alter table [dbo].[Check_IncentiveNotice]
|
|
add DutyPersonId nvarchar(50),ProfessionalEngineerId nvarchar(50) null,ConstructionManagerId nvarchar(50) null,
|
|
UnitHeadManId nvarchar(50) null,SignDate DateTime Null,ApproveDate DateTime Null,DutyPersonDate DateTime Null
|
|
|
|
ALTER TABLE [dbo].[Check_IncentiveNotice] WITH CHECK ADD CONSTRAINT [FK_Check_IncentiveNotice_Sys_User2] FOREIGN KEY([DutyPersonId])
|
|
REFERENCES [dbo].[Sys_User] ([UserId])
|
|
GO
|
|
ALTER TABLE [dbo].[Check_IncentiveNotice] CHECK CONSTRAINT [FK_Check_IncentiveNotice_Sys_User2]
|
|
GO
|
|
|
|
ALTER TABLE [dbo].[Check_IncentiveNotice] WITH CHECK ADD CONSTRAINT [FK_Check_IncentiveNotice_Sys_User3] FOREIGN KEY([ProfessionalEngineerId])
|
|
REFERENCES [dbo].[Sys_User] ([UserId])
|
|
GO
|
|
ALTER TABLE [dbo].[Check_IncentiveNotice] CHECK CONSTRAINT [FK_Check_IncentiveNotice_Sys_User3]
|
|
GO
|
|
|
|
ALTER TABLE [dbo].[Check_IncentiveNotice] WITH CHECK ADD CONSTRAINT [FK_Check_IncentiveNotice_Sys_User4] FOREIGN KEY([ConstructionManagerId])
|
|
REFERENCES [dbo].[Sys_User] ([UserId])
|
|
GO
|
|
ALTER TABLE [dbo].[Check_IncentiveNotice] CHECK CONSTRAINT [FK_Check_IncentiveNotice_Sys_User4]
|
|
GO
|
|
|
|
ALTER TABLE [dbo].[Check_IncentiveNotice] WITH CHECK ADD CONSTRAINT [FK_Check_IncentiveNotice_Sys_User5] FOREIGN KEY([UnitHeadManId])
|
|
REFERENCES [dbo].[Sys_User] ([UserId])
|
|
GO
|
|
ALTER TABLE [dbo].[Check_IncentiveNotice] CHECK CONSTRAINT [FK_Check_IncentiveNotice_Sys_User5]
|
|
GO
|
|
|
|
|
|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'施工分包单位责任人ID' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Check_IncentiveNotice', @level2type=N'COLUMN',@level2name=N'DutyPersonId'
|
|
GO
|
|
|
|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'总包专业工程师' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Check_IncentiveNotice', @level2type=N'COLUMN',@level2name=N'ProfessionalEngineerId'
|
|
GO
|
|
|
|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'总包施工经理' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Check_IncentiveNotice', @level2type=N'COLUMN',@level2name=N'ConstructionManagerId'
|
|
GO
|
|
|
|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'相关施工分包单位' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Check_IncentiveNotice', @level2type=N'COLUMN',@level2name=N'UnitHeadManId'
|
|
GO
|
|
|
|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'签发时间' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Check_IncentiveNotice', @level2type=N'COLUMN',@level2name=N'SignDate'
|
|
GO
|
|
|
|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'批准时间' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Check_IncentiveNotice', @level2type=N'COLUMN',@level2name=N'ApproveDate'
|
|
GO
|
|
|
|
EXEC sys.sp_addextendedproperty @name=N'MS_Description', @value=N'回执时间' , @level0type=N'SCHEMA',@level0name=N'dbo', @level1type=N'TABLE',@level1name=N'Check_IncentiveNotice', @level2type=N'COLUMN',@level2name=N'DutyPersonDate'
|
|
GO |