ALTER TABLE dbo.Pipeline_WeldJoint ADD PageNum NVARCHAR(10) ALTER TABLE dbo.Pipeline_WeldJoint ADD ANSISCH NVARCHAR(10) GO ALTER TABLE dbo.Base_DNCompare ALTER COLUMN PipeSize DECIMAL(9,2) NULL ALTER TABLE dbo.Base_DNCompare ADD DN INT NULL ALTER TABLE dbo.Base_DNCompare ADD SCH5 DECIMAL(9,2) NULL ALTER TABLE dbo.Base_DNCompare ADD SCH5S DECIMAL(9,2) NULL ALTER TABLE dbo.Base_DNCompare ADD SCH10S DECIMAL(9,2) NULL ALTER TABLE dbo.Base_DNCompare ADD SCH40S DECIMAL(9,2) NULL ALTER TABLE dbo.Base_DNCompare ADD SCH80S DECIMAL(9,2) NULL GO ALTER PROC [dbo].[sp_rpt_JointComprehensive] @projectId NVARCHAR(50), @workAreaId NVARCHAR(50), @pipelineIds NVARCHAR(MAX) = NULL AS /**********焊口综合信息**********/ SELECT weldJoint.WeldJointId, weldJoint.ProjectId, WorkArea.WorkAreaId, WorkArea.WorkAreaCode, weldJoint.SystemNumber, weldJoint.TestPackageNo, pipeline.SingleNumber, pipeline.PipelineCode, weldJoint.PipeSegment,--所属管段 (CASE WHEN weldJoint.JointAttribute='固定F' THEN 'F'+weldJoint.WeldJointCode ELSE 'S'+weldJoint.WeldJointCode END) AS WeldJointCode, weldType.WeldTypeCode, weldJoint.JointAttribute, weldJoint.Dia, weldJoint.Thickness,--壁厚 weldJoint.HeartNo1, weldJoint.HeartNo2, com1.ComponentsName AS PipeAssembly1, com2.ComponentsName AS PipeAssembly2, material.MaterialCode, cw.WelderCode AS CoverWelderCode, fw.WelderCode AS BackingWelderCode, WeldMethod.WeldingMethodName, medium.MediumName, weldingDaily.WeldingDate, weldingDaily.WeldingDailyCode, trust.TrustBatchCode, --TrustBatchCode.DetectionRateCode, --TrustBatchCode.AcceptLevel, (CASE WHEN weldJoint.IsHotProess=1 THEN '是' ELSE '否' END) AS IsHotProess, null as TrustBatchCode, null as DetectionRateCode, null as AcceptLevel, nde.NDEDate AS CHT_CHECKDATE, ndeItem.NDEReportNo, CAST(ISNULL(weldJoint.Size,0) AS DECIMAL(19,2)) AS JOT_Size, WeldMaterialMat.ConsumablesCode AS WMT_MatCode, WeldMaterialMat.ConsumablesName AS WMT_Matname, WeldMaterialSilk.ConsumablesCode AS hsCode, WeldMaterialSilk.ConsumablesName AS hsname, weldJoint.Specification, wps.WPQCode,ndttype.DetectionTypeCode,NULL AS HotReportCode, (CASE WHEN (PointBatchItem.PointState='1' OR PointBatchItem.PointState='2') then '是' ELSE '否' END) AS if_dk FROM Pipeline_WeldJoint AS weldJoint LEFT JOIN Pipeline_Pipeline AS pipeline ON pipeline.PipelineId = weldJoint.PipelineId LEFT JOIN Project_WorkArea AS WorkArea ON WorkArea.WorkAreaId = pipeline.WorkAreaId LEFT JOIN Base_Material AS material ON material.MaterialId = weldJoint.Material1Id LEFT JOIN Base_WeldingMethod AS WeldMethod ON WeldMethod.WeldingMethodId = weldJoint.WeldingMethodId LEFT JOIN dbo.Base_WeldType weldType ON weldType.WeldTypeId = weldJoint.WeldTypeId LEFT JOIN Base_Medium AS medium ON medium.MediumId = pipeline.MediumId LEFT JOIN Base_Components com1 ON com1.ComponentsId=weldJoint.PipeAssembly1Id LEFT JOIN Base_Components com2 ON com2.ComponentsId=weldJoint.PipeAssembly2Id LEFT JOIN Pipeline_WeldingDaily AS weldingDaily ON weldingDaily.WeldingDailyId = weldJoint.WeldingDailyId LEFT JOIN dbo.WPQ_WPQList wps ON wps.WPQId = weldJoint.WPQId left join Welder_Welder AS fw on weldJoint.BackingWelderId = fw.WelderId left join Welder_Welder AS cw on weldJoint.CoverWelderId = cw.WelderId LEFT JOIN Base_Consumables AS WeldMaterialMat ON WeldMaterialMat.ConsumablesId =weldJoint.WeldMatId LEFT JOIN Base_Consumables AS WeldMaterialSilk ON WeldMaterialSilk.ConsumablesId =weldJoint.WeldSilkId LEFT JOIN Batch_PointBatchItem AS PointBatchItem ON PointBatchItem.WeldJointId =weldJoint.WeldJointId LEFT JOIN dbo.Batch_PointBatch point ON point.PointBatchId = PointBatchItem.PointBatchId LEFT JOIN dbo.Base_DetectionType ndttype ON ndttype.DetectionTypeId = point.DetectionTypeId LEFT JOIN dbo.Batch_BatchTrustItem trustItem ON trustItem.PointBatchItemId = PointBatchItem.PointBatchItemId LEFT JOIN dbo.Batch_BatchTrust trust ON trust.TrustBatchId = trustItem.TrustBatchId LEFT JOIN dbo.Batch_NDEItem ndeItem ON ndeItem.TrustBatchItemId = trustItem.TrustBatchItemId LEFT JOIN dbo.Batch_NDE nde ON nde.NDEID = ndeItem.NDEID --LEFT JOIN (SELECT PointBatchItem.WeldJointId,PointBatchItem.AcceptLevel, TrustBatchCode,rate.DetectionRateCode FROM Batch_BatchTrustItem AS TrustBatchItem -- LEFT JOIN Batch_BatchTrust AS TrustBatch ON TrustBatchItem.TrustBatchId = TrustBatch.TrustBatchId -- LEFT JOIN Batch_PointBatchItem AS PointBatchItem ON TrustBatchItem.PointBatchItemId =PointBatchItem.PointBatchItemId -- LEFT JOIN Batch_PointBatch AS point ON point.PointBatchId =PointBatchItem.PointBatchId -- LEFT JOIN Base_DetectionRate rate ON rate.DetectionRateId =point.DetectionRateId) -- AS TrustBatchCode ON TrustBatchCode.WeldJointId = weldJoint.WeldJointId --LEFT JOIN (SELECT PointBatchItem.WeldJointId,NDEDate -- FROM Batch_NDEItem AS NDEItem -- LEFT JOIN Batch_BatchTrustItem AS TrustBatchItem ON NDEItem.TrustBatchItemId = TrustBatchItem.TrustBatchItemId -- LEFT JOIN Batch_PointBatchItem AS PointBatchItem ON PointBatchItem.PointBatchItemId = TrustBatchItem.PointBatchItemId -- LEFT JOIN Batch_NDE AS Checks ON NDEItem.NDEID = Checks.NDEID) -- AS CheckDate ON CheckDate.WeldJointId = weldJoint.WeldJointId WHERE weldJoint.ProjectId=@projectId AND(pipeline.WorkAreaId=@workAreaId OR @workAreaId IS NULL) AND (CHARINDEX(weldJoint.PipelineId,@pipelineIds)>0 or @pipelineIds IS NULl) --AND(pipeline.PipelineCode=@pipelineCode OR @pipelineCode IS NULl) GO ALTER VIEW [dbo].[View_Pipeline_WeldJoint] AS /************焊口信息视图*****************/ SELECT WeldJoint.WeldJointId, WeldJoint.ProjectId, WeldJoint.PipelineId, WeldJoint.WeldJointCode, dbo.Fun_GetParseInt(WeldJoint.WeldJointCode) AS ConvertWeldJoint, WeldJoint.WeldTypeId, WeldJoint.Material1Id, WeldJoint.Material2Id, WeldJoint.ANSISCH, WeldJoint.Thickness, WeldJoint.Dia, WeldJoint.Size, WeldJoint.JointAttribute, WeldJoint.JointArea, WeldJoint.WeldingMethodId, WeldJoint.IsHotProess, WeldJoint.WeldingLocationId, WeldJoint.WeldMatId, WeldJoint.WeldSilkId, WeldJoint.GrooveTypeId, WeldJoint.PipeSegment, WeldJoint.PipeAssembly1Id, WeldJoint.PipeAssembly2Id, WeldJoint.PipeAssemblyCount, WeldJoint.HeartNo1, WeldJoint.HeartNo2, WeldJoint.LastTemp, WeldJoint.CellTemp, WeldJoint.PrepareTemp, WeldJoint.Electricity, WeldJoint.SystemNumber, WeldJoint.Remark, WeldJoint.DoneDin, WeldJoint.Voltage, WeldJoint.TestPackageNo, WeldJoint.WeldingDailyCode, WeldJoint.WeldingDailyId, WeldJoint.BackingWelderId, WeldJoint.CoverWelderId, WeldJoint.PipingClassId, WeldJoint.Specification, WeldJoint.CancelResult, Project.ProjectCode, Project.ProjectName, Pipeline.PipelineCode, Pipeline.InstallationId, Pipeline.UnitId, Pipeline.SingleNumber, Pipeline.WorkAreaId, WeldType.WeldTypeCode, Material1.MaterialCode AS Material1Code, Material2.MaterialCode AS Material2Code, WeldingMethod.WeldingMethodCode, WeldingLocation.WeldingLocationCode, WeldMat.ConsumablesCode AS WeldMatCode, WeldSilk.ConsumablesCode AS WeldSilkCode, GrooveType.GrooveTypeCode, CASE WHEN WeldJoint.WeldingDailyId IS NULL THEN '否' ELSE '是' END AS Is_hjName, CASE WHEN WeldJoint.IsHotProess=1 THEN '是' ELSE '否' END AS IsHotProessStr, Components1.ComponentsCode AS ComponentsCode1, Components2.ComponentsCode AS ComponentsCode2, BackingWelder.WelderCode AS BackingWelderCode, BackingWelder.WelderName AS BackingWelderName, CoverWelder.WelderCode AS CoverWelderCode, CoverWelder.WelderName AS CoverWelderName, (CASE WHEN CoverWelder.WelderCode IS NOT NULL AND BackingWelder.WelderCode IS NOT NULL THEN CoverWelder.WelderCode + '/' + BackingWelder.WelderCode ELSE (ISNULL(CoverWelder.WelderCode,'') + ISNULL(BackingWelder.WelderCode,'')) END) AS WelderCode, --焊工 (CASE WHEN Material1.MaterialCode IS NOT NULL AND Material2.MaterialCode IS NOT NULL THEN Material1.MaterialCode + '/' + Material2.MaterialCode ELSE (ISNULL(Material1.MaterialCode,'') + ISNULL(Material2.MaterialCode,'')) END) AS MaterialCode, --材质 pipingClass.PipingClassCode, CONVERT(VARCHAR(100), WeldingDaily.WeldingDate, 23) AS WeldingDate, WeldJoint.IsCancel, WeldJoint.IsGoldJoint, WeldJoint.WPQId,wps.WPQCode, WeldJoint.DetectionType, WeldJoint.PageNum FROM Pipeline_WeldJoint AS WeldJoint LEFT JOIN Base_Project AS Project ON Project.ProjectId=WeldJoint.ProjectId LEFT JOIN Pipeline_Pipeline AS Pipeline ON Pipeline.PipelineId = WeldJoint.PipelineId LEFT JOIN Base_WeldType AS WeldType ON WeldType.WeldTypeId=WeldJoint.WeldTypeId LEFT JOIN Base_Material AS Material1 ON Material1.MaterialId = WeldJoint.Material1Id LEFT JOIN Base_Material AS Material2 ON Material2.MaterialId = WeldJoint.Material2Id LEFT JOIN Base_WeldingMethod AS WeldingMethod ON WeldingMethod.WeldingMethodId=WeldJoint.WeldingMethodId LEFT JOIN Base_WeldingLocation AS WeldingLocation ON WeldingLocation.WeldingLocationId=WeldJoint.WeldingLocationId LEFT JOIN Base_Consumables AS WeldMat ON WeldMat.ConsumablesId=WeldJoint.WeldMatId LEFT JOIN Base_Consumables AS WeldSilk ON WeldSilk.ConsumablesId=WeldJoint.WeldSilkId LEFT JOIN Base_GrooveType AS GrooveType ON GrooveType.GrooveTypeId=WeldJoint.GrooveTypeId LEFT JOIN Base_Components AS Components1 ON Components1.ComponentsId = WeldJoint.PipeAssembly1Id LEFT JOIN Base_Components AS Components2 ON Components2.ComponentsId = WeldJoint.PipeAssembly2Id LEFT JOIN Welder_Welder AS BackingWelder ON BackingWelder.WelderId=WeldJoint.BackingWelderId LEFT JOIN Welder_Welder AS CoverWelder ON CoverWelder.WelderId=WeldJoint.CoverWelderId LEFT JOIN Pipeline_WeldingDaily AS WeldingDaily ON WeldingDaily.WeldingDailyId=WeldJoint.WeldingDailyId LEFT JOIN Base_PipingClass AS pipingClass ON pipingClass.PipingClassId=WeldJoint.PipingClassId LEFT JOIN dbo.WPQ_WPQList wps ON wps.WPQId=WeldJoint.WPQId GO