315 lines
12 KiB
C#
315 lines
12 KiB
C#
using BLL;
|
|
using System;
|
|
using System.Collections.Generic;
|
|
using System.Data;
|
|
using System.Data.SqlClient;
|
|
|
|
namespace FineUIPro.Web.PHTGL.BiddingManagement
|
|
{
|
|
public partial class ActionPlanReviewDetail : PageBase
|
|
{
|
|
#region 定义属性
|
|
/// <summary>
|
|
/// 合同ID
|
|
/// </summary>
|
|
public string ActionPlanReviewId
|
|
{
|
|
get
|
|
{
|
|
return (string)ViewState["ActionPlanReviewId"];
|
|
}
|
|
set
|
|
{
|
|
ViewState["ActionPlanReviewId"] = value;
|
|
}
|
|
}
|
|
/// <summary>
|
|
/// 最末的审批节点
|
|
/// </summary>
|
|
public int EndApproveType
|
|
{
|
|
get
|
|
{
|
|
return (int)ViewState["EndApproveType"];
|
|
}
|
|
set
|
|
{
|
|
ViewState["EndApproveType"] = value;
|
|
}
|
|
}
|
|
/// <summary>
|
|
/// 审批人字典
|
|
/// </summary>
|
|
public Dictionary<int, string> Dic_ApproveMan
|
|
{
|
|
get
|
|
{
|
|
return (Dictionary<int, string>)ViewState["Dic_ApproveMan"];
|
|
}
|
|
set
|
|
{
|
|
ViewState["Dic_ApproveMan"] = value;
|
|
}
|
|
}
|
|
public Model.PHTGL_Approve pHTGL_Approve
|
|
{
|
|
get
|
|
{
|
|
return (Model.PHTGL_Approve)Session["pHTGL_Approve"];
|
|
}
|
|
set
|
|
{
|
|
Session["pHTGL_Approve"] = value;
|
|
}
|
|
}
|
|
public List<ApproveManModel> ApproveManModels
|
|
{
|
|
get
|
|
{
|
|
return (List<ApproveManModel>)Session["ApproveManModels"];
|
|
}
|
|
set
|
|
{
|
|
Session["ApproveManModels"] = value;
|
|
}
|
|
}
|
|
#endregion
|
|
|
|
#region 加载
|
|
protected void Page_Load(object sender, EventArgs e)
|
|
{
|
|
if (!IsPostBack)
|
|
{
|
|
ActionPlanReviewId = Request.Params["ActionPlanReviewId"];
|
|
|
|
//获取招标实施计划基本信息
|
|
var _ActionPlanReview = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
|
|
var _ActionPlanFormation = BLL.PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(_ActionPlanReview.ActionPlanID);
|
|
//获取审批人字典
|
|
ApproveManModels = PHTGL_ActionPlanReviewService.GetApproveManModels(_ActionPlanFormation.ProjectID, ActionPlanReviewId);
|
|
EndApproveType = ApproveManModels.Count;
|
|
//获取当前登录人审批信息
|
|
pHTGL_Approve = BLL.PHTGL_ApproveService.GetPHTGL_ApproveByUserId(ActionPlanReviewId, this.CurrUser.PersonId);
|
|
|
|
this.txtProjectCode.Text = _ActionPlanFormation.EPCCode;
|
|
this.txtProjectName.Text = _ActionPlanFormation.ProjectShortName;
|
|
this.txtCreateUser.Text = BLL.Person_PersonsService.GetPersonsNameById(_ActionPlanFormation.CreatUser);
|
|
|
|
if (PHTGL_ApproveService.IsApproveMan(ActionPlanReviewId, this.CurrUser.PersonId))
|
|
{
|
|
BindGrid();
|
|
|
|
}
|
|
else if (this.CurrUser.PersonId == Const.sysglyId || this.CurrUser.PersonId == Const.hfnbdId)
|
|
{
|
|
BindGrid();
|
|
|
|
}
|
|
else if (_ActionPlanFormation.CreatUser == this.CurrUser.PersonId)
|
|
{
|
|
BindGrid();
|
|
}
|
|
|
|
if (pHTGL_Approve != null)
|
|
{
|
|
btnAgree.Enabled = true;
|
|
btnDisgree.Enabled = true;
|
|
}
|
|
|
|
|
|
}
|
|
|
|
}
|
|
#endregion
|
|
|
|
#region 绑定
|
|
/// <summary>
|
|
/// 数据绑定
|
|
/// </summary>
|
|
private void BindGrid()
|
|
{
|
|
string strSql = @" select u.PersonName as ApproveMan,
|
|
App.ApproveDate,
|
|
(CASE App.IsAgree WHEN '1' THEN '不同意'
|
|
WHEN '2' THEN '同意' END) AS IsAgree,
|
|
App.ApproveIdea,
|
|
App.ApproveId,
|
|
App.ApproveType
|
|
from PHTGL_Approve as App"
|
|
+ @" left join Person_Persons AS U ON U.PersonId = App.ApproveMan WHERE 1=1 and App.IsAgree <>0 and app.ContractId= @ContractId order by convert(datetime ,App.ApproveDate) ";
|
|
List<SqlParameter> listStr = new List<SqlParameter>();
|
|
listStr.Add(new SqlParameter("@ContractId", ActionPlanReviewId));
|
|
|
|
SqlParameter[] parameter = listStr.ToArray();
|
|
DataTable tb = SQLHelper.GetDataTableRunText(strSql, parameter);
|
|
//Grid1.RecordCount = tb.Rows.Count;
|
|
//var table = this.GetPagedDataTable(Grid1, tb);
|
|
Grid1.DataSource = tb;
|
|
Grid1.DataBind();
|
|
}
|
|
#endregion
|
|
|
|
#region 附件
|
|
protected void btnAttachUrl_Click(object sender, EventArgs e)
|
|
{
|
|
var Act = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
|
|
|
|
PageContext.RegisterStartupScript(WindowAtt.GetShowReference(String.Format("~/AttachFile/webuploader.aspx?toKeyId={0}&path=FileUpload/ActionPlanAttachUrl&menuId={1}", Act.ActionPlanID, BLL.Const.ActionPlanFormation)));
|
|
}
|
|
#endregion
|
|
|
|
#region 查看
|
|
protected void btnLooK_Click(object sender, EventArgs e)
|
|
{
|
|
|
|
var Act = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
|
|
PageContext.RegisterStartupScript(Window1.GetShowReference(String.Format("ActionPlanFormationEdit.aspx?ActionPlanID={0}", Act.ActionPlanID, "编辑 - ")));
|
|
}
|
|
#endregion
|
|
|
|
#region 同意 保存
|
|
protected void btnAgree_Click(object sender, EventArgs e)
|
|
{
|
|
ApprovemanSave(true);
|
|
OAWebSevice.Pushoa();
|
|
OAWebSevice.DoneRequest(pHTGL_Approve.ApproveId);
|
|
}
|
|
|
|
protected void btnDisgree_Click(object sender, EventArgs e)
|
|
{
|
|
ApprovemanSave(false);
|
|
|
|
OAWebSevice.DoneRequest(pHTGL_Approve.ApproveId);
|
|
OAWebSevice.Pushoa_Creater(pHTGL_Approve.ApproveId);
|
|
}
|
|
|
|
/// <summary>
|
|
/// 审批人员保存
|
|
/// </summary>
|
|
void ApprovemanSave(bool IsAgree)
|
|
{
|
|
pHTGL_Approve.ApproveDate = Funs.GetNewDateTimeOrNow("").ToString();
|
|
pHTGL_Approve.State = 1;
|
|
pHTGL_Approve.IsAgree = IsAgree ? 2 : 1;
|
|
string txtIdea = "";
|
|
if (IsAgree)
|
|
{
|
|
txtIdea = "同意";
|
|
}
|
|
else
|
|
{
|
|
txtIdea = "不同意";
|
|
}
|
|
pHTGL_Approve.ApproveIdea = txtApproveIdea.Text.Trim() == "" ? txtIdea : txtApproveIdea.Text;
|
|
BLL.PHTGL_ApproveService.UpdatePHTGL_Approve(pHTGL_Approve);
|
|
|
|
int thisApproveTypeNumber = ApproveManModels.Find(e => e.Rolename == pHTGL_Approve.ApproveType).Number;
|
|
int nextApproveType = thisApproveTypeNumber + 1;
|
|
|
|
if (IsAgree)
|
|
{
|
|
if (thisApproveTypeNumber < EndApproveType)
|
|
{
|
|
|
|
Model.PHTGL_Approve _Approve = new Model.PHTGL_Approve();
|
|
_Approve.ContractId = pHTGL_Approve.ContractId;
|
|
_Approve.ApproveMan = ApproveManModels.Find(e => e.Number == nextApproveType).userid;
|
|
_Approve.ApproveDate = "";
|
|
_Approve.State = 0;
|
|
_Approve.IsAgree = 0;
|
|
_Approve.ApproveIdea = "";
|
|
_Approve.ApproveType = ApproveManModels.Find(e => e.Number == nextApproveType).Rolename;
|
|
_Approve.IsPushOa = 0;
|
|
_Approve.ApproveForm = PHTGL_ApproveService.ActionPlanReview;
|
|
|
|
var IsExitmodel = PHTGL_ApproveService.GetPHTGL_ApproveByContractIdAndType(_Approve.ContractId, _Approve.ApproveType);
|
|
if (IsExitmodel == null)
|
|
{
|
|
_Approve.ApproveId = SQLHelper.GetNewID(typeof(Model.PHTGL_Approve));
|
|
BLL.PHTGL_ApproveService.AddPHTGL_Approve(_Approve);
|
|
|
|
}
|
|
else
|
|
{
|
|
_Approve.ApproveId = IsExitmodel.ApproveId;
|
|
BLL.PHTGL_ApproveService.UpdatePHTGL_Approve(_Approve);
|
|
|
|
}
|
|
ChangeState(Const.ContractReviewing);
|
|
}
|
|
else
|
|
{
|
|
//var acp = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
|
|
//var act = BLL.PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(acp.ActionPlanID);
|
|
//Model.PHTGL_BidDocumentsReview model = new Model.PHTGL_BidDocumentsReview();
|
|
//model.BidDocumentsReviewId = SQLHelper.GetNewID(typeof(Model.PHTGL_BidDocumentsReview));
|
|
//model.ActionPlanReviewId = ActionPlanReviewId;
|
|
//model.ActionPlanID = acp.ActionPlanID;
|
|
//model.ProjectId = act.ProjectID;
|
|
//model.State = Const.ContractCreating;
|
|
//PHTGL_BidDocumentsReviewService.AddPHTGL_BidDocumentsReview(model);
|
|
ChangeState(Const.ContractReview_Complete);
|
|
}
|
|
}
|
|
else
|
|
{
|
|
ChangeState(Const.ContractReview_Refuse);
|
|
}
|
|
|
|
|
|
ShowNotify("提交成功,流程转入下一节点!", MessageBoxIcon.Success);
|
|
if (!string.IsNullOrEmpty(Request.Params["PHTUrl"]))
|
|
{
|
|
PageContext.RegisterStartupScript(ActiveWindow.GetHideRefreshReference());
|
|
PageContext.RegisterStartupScript("closeActiveTab();");
|
|
|
|
}
|
|
else
|
|
{
|
|
PageContext.RegisterStartupScript(ActiveWindow.GetHideRefreshReference());
|
|
|
|
}
|
|
|
|
|
|
}
|
|
|
|
/// <summary>
|
|
/// 改变审批流状态
|
|
/// </summary>
|
|
/// <param name="state"></param>
|
|
private void ChangeState(int state)
|
|
{
|
|
var _ActionPlanReview = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
|
|
_ActionPlanReview.State = state;
|
|
PHTGL_ActionPlanReviewService.UpdatePHTGL_ActionPlanReview(_ActionPlanReview);
|
|
|
|
//var _ActionPlanFormation= BLL.PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(_ActionPlanReview.ActionPlanID);
|
|
//_ActionPlanFormation.State = state;
|
|
//PHTGL_ActionPlanFormationService.UpdatePHTGL_ActionPlanFormation(_ActionPlanFormation);
|
|
}
|
|
#endregion
|
|
|
|
#region 分页 排序
|
|
/// <summary>
|
|
/// 改变索引事件
|
|
/// </summary>
|
|
/// <param name="sender"></param>
|
|
/// <param name="e"></param>
|
|
protected void Grid1_PageIndexChange(object sender, GridPageEventArgs e)
|
|
{
|
|
BindGrid();
|
|
}
|
|
/// <summary>
|
|
/// 排序
|
|
/// </summary>
|
|
/// <param name="sender"></param>
|
|
/// <param name="e"></param>
|
|
protected void Grid1_Sort(object sender, FineUIPro.GridSortEventArgs e)
|
|
{
|
|
BindGrid();
|
|
}
|
|
#endregion
|
|
|
|
|
|
}
|
|
} |