs e)
{
if (Grid1.SelectedRowIndexArray.Length == 0)
{
Alert.ShowInTop("请至少选择一条记录!", MessageBoxIcon.Warning);
return;
}
string id = Grid1.SelectedRowID;
PageContext.RegisterStartupScript(Window1.GetShowReference(String.Format("ActionPlanReviewEdit.aspx?ActionPlanReviewId={0}", id, "编辑 - ")));
}
#endregion
#region
/// <summary>
/// 右键删除事件
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void btnMenuDelete_Click(object sender, EventArgs e)
{
if (Grid1.SelectedRowIndexArray.Length > 0)
{
bool isShow = false;
if (Grid1.SelectedRowIndexArray.Length == 1)
{
isShow = true;
}
foreach (int rowIndex in Grid1.SelectedRowIndexArray)
{
string rowID = Grid1.DataKeys[rowIndex][0].ToString();
if (this.judgementDelete(rowID, isShow))
{
var p = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(rowID);
if (p != null)
{
BLL.LogService.AddSys_Log(this.CurrUser, p.CreateUser, p.ActionPlanID, BLL.Const.ActionPlanReview, BLL.Const.BtnDelete);
PHTGL_ApproveService.DeletePHTGL_ApproveBycontractId(rowID);
BLL.PHTGL_ActionPlanReviewService.DeletePHTGL_ActionPlanReviewById(rowID);
}
}
}
BindGrid();
ShowNotify("删除数据成功!", MessageBoxIcon.Success);
}
}
/// <summary>
/// 判断是否可以删除
/// </summary>
/// <returns></returns>
private bool judgementDelete(string id, bool isShow)
{
string content = string.Empty;
if (string.IsNullOrEmpty(content))
{
return true;
}
else
{
if (isShow)
{
Alert.ShowInTop(content);
}
return false;
}
}
#endregion
#region
/// <summary>
/// 获取按钮权限
/// </summary>
/// <param name="button"></param>
/// <returns></returns>
private void GetButtonPower()
{
if (Request.Params["value"] == "0")
{
return;
}
var buttonList = CommonService.GetAllButtonList(CurrUser.LoginProjectId, CurrUser.PersonId, Const.ActionPlanReview);
if (buttonList.Count() > 0)
{
if (buttonList.Contains(Const.BtnAdd))
{
btnNew.Hidden = false;
}
//if (buttonList.Contains(Const.BtnDelete))
//{
// btnDelete.Hidden = false;
//}
}
}
#endregion
#region
/// <summary>
/// 打印
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void btnPrinter_Click(object sender, EventArgs e)
{
if (Grid1.SelectedRowIndexArray.Length == 0)
{
Alert.ShowInTop("请至少选择一条记录!", MessageBoxIcon.Warning);
return;
}
string Id = Grid1.SelectedRowID;
var Act = PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(Id);
if (Act == null)
{
Alert.ShowInTop("还未创建审批流无法导出!", MessageBoxIcon.Warning);
return;
}
string ActionPlanID = Act.ActionPlanID;
//ActionPlanFormation actionPlanFormation = new ActionPlanFormation();
//actionPlanFormation.Print(ActionPlanID);
BLL.PHTGL_ActionPlanFormationService.PrintFile( ActionPlanID);
}
#endregion
}
}