using System;
using System.Collections.Generic;
using System.Linq;
using System.Data;
using System.Data.SqlClient;
using System.Web.UI.DataVisualization.Charting;
using System.Drawing;
using BLL;

namespace FineUIPro.Web.common
{
    public partial class MainSupervision : PageBase
    {
        protected void Page_Load(object sender, EventArgs e)
        {
            if (!IsPostBack)
            {
                ShowChart();
                BindPointNoTrust();
                BindTrustNoCheck();
                BindCheckNoAudit();
                BindPointWarn();
            }
        }

        private void BindPointWarn()
        {
            string strSql = @"SELECT ins.InstallationCode,t.PointBatchCode,welder.WelderCode,t.WeldingNum,t.LastWeldingDate
                                FROM
                                  (SELECT pb.ProjectId,pb.InstallationId,pb.UnitId,pb.PointBatchCode,jot.CoverWelderId,rate.DetectionRateValue,
                                          COUNT(pbItem.PointBatchItemId) AS WeldingNum,MIN(daily.WeldingDate) AS LastWeldingDate
                                     FROM dbo.Batch_PointBatchItem AS pbItem
                                     LEFT JOIN Batch_PointBatch AS pb ON pb.PointBatchId=pbItem.PointBatchId
                                     LEFT JOIN Pipeline_WeldJoint AS jot ON jot.WeldJointId=pbItem.WeldJointId
                                     LEFT JOIN dbo.Pipeline_WeldingDaily daily ON daily.WeldingDailyId = jot.WeldingDailyId
                                     LEFT JOIN dbo.Base_DetectionRate rate ON rate.DetectionRateId = pb.DetectionRateId
                                     WHERE pbItem.IsCompletedPoint=0 AND jot.WeldingDailyId IS NOT NULL
                                     GROUP BY pb.ProjectId,pb.InstallationId,pb.UnitId,pb.PointBatchCode,rate.DetectionRateValue,jot.CoverWelderId
                                    )t
                                 LEFT JOIN dbo.Welder_Welder welder ON welder.WelderId = t.CoverWelderId
                                 LEFT JOIN dbo.Project_Installation ins ON ins.InstallationId = t.InstallationId
                                 WHERE t.ProjectId=@ProjectId ";

            List<SqlParameter> listStr = new List<SqlParameter>();
            if (!string.IsNullOrEmpty(this.CurrUser.LoginProjectId))
            {
                listStr.Add(new SqlParameter("@ProjectId", this.CurrUser.LoginProjectId));
            }

            var q = from x in BLL.Funs.DB.Sys_Set where x.ProjectId == this.CurrUser.LoginProjectId && x.SetId == "6" select x;
            if (q.Count() > 0 && !string.IsNullOrEmpty(q.First().SetValue))
            {
                strSql += " AND t.WeldingNum>=(@WarnPontRate/t.DetectionRateValue)";
                listStr.Add(new SqlParameter("@WarnPontRate", Convert.ToInt32(q.First().SetValue)));
            }
            else
            {
                strSql += " AND t.WeldingNum>='5'";
            }

            var d = from x in BLL.Funs.DB.Sys_Set where x.ProjectId == this.CurrUser.LoginProjectId && x.SetId == "5" select x;
            if (d.Count() > 0 && !string.IsNullOrEmpty(d.First().SetValue))
            {
                strSql += " AND DATEDIFF(DAY,t.LastWeldingDate,GETDATE())>@WarnPointDay";
                listStr.Add(new SqlParameter("@WarnPointDay", Convert.ToInt32(d.First().SetValue)));
            }
            else
            {
                strSql += " AND DATEDIFF(DAY,t.LastWeldingDate,GETDATE())>'3'";
            }

            SqlParameter[] parameter = listStr.ToArray();
            DataTable dt = SQLHelper.GetDataTableRunText(strSql, parameter);
            gvPointWarn.DataSource = dt;
            gvPointWarn.DataBind();
        }

        private void BindPointNoTrust()
        {
            string strSql = @" SELECT  (u.UnitName+':'+ Convert(varchar(6),COUNT(batchItem.PointBatchItemId))) AS  PointNoTrust  
                                 FROM dbo.Batch_PointBatchItem batchItem
                                 LEFT JOIN dbo.Pipeline_WeldJoint jot ON jot.WeldJointId = batchItem.WeldJointId
                                 LEFT JOIN dbo.Batch_BatchTrustItem trustItem ON trustItem.PointBatchItemId = batchItem.PointBatchItemId
                                 LEFT JOIN dbo.Pipeline_Pipeline pipe ON pipe.PipelineId = jot.PipelineId
								 LEFT JOIN Base_Unit u on u.UnitId=pipe.UnitId
                                WHERE batchItem.PointState IS NOT NULL AND trustItem.TrustBatchItemId IS NULL 
                                      AND pipe.ProjectId=@ProjectId
								group by pipe.ProjectId ,u.UnitName";

            if (!string.IsNullOrEmpty(this.CurrUser.LoginProjectId))
            {
                SqlParameter[] parameter = new SqlParameter[]
                     {
                        new SqlParameter("@ProjectId", this.CurrUser.LoginProjectId)
                     };
                DataTable dt = SQLHelper.GetDataTableRunText(strSql, parameter);
                gvPointNoTrust.DataSource = dt;
                gvPointNoTrust.DataBind();
            }
        }

        private void BindTrustNoCheck()
        {
            string strSql = @"SELECT  (u.UnitName+':'+Convert(varchar(6),COUNT(trustItem.TrustBatchItemId))) AS  TrustNoCheck
                                 FROM Batch_BatchTrustItem trustItem
                                 LEFT JOIN dbo.Batch_BatchTrust trust ON trust.TrustBatchId = trustItem.TrustBatchId
                                 LEFT JOIN dbo.Base_DetectionType ndttype ON ndttype.DetectionTypeId = trust.DetectionTypeId
                                 LEFT JOIN dbo.Pipeline_WeldJoint jot ON jot.WeldJointId = trustItem.WeldJointId
                                 LEFT JOIN dbo.Batch_NDEItem ndtItem ON ndtItem.TrustBatchItemId = trustItem.TrustBatchItemId
                                 LEFT JOIN dbo.Pipeline_Pipeline pipe ON pipe.PipelineId = jot.PipelineId
								 LEFT JOIN Base_Unit u on u.UnitId=pipe.UnitId
                                 WHERE ndtItem.NDEItemID IS NULL  AND IsCancelTrust is null AND pipe.ProjectId=@ProjectId
								 GROUP BY pipe.ProjectId, u.UnitName";

            if (!string.IsNullOrEmpty(this.CurrUser.LoginProjectId))
            {
                SqlParameter[] parameter = new SqlParameter[]
                     {
                        new SqlParameter("@ProjectId", this.CurrUser.LoginProjectId)
                     };
                DataTable dt = SQLHelper.GetDataTableRunText(strSql, parameter);
                gvTrustNoCheck.DataSource = dt;
                gvTrustNoCheck.DataBind();
            }
        }

        private void BindCheckNoAudit()
        {
         //   string strSql = @" SELECT (u.UnitName+':'+Convert(varchar(6),COUNT(ndtItem.NDEItemID))) AS  CheckNoAudit
         //                        FROM dbo.Batch_NDEItem ndtItem
         //                        LEFT JOIN dbo.Batch_NDE ndt ON ndt.NDEID = ndtItem.NDEID
         //                        LEFT JOIN dbo.Batch_BatchTrustItem trust ON trust.TrustBatchItemId = ndtItem.TrustBatchItemId
         //                        LEFT JOIN dbo.Pipeline_WeldJoint jot ON jot.WeldJointId = trust.WeldJointId  
         //                        LEFT JOIN dbo.Pipeline_Pipeline pipe ON pipe.PipelineId = jot.PipelineId
								 //LEFT JOIN Base_Unit u on u.UnitId=pipe.UnitId
         //                       WHERE ndtItem.SubmitDate IS NULL AND ndt.ProjectId=@ProjectId
							  //  GROUP BY pipe.ProjectId, u.UnitName";

         //   if (!string.IsNullOrEmpty(this.CurrUser.LoginProjectId))
         //   {
         //       SqlParameter[] parameter = new SqlParameter[]
         //            {
         //               new SqlParameter("@ProjectId", this.CurrUser.LoginProjectId)
         //            };
         //       DataTable dt = SQLHelper.GetDataTableRunText(strSql, parameter);
         //       gvCheckNoAudit.DataSource = dt;
         //       gvCheckNoAudit.DataBind();
         //   }
        }

        private void ShowChart()
        {
            string strSql1 = @"SELECT v.totalDin AS '预估',(v.totalDin-ISNULL(v1.LastDin,0)) AS '完成', 
                                      ISNULL(v1.LastDin,0) AS '剩余',ISNULL(v2.LastWeekDin,0) AS '近一周'
                                FROM
                                   (SELECT ProjectId, ISNULL(SUM(ISNULL(Size,0)),0) AS totalDin 
                                      FROM dbo.Pipeline_WeldJoint GROUP BY ProjectId) v
                                    LEFT JOIN
                                   (SELECT ProjectId, ISNULL(SUM(ISNULL(Size,0)),0) AS LastDin 
                                    FROM dbo.Pipeline_WeldJoint 
                                    WHERE WeldingDailyId IS NULL GROUP BY ProjectId) v1 ON v1.ProjectId = v.ProjectId
                                   
                                    LEFT JOIN
                                   (SELECT jot.ProjectId, ISNULL(SUM(ISNULL(jot.Size,0)),0) AS LastWeekDin 
                                    FROM dbo.Pipeline_WeldJoint jot
                                    
                                    LEFT JOIN dbo.Pipeline_WeldingDaily report ON report.WeldingDailyId = jot.WeldingDailyId
                                    WHERE jot.WeldingDailyId IS NOT NULL AND report.WeldingDate<=GETDATE() AND report.WeldingDate>DATEADD(ww,-1,GETDATE())
                                    GROUP BY jot.ProjectId) v2 ON v2.ProjectId = v.ProjectId
                                WHERE v.ProjectId=@ProjectId1";

            string strSql2 = @"SELECT ISNULL(v1.BatchTrustNum,0) AS '委托数',ISNULL(v2.NdtCheckNum,0) AS '拍片焊口',
                                     (ISNULL(v1.BatchTrustNum,0)-ISNULL(v2.NdtCheckNum,0)) AS '积压焊口' ,
                                     ISNULL(v3.LastWeekCheckNum,0) AS '近一周检测'
                                FROM 
                                   (SELECT trust.ProjectId, COUNT(d.TrustBatchItemId) AS BatchTrustNum 
                                    FROM dbo.Batch_BatchTrustItem  d
                                    LEFT JOIN dbo.Batch_BatchTrust trust ON  trust.TrustBatchId = d.TrustBatchId
                                    LEFT JOIN dbo.Base_DetectionType ndt ON ndt.DetectionTypeId = trust.DetectionTypeId
                                    WHERE ndt.SysType='射线检测' GROUP BY trust.ProjectId) v1
                               LEFT JOIN 
                                   (SELECT ndt.ProjectId,COUNT(ndtItme.NDEItemID) AS NdtCheckNum 
                                      FROM dbo.Batch_NDEItem ndtItme 
                                      LEFT JOIN dbo.Batch_NDE ndt ON ndt.NDEID = ndtItme.NDEID
                                      LEFT JOIN dbo.Base_DetectionType ndtType ON ndtType.DetectionTypeId = ndtItme.DetectionTypeId
                                    WHERE ndtType.SysType ='射线检测' AND SubmitDate IS NOT NULL
                                    GROUP BY ndt.ProjectId ) v2 ON v2.ProjectId = v1.ProjectId   
                              LEFT JOIN 
                                   (SELECT ndt.ProjectId,COUNT(ndtItme.NDEItemID) AS LastWeekCheckNum 
                                      FROM dbo.Batch_NDEItem ndtItme 
                                      LEFT JOIN dbo.Batch_NDE ndt ON ndt.NDEID = ndtItme.NDEID
                                      LEFT JOIN dbo.Base_DetectionType ndtType ON ndtType.DetectionTypeId = ndtItme.DetectionTypeId
                                     WHERE ndtType.SysType ='射线检测' AND SubmitDate IS NOT NULL
                                           AND ndtItme.SubmitDate<=GETDATE() AND ndtItme.SubmitDate>DATEADD(ww,-1,GETDATE())
                                          GROUP BY ndt.ProjectId ) v3 ON v3.ProjectId = v1.ProjectId   
                             WHERE v1.ProjectId=@ProjectId2 AND ISNULL(v1.BatchTrustNum,0)>0  ";

            if (!string.IsNullOrEmpty(this.CurrUser.LoginProjectId))
            {
                SqlParameter[] parameter1 = new SqlParameter[]
                     {
                        new SqlParameter("@ProjectId1", this.CurrUser.LoginProjectId)
                     };
                DataTable dt1 = SQLHelper.GetDataTableRunText(strSql1, parameter1);

                SqlParameter[] parameter2 = new SqlParameter[]
                    {
                        new SqlParameter("@ProjectId2", this.CurrUser.LoginProjectId)
                    };
                DataTable dt2 = SQLHelper.GetDataTableRunText(strSql2, parameter2);

                if (dt1.Rows.Count > 0)
                {
                    CreateChart(dt1, Chart1);
                }
                if (dt2.Rows.Count > 0)
                {
                    CreateChart(dt2, Chart2);
                }
            }
        }


        /// <summary>
        /// 创建Chart图形
        /// </summary>
        /// <param name="dt">数据表</param>
        /// <param name="chart1">图形</param>
        private void CreateChart(DataTable dt, Chart chart1)
        {
            chart1.BackColor = Color.WhiteSmoke;
            chart1.ImageLocation = "~/Images/ChartPic_#SEQ(300,3)";
            chart1.BorderlineDashStyle = ChartDashStyle.Solid;
            chart1.Palette = ChartColorPalette.BrightPastel;
            chart1.BackSecondaryColor = Color.White;
            chart1.BackGradientStyle = GradientStyle.TopBottom;
            chart1.BorderWidth = 2;
            chart1.BorderColor = Color.FromArgb(26, 59, 105);
            chart1.ImageType = ChartImageType.Png;

            ChartArea chartArea = new ChartArea();
            chartArea.Name = "焊接工作量";
            chartArea.BackColor = Color.Transparent;
            chartArea.AxisX.IsLabelAutoFit = false;
            chartArea.AxisY.IsLabelAutoFit = false;
            chartArea.AxisX.LabelStyle.Font = new Font("Verdana,Arial,Helvetica,sans-serif", 8F, FontStyle.Regular);
            chartArea.AxisY.LabelStyle.Font = new Font("Verdana,Arial,Helvetica,sans-serif", 8F, FontStyle.Regular);
            chartArea.AxisY.LineColor = Color.FromArgb(64, 64, 64, 64);
            chartArea.AxisX.LineColor = Color.FromArgb(64, 64, 64, 64);
            chartArea.AxisY.MajorGrid.LineColor = Color.FromArgb(64, 64, 64, 64);
            chartArea.AxisX.MajorGrid.LineColor = Color.FromArgb(64, 64, 64, 64);
            chartArea.AxisX.Interval = 1;
            chartArea.Area3DStyle.Enable3D = true;
            chart1.ChartAreas.Add(chartArea);

            chart1.Series.Add("焊接工作量");
            chart1.Series["焊接工作量"].ChartType = ChartControlService.GetChartType("Column");
            chart1.Series["焊接工作量"].Name = "焊接工作量";
            chart1.Series["焊接工作量"].IsValueShownAsLabel = false;
            chart1.Series["焊接工作量"].BorderWidth = 2;
            chart1.Series["焊接工作量"]["DrawingStyle"] = "Cylinder";

            for (int i = 0; i < dt.Columns.Count; i++)
            {
                
                chart1.Series["焊接工作量"].Points.AddXY(dt.Columns[i].ColumnName, dt.Rows[0][i].ToString());
                chart1.Series["焊接工作量"].Points[i].Color = GetColor(i);
                //chart1.Series["焊接工作量"].Points[i].Url = "~/WeldingProcess/WeldingReport/WeldSummary.aspx";
                chart1.Series["焊接工作量"].Points[i].ToolTip = "#VALX:#VALY";
            }
        }

        private Color GetColor(int i)
        {
            Color c = Color.Blue;
            if (i == 1)
            {
                c = Color.Yellow;
            }
            if (i == 2)
            {
                c = Color.Red;
            }
            if (i == 3)
            {
                c = Color.Green;
            }
            return c;
        }
    }
}