Files
SGGL_SHJ/SGGL/FineUIPro.Web/PHTGL/BiddingManagement/ActionPlanReviewDetail.aspx.cs
T
2024-03-11 23:25:08 +08:00

316 lines
12 KiB
C#

using BLL;
using System;
using System.Collections.Generic;
using System.Data;
using System.Data.SqlClient;
using Model;
namespace FineUIPro.Web.PHTGL.BiddingManagement
{
public partial class ActionPlanReviewDetail : PageBase
{
#region
/// <summary>
/// 合同ID
/// </summary>
public string ActionPlanReviewId
{
get
{
return (string)ViewState["ActionPlanReviewId"];
}
set
{
ViewState["ActionPlanReviewId"] = value;
}
}
/// <summary>
/// 最末的审批节点
/// </summary>
public int EndApproveType
{
get
{
return (int)ViewState["EndApproveType"];
}
set
{
ViewState["EndApproveType"] = value;
}
}
/// <summary>
/// 审批人字典
/// </summary>
public Dictionary<int, string> Dic_ApproveMan
{
get
{
return (Dictionary<int, string>)ViewState["Dic_ApproveMan"];
}
set
{
ViewState["Dic_ApproveMan"] = value;
}
}
public Model.PHTGL_Approve pHTGL_Approve
{
get
{
return (Model.PHTGL_Approve)Session["pHTGL_Approve"];
}
set
{
Session["pHTGL_Approve"] = value;
}
}
public List<ApproveManModel> ApproveManModels
{
get
{
return (List<ApproveManModel>)Session["ApproveManModels"];
}
set
{
Session["ApproveManModels"] = value;
}
}
#endregion
#region
protected void Page_Load(object sender, EventArgs e)
{
if (!IsPostBack)
{
ActionPlanReviewId = Request.Params["ActionPlanReviewId"];
//获取招标实施计划基本信息
var _ActionPlanReview = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
var _ActionPlanFormation = BLL.PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(_ActionPlanReview.ActionPlanID);
//获取审批人字典
ApproveManModels = PHTGL_ActionPlanReviewService.GetApproveManModels(_ActionPlanFormation.ProjectID, ActionPlanReviewId);
EndApproveType = ApproveManModels.Count;
//获取当前登录人审批信息
pHTGL_Approve = BLL.PHTGL_ApproveService.GetPHTGL_ApproveByUserId(ActionPlanReviewId, this.CurrUser.PersonId);
this.txtProjectCode.Text = _ActionPlanFormation.EPCCode;
this.txtProjectName.Text = _ActionPlanFormation.ProjectShortName;
this.txtCreateUser.Text = BLL.Person_PersonsService.GetPersonsNameById(_ActionPlanFormation.CreatUser);
if (PHTGL_ApproveService.IsApproveMan(ActionPlanReviewId, this.CurrUser.PersonId))
{
BindGrid();
}
else if (this.CurrUser.PersonId == Const.sysglyId || this.CurrUser.PersonId == Const.hfnbdId)
{
BindGrid();
}
else if (_ActionPlanFormation.CreatUser == this.CurrUser.PersonId)
{
BindGrid();
}
if (pHTGL_Approve != null)
{
btnAgree.Enabled = true;
btnDisgree.Enabled = true;
}
}
}
#endregion
#region
/// <summary>
/// 数据绑定
/// </summary>
private void BindGrid()
{
string strSql = @" select u.PersonName as ApproveMan,
App.ApproveDate,
(CASE App.IsAgree WHEN '1' THEN '不同意'
WHEN '2' THEN '同意' END) AS IsAgree,
App.ApproveIdea,
App.ApproveId,
App.ApproveType
from PHTGL_Approve as App"
+ @" left join Person_Persons AS U ON U.PersonId = App.ApproveMan WHERE 1=1 and App.IsAgree <>0 and app.ContractId= @ContractId order by convert(datetime ,App.ApproveDate) ";
List<SqlParameter> listStr = new List<SqlParameter>();
listStr.Add(new SqlParameter("@ContractId", ActionPlanReviewId));
SqlParameter[] parameter = listStr.ToArray();
DataTable tb = SQLHelper.GetDataTableRunText(strSql, parameter);
//Grid1.RecordCount = tb.Rows.Count;
//var table = this.GetPagedDataTable(Grid1, tb);
Grid1.DataSource = tb;
Grid1.DataBind();
}
#endregion
#region
protected void btnAttachUrl_Click(object sender, EventArgs e)
{
var Act = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
PageContext.RegisterStartupScript(WindowAtt.GetShowReference(String.Format("~/AttachFile/webuploader.aspx?toKeyId={0}&path=FileUpload/ActionPlanAttachUrl&menuId={1}", Act.ActionPlanID, BLL.Const.ActionPlanFormation)));
}
#endregion
#region
protected void btnLooK_Click(object sender, EventArgs e)
{
var Act = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
PageContext.RegisterStartupScript(Window1.GetShowReference(String.Format("ActionPlanFormationEdit.aspx?ActionPlanID={0}", Act.ActionPlanID, "编辑 - ")));
}
#endregion
#region
protected void btnAgree_Click(object sender, EventArgs e)
{
ApprovemanSave(true);
OAWebSevice.Pushoa();
OAWebSevice.DoneRequest(pHTGL_Approve.ApproveId);
}
protected void btnDisgree_Click(object sender, EventArgs e)
{
ApprovemanSave(false);
OAWebSevice.DoneRequest(pHTGL_Approve.ApproveId);
OAWebSevice.Pushoa_Creater(pHTGL_Approve.ApproveId);
}
/// <summary>
/// 审批人员保存
/// </summary>
void ApprovemanSave(bool IsAgree)
{
pHTGL_Approve.ApproveDate = Funs.GetNewDateTimeOrNow("").ToString();
pHTGL_Approve.State = 1;
pHTGL_Approve.IsAgree = IsAgree ? 2 : 1;
string txtIdea = "";
if (IsAgree)
{
txtIdea = "同意";
}
else
{
txtIdea = "不同意";
}
pHTGL_Approve.ApproveIdea = txtApproveIdea.Text.Trim() == "" ? txtIdea : txtApproveIdea.Text;
BLL.PHTGL_ApproveService.UpdatePHTGL_Approve(pHTGL_Approve);
int thisApproveTypeNumber = ApproveManModels.Find(e => e.Rolename == pHTGL_Approve.ApproveType).Number;
int nextApproveType = thisApproveTypeNumber + 1;
if (IsAgree)
{
if (thisApproveTypeNumber < EndApproveType)
{
Model.PHTGL_Approve _Approve = new Model.PHTGL_Approve();
_Approve.ContractId = pHTGL_Approve.ContractId;
_Approve.ApproveMan = ApproveManModels.Find(e => e.Number == nextApproveType).userid;
_Approve.ApproveDate = "";
_Approve.State = 0;
_Approve.IsAgree = 0;
_Approve.ApproveIdea = "";
_Approve.ApproveType = ApproveManModels.Find(e => e.Number == nextApproveType).Rolename;
_Approve.IsPushOa = 0;
_Approve.ApproveForm = PHTGL_ApproveService.ActionPlanReview;
var IsExitmodel = PHTGL_ApproveService.GetPHTGL_ApproveByContractIdAndType(_Approve.ContractId, _Approve.ApproveType);
if (IsExitmodel == null)
{
_Approve.ApproveId = SQLHelper.GetNewID(typeof(Model.PHTGL_Approve));
BLL.PHTGL_ApproveService.AddPHTGL_Approve(_Approve);
}
else
{
_Approve.ApproveId = IsExitmodel.ApproveId;
BLL.PHTGL_ApproveService.UpdatePHTGL_Approve(_Approve);
}
ChangeState(Const.ContractReviewing);
}
else
{
//var acp = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
//var act = BLL.PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(acp.ActionPlanID);
//Model.PHTGL_BidDocumentsReview model = new Model.PHTGL_BidDocumentsReview();
//model.BidDocumentsReviewId = SQLHelper.GetNewID(typeof(Model.PHTGL_BidDocumentsReview));
//model.ActionPlanReviewId = ActionPlanReviewId;
//model.ActionPlanID = acp.ActionPlanID;
//model.ProjectId = act.ProjectID;
//model.State = Const.ContractCreating;
//PHTGL_BidDocumentsReviewService.AddPHTGL_BidDocumentsReview(model);
ChangeState(Const.ContractReview_Complete);
}
}
else
{
ChangeState(Const.ContractReview_Refuse);
}
ShowNotify("提交成功,流程转入下一节点!", MessageBoxIcon.Success);
if (!string.IsNullOrEmpty(Request.Params["PHTUrl"]))
{
PageContext.RegisterStartupScript(ActiveWindow.GetHideRefreshReference());
PageContext.RegisterStartupScript("closeActiveTab();");
}
else
{
PageContext.RegisterStartupScript(ActiveWindow.GetHideRefreshReference());
}
}
/// <summary>
/// 改变审批流状态
/// </summary>
/// <param name="state"></param>
private void ChangeState(int state)
{
var _ActionPlanReview = BLL.PHTGL_ActionPlanReviewService.GetPHTGL_ActionPlanReviewById(ActionPlanReviewId);
_ActionPlanReview.State = state;
PHTGL_ActionPlanReviewService.UpdatePHTGL_ActionPlanReview(_ActionPlanReview);
//var _ActionPlanFormation= BLL.PHTGL_ActionPlanFormationService.GetPHTGL_ActionPlanFormationById(_ActionPlanReview.ActionPlanID);
//_ActionPlanFormation.State = state;
//PHTGL_ActionPlanFormationService.UpdatePHTGL_ActionPlanFormation(_ActionPlanFormation);
}
#endregion
#region
/// <summary>
/// 改变索引事件
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Grid1_PageIndexChange(object sender, GridPageEventArgs e)
{
BindGrid();
}
/// <summary>
/// 排序
/// </summary>
/// <param name="sender"></param>
/// <param name="e"></param>
protected void Grid1_Sort(object sender, FineUIPro.GridSortEventArgs e)
{
BindGrid();
}
#endregion
}
}